Serviceline Industrial Sensors
Serviceline Explosion Protection

High temperature identification system OIT500-F113-B12-CB

OIT500-F113-B12-CB
  • High-temperature code carrier up to 500 °C (932 °F)
  • Sturdy and compact design
  • Integrated illumination
  • High operating range
  • Large sensing range
  • High depth of focus

Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH, also apply to Pepperl+Fuchs AG.

Download the complete datasheet as a PDF:


Datasheet excerpt: Technical data of  OIT500-F113-B12-CB

Product Description
Optical high temperature identification system, 200  to  450 mm
General specifications
Light sourceIntegrated LED lightning
Light typeinfrared
SymbologiesHole matrix
Data format: decimal
Data capacity: 6 (numerical)
Orientation: omnidirectional
Read distance200 ... 450 mm
Depth of focus± 50 mm
Reading field330 mm x 250 mm at max. read distance
Evaluation frequency5 Hz
Target velocitytriggered max. 0.5 m/s
Functional safety related parameters
MTTFd51 a
Mission Time (TM)10 a
Diagnostic Coverage (DC)0 %
Indicators/operating means
Operation indicatorLED green: supply
LED green: ready
Function indicatorYellow LED: trigger
Yellow LED: code read
Red LED: pre-fault
Red LED: group error
Electrical specifications
Operating voltage24 V DC ± 15% , PELV
Operating current250 mA without output drivers
Interface
Physical Ethernet
ProtocolTCP/IP
Transfer rate100 MBit/s
Input
Input voltageto be applied externally 24 V ± 15% PELV
Number/Type1 trigger input 2 control unit inputs , optically decoupled
Input currentapprox. 1 mA at 24 V DC
Output
Number/Type1 electronic output, PNP, optically decoupled
Switching voltageto be applied externally 24 V ± 15 % PELV
Switching current100 mA each output
Compliance with standards and directives
Directive conformity
EMC Directive 2004/108/ECEN 61326-1 , EN 61000-6-4
Standard conformity
Noise immunityEN 61326-1
Emitted interferenceEN 61000-6-4:2007/A1:2011
Degree of protectionEN 60529
Approvals and certificates
EAC conformityTR CU 020/2011
Ambient conditions
Ambient temperature0 ... 45 °C (32 ... 113 °F)
Storage temperature-20 ... 60 °C (-4 ... 140 °F)
Mechanical specifications
Degree of protectionIP64
Connection8-pin Harting HAN
RJ-45
2 x 5-pin M12 socket
Supplied ferrite sleeve for suppression of the Ethernet cable
Material
Housingdiecast aluminum powder coated
Massapprox. 4000 g

CAD+CAE: OIT500-F113-B12-CB

CADFile TypeFile Size
3-D model in IGS format / 3-D-Modell im IGS-FormatIGS6551 KB
3-D model in STP format / 3-D-Modell im STP-FormatSTP1608 KB
CAD Portal / CAD PortalLINK---

Approvals+Certificates: OIT500-F113-B12-CB

Statements of complianceCertificate No.File TypeFile Size
EU-Declaration of Conformity / EU-KonformitätserklärungDOC-2494APDF276 KB

Software: OIT500-F113-B12-CB

Software ToolsRelease InfoFile TypeFile Size
Software OITControl for configuration and start of operation / Software OITControl zur Konfiguration und Inbetriebnahme08/2012ZIP25036 KB

Associated Products: OIT500-F113-B12-CB

Accessories

Code carrier for optical high-temperature identification system, stainless steelfa

Cable connector, M12, 4-pin, PVC cablefa
Female cordset, Harting, 8-pin, shielded, PVC cablefa
Connecting cable, RJ-45 to RJ-45, PUR cablefa
Field-attachable "Push-Pull" connectorfa
Field-attachable male connectorfa
Female connector, Harting, 8-pin, field attachablefa
Software for OIT high temperature identification systemfa
Replacement glass for series OIT300, OIT500 and OIT1500fa

Function: OIT500-F113-B12-CB

The OIT* stationary read device is an optical identification system that works using industrial vision methods and is used in automated manufacturing processes. The ambient conditions in automobile construction in particular, for example the cyclical temperature changes, often make the use of read-only tags with electronic components difficult if not impossible.

For the OIT high-temperature identification system, read-only tags of solid metal plates with a perforated matrix are used, which are designed for use at temperatures of up to 500 °C and suitable for high mechanical stress.

Simple installation and commissioning without complicated, time-consuming Teach-In processes enable rapid entry. Pluggable connections for the rapid exchange of devices and a controller with simple command set via the Ethernet interface guarantee simple operation. A scratch-resistant, replaceable quartz glass panel and sturdy metal housing make the OIT* a robust, efficient identification system.