Product Description | ||
---|---|---|
Laser diffuse mode sensor with background evaluation |
General specifications | ||
---|---|---|
Detection range | 7 ... 100 mm | |
Detection range min. | 7 ... 25 mm | |
Detection range max. | 7 ... 100 mm | |
Adjustment range | 25 ... 100 mm | |
Reference target | standard white, 100 mm x 100 mm | |
Light source | laser diode | |
Light type | modulated visible red light | |
Laser nominal ratings | ||
Note | LASER LIGHT , DO NOT STARE INTO BEAM | |
Laser class | 1 | |
Wave length | 680 nm | |
Beam divergence | > 5 mrad d63 < 1 mm in the range of 150 mm ... 250 mm | |
Pulse length | 3 µs | |
Repetition rate | approx. 13 kHz | |
max. pulse energy | 10.4 nJ | |
Black/White difference (6 %/90 %) | < 5 % at 150 mm | |
Diameter of the light spot | < 1 mm at a distance of 60 mm | |
Opening angle | approx. 0.3 ° | |
Ambient light limit | EN 60947-5-2 : 40000 Lux | |
Functional safety related parameters | ||
MTTFd | 560 a | |
Mission Time (TM) | 20 a | |
Diagnostic Coverage (DC) | 0 % | |
Indicators/operating means | ||
Operation indicator | LED green: constantly on - power on flashing (4Hz) - short circuit flashing with short break (1 Hz) - IO-Link mode |
|
Function indicator | LED yellow: constantly on - background detected (object not detected) constantly off - object detected |
|
Control elements | Light-on/dark-on changeover switch | |
Control elements | Sensing range adjuster | |
Electrical specifications | ||
Operating voltage | 10 ... 30 V DC | |
Ripple | max. 10 % | |
No-load supply current | < 20 mA at 24 V supply voltage | |
Protection class | III | |
Interface | ||
Interface type | IO-Link ( via C/Q = pin 4 ) | |
Device profile | Smart Sensor | |
Transfer rate | COM 2 (38.4 kBaud) | |
IO-Link Revision | 1.1 | |
Min. cycle time | 2.3 ms | |
Process data width | Process data input 1 Bit Process data output 2 Bit |
|
SIO mode support | yes | |
Device ID | 0x110703 (1115907) | |
Compatible master port type | A | |
Output | ||
Switching type | The switching type of the sensor is adjustable. The default setting is: C/Q - Pin4: NPN normally open / dark-on, PNP normally closed / light-on, IO-Link |
|
Signal output | 1 push-pull (4 in 1) output, short-circuit protected, reverse polarity protected, overvoltage protected | |
Switching voltage | max. 30 V DC | |
Switching current | max. 100 mA , resistive load | |
Usage category | DC-12 and DC-13 | |
Voltage drop | ≤ 1.5 V DC | |
Switching frequency | 1650 Hz | |
Response time | 300 µs | |
Conformity | ||
Communication interface | IEC 61131-9 | |
Product standard | EN 60947-5-2 | |
Laser safety | EN 60825-1:2014 | |
Approvals and certificates | ||
UL approval | E87056 , cULus Listed , class 2 power supply , type rating 1 | |
FDA approval | IEC 60825-1:2007 Complies with 21 CFR 1040.10 and 1040.11 except for deviations pursuant to Laser Notice No. 50, dated June 24, 2007 | |
Ambient conditions | ||
Ambient temperature | -40 ... 60 °C (-40 ... 140 °F) |
|
Storage temperature | -40 ... 70 °C (-40 ... 158 °F) | |
Mechanical specifications | ||
Housing width | 13.9 mm | |
Housing height | 41.4 mm | |
Housing depth | 18.3 mm | |
Degree of protection | IP67 / IP69 / IP69K | |
Connection | M8 x 1 connector, 3-pin | |
Material | ||
Housing | PC (Polycarbonate) | |
Optical face | PMMA | |
Mass | approx. 10 g |
System | Classcode |
---|---|
ECLASS 11.0 | 27270903 |
ECLASS 10.0.1 | 27270903 |
ECLASS 9.0 | 27270903 |
ECLASS 8.0 | 27270903 |
ECLASS 5.1 | 27270903 |
ETIM 8.0 | EC001821 |
ETIM 7.0 | EC001821 |
ETIM 6.0 | EC001821 |
ETIM 5.0 | EC001821 |
UNSPSC 12.1 | 39121528 |
Technical information | Language | File Type | File Size |
---|---|---|---|
Installation and user instructions for offline parameterization of IO-Link sensors | ENG | 1788 KB | |
Installations-/Benutzeranweisungen für die Offline-Parametrierung von IO-Link-Sensoren | GER | 1764 KB | |
Product information | |||
Product information R10x and R20x Series Standard Housings - All Sensing Modes | ENG | 1783 KB | |
Produktinformation Serien R10x und R20x Alle Funktionsprinzipien - In Standardgehäusen | GER | 1799 KB | |
R101 Series - An Innovative Family of Small Photoelectric Sensors (USA-English) | USA | 322 KB | |
Application report | |||
Application Report - Quality Control in Production Plants | ENG | 803 KB | |
Applikationsbericht - Qualitätskontrolle in Produktionsanlagen | GER | 685 KB |
CAD | File Type | File Size | |
---|---|---|---|
3-D model / 3-D-Modell | STP | 4285 KB | |
CAD Portal / CAD Portal | LINK | --- | |
EPLAN | |||
EPLAN Data Portal / EPLAN Data Portal | LINK | --- | |
EPLAN macro P+F.OBT100-R101-EP-IO-V3-1T-L / EPLAN-Makro P+F.OBT100-R101-EP-IO-V3-1T-L | EDZ | 43 KB |
Statements of compliance | Certificate No. | File Type | File Size |
---|---|---|---|
EU Declaration of Conformity / EU-Konformitätserklärung | DOC-1000E | 308 KB | |
Certificates | |||
Canada USA UL Ordinary Location | 20170306-E87056 | 407 KB |
IO Device Description (IODD) | Release Info | File Type | File Size |
---|---|---|---|
IODD for OBT-1T R100/R101 series / IODD für OBT-1T R100/R101 Serie | 1.00.002 / 2018-08-15 | ZIP | 607 KB |
Software Tools | |||
IO-Link Offline Parameterization Tool / IO-Link Offline-Parametriertool | V1.00.005 / 2021-07-01 | ZIP | 64072 KB |
Accessories | ||||||
---|---|---|---|---|---|---|
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|
||||||
|
The miniature optical sensors are the first devices of their kind to offer an end-to- end solution in a small single standard design — from thru-beam sensor through to a distance measurement device. As a result of this design, the sensors are able to perform practically all standard automation tasks.
The DuraBeam laser sensors are durable and can be used in the same way as a standard sensor.
The use of Multi Pixel Technology gives the standard sensors a high level of flexibility and enables them to adapt more effectively to their operating environment.