Serviceline
Serviceline Industrial Sensors
Serviceline Explosion Protection

Safety Product Selector

Narrow down search result list

Choose your product

Next PageLast Page
Product

Moving presence sensor for automatic doors, SIL 2, certified in accordance with DIN 18650/EN 16005, Exceptional detection reliability, Reliable operation with all floor coverings, Complete protection up to the wall without sensor shutofffa

1-channel isolated barrier, 24 V DC supply (bus powered), Input for 2-wire SMART transmitters and current sources, Output for 4 mA ... 20 mA or 1 V ... 5 V, Low power dissipation, Up to SIL 2 acc. to IEC 61508pa

1-channel isolated barrier, 24 V DC supply (bus powered), Current output up to 650 Ω load, Low power dissipation, Up to SIL 2 acc. to IEC 61508pa

1-channel isolated barrier, 24 V DC supply (bus powered), Dry contact or NAMUR inputs, Usable as signal splitter (1 input and 2 outputs), Relay contact output, Fault relay contact output, Line fault detection (LFD), Up to SIL 2 acc. to IEC 61508pa

2-channel isolated barrier, 24 V DC supply (bus powered), Dry contact or NAMUR inputs, 2 relay contact outputs, Line fault detection (LFD), Up to SIL 2 acc. to IEC 61508pa

1-channel isolated barrier, 24 V DC supply (loop powered), Output 45 mA at 12 V DC, Up to SIL 3 acc. to IEC 61508pa

1-channel isolated barrier, 24 V DC supply (bus powered), 2-wire SMART transmitters or current sources, Output for 4 mA ... 20 mA or 1 V ... 5 V, Line fault detection (LFD), Up to SIL 2 acc. to IEC 61508pa

2-channel isolated barrier, 24 V DC supply (bus powered), 2-wire SMART transmitters or current sources, Usable as signal splitter (1 input and 2 outputs), Dual output 4 mA ... 20 mA or 1 V ... 5 V, Line fault detection (LFD), Up to SIL 2 acc. to IEC 61508pa

2-channel isolated barrier, 24 V DC supply (bus powered), 2-wire SMART transmitters or current sources, Usable as signal splitter (1 input and 2 outputs), Dual output 4 mA ... 20 mA, current sink, Line fault detection (LFD), Up to SIL 2 acc. to IEC 61508pa

2-channel isolated barrier, 24 V DC supply (bus powered), Current output up to 750 Ω load, SMART I/P and valve positioners, Line fault detection (LFD), Up to SIL 2 acc. to IEC 61508pa
Next PageLast Page
Absolute positioning systems safePXV and safePGV

SIL 3/PL e with One Sensor

For the first time, the new absolute positioning systems safePXV and safePGV realize safety level SIL 3/PL e with a single sensor …

K-System Safety Relays

Triple Protection

Pepperl+Fuchs is setting a new level of reliability with newly developed safety relays. With multi-redundant switching contacts, the interface module from the tried-and-tested K-System provides reliable and safety-related activation and deactivation for applications in accordance with IEC61508 up to SIL 3.