Serviceline Industrial Sensors
Serviceline Explosion Protection

Read/write head IPH-F90A-V1

IPH-F90A-V1
  • Connection via V1 (M12 x 1) plug connection
  • Dual-LED for function display
  • Degree of protection IP67
  • For connection to IDENTControl control interface

Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.

Download the complete datasheet as a PDF:


Datasheet excerpt: Technical data of  IPH-F90A-V1

Product Description
LF read/write head for IDENTControl
General specifications
Operating frequency125 kHz
Transfer rate2 kBit/s
Sensing range
Read distance3 ... 90 mm (with transponder IPC03-50P at 25°C)
Write distance3 ... 80 mm (with transponder IPC03-50P at 25°C)
Widthmax. 140 mm
UL File NumberE87056
Functional safety related parameters
MTTFd700 a
Mission Time (TM)10 a
Diagnostic Coverage (DC)0 %
Indicators/operating means
LED green/yellowgreen: power on
green flashing: read/write attempt performed
yellow: data carrier detected
Electrical specifications
Power consumption≤ 1.2 W
Supplyfrom the IDENTControl
Mag. Field strength< 27.3 dBµA/m at 10 m
Directive conformity
Radio equipment
Directive 2014/53/EUEN 301489-1
EN 301489-3
EN 300330
EN 62368-1
EN 50364
RoHS
Directive 2011/65/EU (RoHS)EN 50581
Standard conformity
Degree of protectionEN 60529
RFIDISO/IEC 18000-2
Ambient conditions
Ambient temperature-25 ... 55 °C (-13 ... 131 °F)
Storage temperature-40 ... 55 °C (-40 ... 131 °F)
Mechanical specifications
Degree of protectionIP67
Connectionconnector M12 x 1
Material
HousingABS
Encapsulation compoundWEVO 403FL/300
Installation
Distance between two headsMultiplex on: ≥ 100 mm
Multiplex off: ≥ 550 mm
Massapprox. 180 g

Approvals+Certificates: IPH-F90A-V1

Statements of complianceCertificate No.File TypeFile Size
EU-Declaration of conformity / EU-KonformitätserklärungDOC-2874CPDF162 KB
Certificates
Australia Declaration of ConformityACMA Supplier's declaration of conformityPDF204 KB
US CA ULE87056LINK---

Associated Products: IPH-F90A-V1

Accessories

Control interface unit IDENTControl with PROFIBUS DP interfacefa

IDENTControl control interface with Ethernet interface for TCP/IP, PROFINET, EtherNet/IP, and MODBUS TCP protocolsfa

Control interface unit IDENTControl Compactwith serial interface RS-232 and RS-485fa

Control interface unit IDENTControl Compact with interface for PROFIBUS DPfa

IDENTControl Compact control interface with Ethernet interface for TCP/IP, PROFINET, EtherNet/IP, and MODBUS TCP protocolsfa

Control interface unit IDENTControl Compact with EtherCAT interfacefa

Code carrierfa

Data carrierfa

Data carrierfa

Data carrierfa

Cordset M12 socket straight to M12 plug angled A-coded, 4-pin, PUR cable grey, shieldedfa

Cordset M12 socket straight to M12 plug angled A-coded, 4-pin, PUR cable grey, shieldedfa

Cordset M12 socket straight to M12 plug angled A-coded, 4-pin, PUR cable grey, shieldedfa

Data carrierfa

Code carrierfa

Code carrierfa
Data carrierfa
Visit the RFID Hub