1-channel isolated barrier, 24 V DC supply (bus powered), Input for 2-wire SMART transmitters and current sources, Signal splitter (1 input and 2 outputs), Dual output 0/4 mA ... 20 mA or 0/1 V ... 5 V, Up to SIL 2 (SC 3) acc. to IEC/EN 61508, Housing width: 12.5 mm, Number of channels: 1-channel, HART communication, Safety Integrity Level (SIL): SIL 2, Systematic capability (SC): SC 3, Rated voltage: 20 ... 30 V DC bus powered via Termination Board, Field device: 2-wire transmitterpa
2-channel isolated barrier, 24 V DC supply (bus powered), Dry contact or NAMUR inputs, 2 passive transistor outputs, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 (SC 3) acc. to IEC/EN 61508, Housing width: 12.5 mm, Number of channels: 2-channel, Safety Integrity Level (SIL): SIL 2, Systematic capability (SC): SC 3, Rated voltage: 19 ... 30 V DC bus powered via Termination Board, Field device: NAMUR sensor, Field device [2]: volt-free contact, Line fault detectionpa
1-channel isolated barrier, 24 V DC supply (bus or loop powered), Output 45 mA at 12 V DC, Line fault transparency (LFT), Test pulse immunity, Up to SIL 3 acc. to IEC/EN 61508, Housing width: 12.5 mm, Number of channels: 1-channel, Line fault transparency, Filter, Safety Integrity Level (SIL): SIL 3, Systematic capability (SC): SC 3, Rated voltage: 19 ... 30 V bus powered via Termination Board 19 ... 30 V loop powered via input , reverse polarity protected, Type: logic inputpa
1-channel isolated barrier, 24 V DC supply (bus or loop powered), Output 45 mA at 12 V DC, Line fault transparency (LFT), Test pulse immunity, Housing width 12.5 mm, Up to SIL 3 acc. to IEC/EN 61508, Housing width: 12.5 mm, Number of channels: 1-channel, Line fault transparency, Safety Integrity Level (SIL): SIL 3, Systematic capability (SC): SC 3, Rated voltage: 19 ... 30 V DC loop powered, Type: logic input, Type [2]: field device supply, Test pulse immunity, Field device: 1 x Valvepa
Pepperl+Fuchs offers an ultrasonic sensor for safe operation of automated guided transport systems in hospitals ... round corners or transitioning into the supply shaft. Since the system is an overhead conveyor, the solution must ensure that the head and shoulder area of personnel in the lane is detected to prevent injury through collisions. The Solution The USi ...
See Overview: Our ultrasonic sensors present the ideal solution for non-contact position and distance measurement in all industrial areas Contact us for enquiries! ... of the sensors. NEW! Reliable Safeguarding in Accordance with Category 3 PL d USi-safety Ultrasonic Sensor System The USi-safety ultrasonic sensor system is breaking new ground for safety applications —whether in challenging, dusty environments or in outdoor ...
See Overview: Pepperl+Fuchs diffuse mode and retroreflective mode ultrasonic sensors place the transmitter and receiver in the same housing ... with Category 3 PL d USi-safety Ultrasonic Sensor System The USi-safety ultrasonic sensor system is breaking new ground for safety applications —whether in challenging, dusty environments or in outdoor areas. Machines and vehicles can be reliably protected ...