General specifications |
Switching element function | Analog current or voltage output, programmable |
Object distance | 0.5 ... 3 mm , recommended: 1.5 mm |
Measurement range | 0 ... 80 mm |
Linearity range | 1 ... 79 mm |
Nominal ratings |
Operating voltage | 12 ... 30 V DC (13 ... 30 V when analog voltage output is parameterized) |
Reverse polarity protection | reverse polarity protected |
Linearity error | within measuring range: ± 0.8 mm within linearity range: ± 0.4 mm |
Repeat accuracy | ± 0.1 mm |
Resolution | 50 µm |
Temperature drift | ± 0.5 mm (-25 °C ... 70 °C) |
No-load supply current | ≤ 40 mA |
Operating voltage indicator | LED green |
Functional safety related parameters |
MTTFd | 311 a |
Mission Time (TM) | 20 a |
Diagnostic Coverage (DC) | 0 % |
Indicators/operating means |
LED S3 | Damping element in the configured analog measuring range |
LED STATUS | Status display LED, green/red (Power on, communication/error, missing damping element) |
Interface |
Interface type | IO-Link (via C/Q = Pin 4) |
IO-Link revision | 1.1 |
Device profile | Smart Sensor |
Device ID | 0x200301 (2097921) |
Transfer rate | COM2 (38.4 kBit/s) |
Value range | 0000h ... 6400h |
Min. cycle time | 2.3 ms |
Process data width | Process data input: 16 Bit Process data output: none |
SIO mode support | yes |
Compatible master port type | A |
Analog output |
Output type | current output 4-20 mA voltage output 0 - 5 V DC 0 ... 10 V DC , programmable |
Load resistor | current output: ≤ 400 Ω voltage output: ≥ 1000 Ω |
Short-circuit protection | voltage output: current limit |
Compliance with standards and directives |
Standard conformity | |
| Standards | EN 60947-5-2:2007 EN 60947-5-2/A1:2012 IEC 60947-5-2:2007 IEC 60947-5-2 AMD 1:2012 EN 60947-5-7:2003 EN61131-9:2013 IEC 60947-5-7:2003 IEC 61131-9:2013 |
Approvals and certificates |
UL approval | cULus Listed, Class 2 Power Source, Type 1 enclosure |
Marine approval | DNVGL TAA00001V2 |
Ambient conditions |
Ambient temperature | -25 ... 85 °C (-13 ... 185 °F) |
Mechanical specifications |
Connection type | 5-pin, M12 x 1 connector |
Degree of protection | IP67 / IP69K |
Material | |
| Housing | PBT, stainless steel 1.4571 , brass, nickel-plated |
| Target | mild steel, e. g. 1.0037, SR235JR (formerly St37-2) |
Mass | 83 g |
Dimensions | |
| Height | 40 mm |
| Width | 23 mm |
| Length | 95.1 mm |