Terminal Module F-KDR-Ex2

F-KDR-Ex2
  • 2-channel
  • Dry contact input
  • Reduces field wiring by 50%
  • Supports 2:1 technology

请注意:所有以Pepperl + Fuchs GmbH或Pepperl + Fuchs AG名义发行的产品相关文件,例如证书,合格声明等,同样适用于Pepperl + Fuchs SE。

將完整的規格書下載為PDF:


產品規格摘要:的技術資料  F-KDR-Ex2

產品描述
Terminal module for mechanical contacts
Conformity
Degree of protectionIEC 60529:2001
Mechanical specifications
Degree of protectionIP20
Connectionspring terminals
Core cross section0.08 ... 2.5 mm2
Massapprox. 100 g
Dimensions6.5 x 90.5 x 68.5 mm (0.2 x 3.6 x 2.7 inch) (W x H x D)
Height90.5 mm
Width6.5 mm
Depth68.5 mm
Mountingon 35 mm DIN mounting rail acc. to EN 60715:2001
Data for application in connection with hazardous areas
CertificateDOC-0097 , see instruction manuals
Temperature classT6 T6 T4
Voltage≤ 16 V ≤ 16 V ≤ 16 V
Current≤ 14 mA ≤ 21 mA ≤ 52 mA
Power≤ 35 mW ≤66 mW ≤ 169 mW
Ambient temperature72 °C 66 °C 80 °C
Internal capacitance0 F
Internal inductance0 H
General information
Supplementary informationObserve the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com.

Classifications

SystemClasscode
ECLASS 13.027219090
ECLASS 12.027219090
ECLASS 11.027219290
ECLASS 10.0.127219290
ECLASS 9.027219290
ECLASS 8.027219290
ECLASS 5.127279290
ETIM 9.0EC002637
ETIM 8.0EC003015
ETIM 7.0EC003015
ETIM 6.0EC003015
ETIM 5.0EC003015
UNSPSC 12.139121410

Details: F-KDR-Ex2

Product Documentation: F-KDR-Ex2

Language Selection:
Brief Instructions語言檔案類型檔案尺寸
Instruction Manual F-KD(R)-Ex2 / Betriebsanleitung F-KD(R)-Ex2ALLPDF95 KB
Safety and Security Documentation
Instruction manualENGPDF154 KB

Approvals: F-KDR-Ex2

Language Selection:
Declaration of Conformity證書號碼語言檔案類型檔案尺寸
Declaration of Conformity Simple Apparatus / Konformitätserklärung Einfaches BetriebsmittelDOC-0097ALLPDF44 KB

相關產品: F-KDR-Ex2

Accessory of
4-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, 50 % less wiring, 2:1 technology, Relay contact output, Line fault detection (LFD), Reversible mode of operation, Housing width: 20 mm, Number of channels: 4-channel, 2:1 Method, Rated voltage: 19 ... 30 V DC, Field device: NAMUR sensor, Field device [2]: volt-free contact, Line fault detection, Type: 4 x relay (NO contact), Reversible mode of operationpa
Safety Products Selector

Choose from various selection criteria like safety integrity level, performance level, device function, and signal type and find the SIL/PL assessed device that you are looking for.