System components |
Emitter | OBE12M-R101-S-IO-0,3M-V1 |
Receiver | OBE12M-R101-2EP-IO-0,3M-V1 |
General specifications |
Effective detection range | 0 ... 12 m |
Threshold detection range | 15 m |
Light source | LED |
Light type | modulated visible red light |
LED risk group labelling | exempt group |
Diameter of the light spot | approx. 65 mm at a distance of 1 m |
Opening angle | 3.7 ° |
Ambient light limit | EN 60947-5-2 : 30000 Lux |
Functional safety related parameters |
MTTFd | 462 a |
Mission Time (TM) | 20 a |
Diagnostic Coverage (DC) | 0 % |
Indicators/operating means |
Operation indicator | LED green: constantly on - power on flashing (4Hz) - short circuit flashing with short break (1 Hz) - IO-Link mode |
Function indicator | Yellow LED: Permanently lit - light path clear Permanently off - object detected Flashing (4 Hz) - insufficient operating reserve |
Control elements | Receiver: light/dark switch |
Control elements | Receiver: sensitivity adjustment |
Parameterization indicator | IO link communication: green LED goes out briefly (1 Hz) |
Electrical specifications |
Operating voltage | 10 ... 30 V DC |
Ripple | max. 10 % |
No-load supply current | Emitter: ≤ 14 mA Receiver: ≤ 13 mA at 24 V supply voltage |
Protection class | III |
Interface |
Interface type | IO-Link ( via C/Q = pin 4 ) |
IO-Link revision | 1.1 |
Device ID | Emitter: 0x110401 (1115137) Receiver: 0x110301 (1114881) |
Transfer rate | COM2 (38.4 kBit/s) |
Min. cycle time | 2.3 ms |
Process data width | Emitter: Process data output: 2 Bit Receiver: Process data input: 2 Bit Process data output: 2 Bit |
SIO mode support | yes |
Compatible master port type | A |
Input |
Test input | emitter deactivation at +UB |
Output |
Switching type | The switching type of the sensor is adjustable. The default setting is: C/Q - Pin4: NPN normally open / dark-on, PNP normally closed / light-on, IO-Link /Q - Pin2: NPN normally closed / light-on, PNP normally open / dark-on |
Signal output | 2 push-pull (4 in 1) outputs, short-circuit protected, reverse polarity protected, overvoltage protected |
Switching voltage | max. 30 V DC |
Switching current | max. 100 mA , resistive load |
Usage category | DC-12 and DC-13 |
Voltage drop | ≤ 1.5 V DC |
Switching frequency | 1000 Hz |
Response time | 0.5 ms |
Compliance with standards and directives |
Directive conformity | |
| EMC Directive 2004/108/EC | EN 60947-5-2:2007+A1:2012 |
Standard conformity | |
| Product standard | EN 60947-5-2:2007+A1:2012 IEC 60947-5-2:2007 + A1:2012 |
| Standards | UL 60947-5-2: 2014 IEC 61131-9:2013 EN 62471:2008 EN 61131-9:2013 |
Approvals and certificates |
UL approval | E87056 , cULus Listed , class 2 power supply , type rating 1 |
Ambient conditions |
Ambient temperature | -40 ... 60 °C (-40 ... 140 °F) , fixed cable -25 ... 60 °C (-13 ... 140 °F) , movable cable not appropriate for conveyor chains |
Storage temperature | -40 ... 70 °C (-40 ... 158 °F) |
Mechanical specifications |
Degree of protection | IP67 / IP69 / IP69K |
Connection | 300 mm fixed cable with M12 x 1, 4-pin connector |
Material | |
| Housing | PC (Polycarbonate) |
| Optical face | PMMA |
Mass | Emitter: approx. 10 g receiver: approx. 10 g |
Dimensions | |
| Height | 33.8 mm |
| Width | 13.9 mm |
| Depth | 18.3 mm |
Cable length | 0.3 m |