ICA-4IO-2M4-G20-B22A-P18 Motor Roller System Module

G20 MDR system module with 4 digital inputs/outputs and 2 connections for MDRs

Key Benefits at a Glance

  • Connections for 24 V or 48 V DC roller motors
  • Inputs for 2- and 3-wire sensors
  • Electronic PNP outputs
  • Function indicator for motors, inputs and outputs
  • Mounting directly in the support profile

Show more

In stock6 098,00 CZK Net price—your individual price will be shown during checkout process.
Product Compliance: Europe – CE
Product Compliance: USA - cULus
Note

All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.

EN
  • EN
  • DE
  • FR

Technical data of ICA-4IO-2M4-G20-B22A-P18

Compatible roller motorsInterroll EC310
Interroll EC5000 24 V AI (20 W / 35 W / 50 W)
Interroll EC5000 48 V AI (20 W / 35 W / 50 W)
Rulmeca BL3
Itoh Denki PM500XK
Itoh Denki PM500XC
PULSEROLLER Senergy-IDC
MTA MRD50 (A interface, 24 V to 40 W)
MTA MRD50 (A interface, 48 V to 44 W)
WWL R-*-H + CE23XX
Conveline RM50
Mambaroll Built-In Drive Roller 50
UniDrive ONE
LED indicationZone 1: MOT, IO1, IO2, X
Zone 2: MOT, IO1, IO2, X
L-A, L-B, PWR
Auxiliary voltageUPWR18 ... 56 V DC PELV Max. 10 A
Current limitation of the supply max. 30 A
For UL: Z-type miniature circuit breaker in accordance with UL 1077, max. 20 A, required
Operating voltageUB15 ... 30 V DC, PELV
Powered from ICE-EP2-G20-4B22A-P17
No-load supply currentI0≤ 40 mA
Operating currentIBmax. 3 A
Interface typeproprietary system interface
Number/Type4 Inputs for 3-wire sensors (PNP), DC (Zone 1: IO1, IO2; Zone 2: IO1, IO2)
Supplyfrom G20 Motor Roller System Module via L-A
Current loading capacity200 mA per connection in Zone 1 (IO1, IO2) and Zone 2 (IO1, IO2) , overload and short-circuit protected
Input current≤ 5 mA (limited internally)
Switching pointType 3 according to IEC 61131-2
Number/Type4 electronic outputs, PNP (Zone 1:IO1, IO2; Zone 2: IO1, IO2), overload proof and short-circuit proof
Supplyfrom G20 Motor Roller System Module via L-A
Current200 mA per output
Number/Type2 outputs for DC roller motors (Zone 1: MOT, Zone 2: MOT)
Supplyvia UPWR
Current loading capacity3.5 A (continuous), 5 A (< 2 s), max. 7.5 A (< 0.3 s) per motor
Total current (continuous) max. 7 A per device
Overload protectionFuse 4 A, I2t = 122.5 A2s per motor
Signal levelSpeed: US = 0.3 … 10 V in no-load operation
Ri = 5.6 kΩ, RLOAD ≥ 35 kΩ
Direction of rotation: Digital output PNP
UD low = high resistance
UD high ≥ 12 V
Ri = 5.6 kΩ, RLOAD ≥ 15 kΩ
Fault levelMotor fault: Digital input NPN
0 (no error) ≥ 125 µA
1 (error) ≤ 25 µA
Electromagnetic compatibility
Directive 2014/30/EUEN 61326-1:2013
EN 55011:2016
Degree of protectionEN 60529:2000
InputEN 61131-2:2007
Emitted interferenceEN 61000-6-4:2007
Noise immunityEN 61000-6-2:2005
UL approval
Applicationfor use in NFPA 79 applications
UL File NumberE223772
Ambient temperature-25 ... 60 °C (-13 ... 140 °F)
Storage temperature-40 ... 85 °C (-40 ... 185 °F)
Relative humidity85 % non-condensing
Climatic conditionsFor indoor use only
Altitude≤ 5000 m above MSL
Shock and impact resistance30 g, 11 ms in 6 spatial directions, 3 shocks 10 g, 16 ms in 6 spatial directions,
1000 shocks
Vibration resistance0.75 mm / 5 g 5 ... 500 Hz
Pollution degree3
Degree of protectionIP67 according to EN 60529
Connection24 V/48 V power (PWR): Piercing technology, black or gray flat cable
L-A; L-B: M12 round plug connector in accordance with EN 61076-2-101, LF type (4-pin, socket contacts, screw-locking, A-coded)
Mating connector: LM type or similar
Inputs/outputs (IO), motors (MOT): M8 round plug connector in accordance with EN 61076-2-104
IO: LF type (4-pin, bushing contacts, screw-locking, A-coded)
Female connector: LM type or similar
MOT: NF type (5-pin, bushing contacts, snap-locking, B-coded)
Female connector: NM type or similar
Mass310 g
Dimensions
Height27.5 mm
Width131.5 mm
Length54 mm
Mounting2 clips with ∅ 8 mm drill hole
The module must be secured to a solid, continuous surface using the two lugs
Cable length1.5 m (L-A, L-B)
0.8 m (Zone 1, Zone 2: IO)
0.4 m (Zone 1, Zone 2: MOT)
NoteThe flat cable routing is designed for 100 actuation cycles
General Notes