IO-Link Safety
The Bridge Between Functional Safety and Standard Automation
What has long been thought of as separate is now growing together: The new IO-Link Safety standard bridges the gap between functional safety and standard automation.
The combination of IO-Link Safety and IO-Link now provides a common, consistent communication basis right down to field level. This eliminates system discontinuities, reduces complexity, and supports the seamless integration of safety-related sensor technology and actuators with standard components in a single architecture. The result is transparent, flexible and future-oriented systems with significantly more efficient engineering and higher availability.
This is made possible by consistent standardization: Developed under the umbrella of PROFIBUS & PROFINET International (PI) in the IO-Link community and defined in the IEC 61131-9 and IEC 61139-2 standards, IO-Link Safety meets the highest safety requirements up to SIL 3 (IEC 61508 / IEC 62061) and PL e, Cat. 4 (EN ISO 13849-1).
Find out more about how IO-Link Safety works and how you too can benefit from this major evolutionary leap.

Black Channel Communication: Safe Data via a Common Channel
IO-Link Safety can be integrated into different safety architectures and allows safe and non-safe signals to be transmitted together on one line.
Functional safety in architectures based on IO-Link Safety is ensured by the black channel principle: Here, the actual signal path is not monitored ("black channel"), but possible transmission errors are reliably detected between the IO-Link Safety master and device using mechanisms such as checksums, time monitoring and sequence checks, and unsafe states are avoided. Thanks to this implementation between the IO-Link Safety master and device, IO-Link Safety can be used independently of the Functional Safety Communication Profile (FSCP, e.g. PROFIsafe) used and thus across different fieldbus systems.
As shown in the diagram, safety and standard data are transmitted in parallel while remaining logically separated from each other. As a result, despite the integrative overall concept, safe communication up to SIL 3 and PL e remains clearly defined, while additional data is available for diagnostics and IIoT applications.

Clear Structure Down to the Connector: The Pin Assignment of IO-Link Safety
IO-Link Safety uses standard IO-Link mechanisms such as the established M12 plug connection and a standardized pinout for the joint transmission of safe and non-safe signals. As shown in the graphic, the supply voltage is applied to pin 1 and pin 3. The C/Q wire on pin 4 is used to transmit the IO-Link Safety communication including the safety data.
As an alternative to operation as an IO-Link Safety device, sensors and actuators with an IO-Link Safety interface—similar to SIO mode in standard IO-Link—can first be configured via the communication interface and then operated like a classic OSSD with conventional safety technology. In this case, safe signal transmission on pin 4 is supplemented by an additional signal path on pin 2. Both paths are used together (OSSD1e and OSSD2e) to ensure robust and fail-safe transmission. This mode is referred to as OSSDe (OSSD equivalent).
For users, this results in a clearly structured interface: standardized M12 cables remain usable, while safe and non-safe data is routed via a common connector. This reduces wiring effort, simplifies installation and service, and ensures consistent and traceable data and power transmission right down to field level.
Safety Is Changing ...
Functional safety is constantly evolving—from classic, often separate solutions to increasingly integrated and flexible architectures. Get an insight into today's common architecture models and find out why IO-Link Safety is superior to all existing approaches.