Power supply for 24 V, Permits vertical or horizontal mounting in Zone 2, Use three power supplies for redundancy, Galvanic isolation to mains, Voltage: 5.4 V DC +/- 5% , , 12 V DC + 4/- 2%
8-channel, Inputs Ex ia, Mounting in Zone 2, Class I/Div.2 or in the safe area, Dry contact or NAMUR inputs, Explosion protection: Ex ia, Connection: NAMUR sensor, Connection [2]: volt-free contact
4-channel, Inputs Ex ia, Mounting in Zone 2, Class I/Div.2 or in the safe area, Power supply for 2-wire transmitters with 4 mA ... 20 mA, Explosion protection: Ex ia, Field device: pressure converter, Field device [2]: flow converter, Field device [3]: level converter, Field device [4]: Temperature Converter, Connection: 2-wire transmitter, Connection [2]: 3-wire transmitter, Connection [3]: 4-wire transmitter, HART communication
2-channel, Outputs Ex ia, Mounting in Zone 2, Class I/Div.2 or in the safe area, Line fault detection switched on and off, Explosion protection: Ex ia
4-channel, Inputs Ex ia, Outputs Ex ia, Analog input, digital input,, analog output, digital output, Mounting in Zone 2, Class I/Div.2 or in the safe area
Interface between the I/O modules and the PCS/PLC, Com unit for 80 analog or 184 digital channels, Communication via PROFIBUS DP, Mounting in Zone 2, Class I/Div.2 or in the safe area, Fieldbus type: PROFIBUS DP/DP-V1
1-channel, Input Ex ia, Mounting in Zone 2, Class I/Div.2 or in the safe area, Power supply for 2- or 3-wire transmitters with 4 mA ... 20 mA, Explosion protection: Ex ia, Field device: pressure converter, Field device [2]: flow converter, Field device [3]: level converter, Field device [4]: Temperature Converter, Connection: 2-wire transmitter, Connection [2]: 3-wire transmitter, Connection [3]: 4-wire transmitter, HART communication
4 channels, Inputs Ex ia, Mounting in Zone 2, Class I/Div.2 or in the safe area, Converter for 2-, 3- and 4-wire RTDs (Pt100 ... Pt1000), slide wire sensors etc., Explosion protection: Ex ia, Field device: resistance thermometer, Field device [2]: slide-wire sensors, Field device [3]: potentiometer, Connection: 2-wire sensor, Connection [2]: 3-wire sensor, Connection [3]: 4-wire sensor
Interface between the I/O modules and the PCS/PLC, Com unit for 80 analog or 184 digital channels, Communication via MODBUS RTU, Mounting in Zone 2, Class I/Div.2 or in the safe area, Fieldbus type: MODBUS RTU
4-channel, Inputs Ex ia, Outputs Ex ia, Installation in suitable enclosures in Zone 1, Module can be exchanged under voltage (hot swap), Explosion protection: Ex ia, Field device: pressure converter, Field device [2]: flow converter, Field device [3]: level converter, Field device [4]: Temperature Converter, Connection: 2-wire transmitter, HART communication
Active termination of the fieldbus and passive termination of the service bus, Installation in suitable enclosures in Zone 1, Module can be exchanged under voltage in Zone 1 (hot swap; be aware bus operation may be affected)
8-channel, Inputs Ex ia, Installation in suitable enclosures in Zone 1, Module can be exchanged under voltage (hot swap), Explosion protection: Ex ia, Connection: NAMUR sensor, Connection [2]: volt-free contact
4-channel, Inputs Ex ia, Installation in suitable enclosures in Zone 1, Module can be exchanged under voltage (hot swap), Explosion protection: Ex ia, Field device: pressure converter, Field device [2]: flow converter, Field device [3]: level converter, Field device [4]: Temperature Converter, Connection: 2-wire transmitter, Connection [2]: 3-wire transmitter, Connection [3]: 4-wire transmitter, HART communication
Interface between the I/O modules and the PCS/PLC, Com unit for 80 analog or 184 digital channels, Communication via PROFIBUS DP, Installation in suitable enclosures in Zone 1, Fieldbus type: PROFIBUS DP/DP-V1
Power supply for 24 V DC, Installation in suitable enclosures in Zone 1, Module can be exchanged under voltage (hot swap), Voltage: 5.4 V DC +/- 5% , , 12 V DC + 4/- 2%
4 channels, Inputs Ex ia, Mounting in Zone 2, Class I/Div.2 or in the safe area, Converter for thermocouples and mV-signals, Explosion protection: Ex ia, Compensation (reference junction CJC): internal cold junction compensation or external cold junction, Field device [2]: Thermocouple, Field device [4]: mV source, Compensation (reference junction CJC): internal cold junction compensation or external cold junction
Interface between the I/O modules and the PCS/PLC, Com unit for 80 analog or 184 digital channels, Communication via MODBUS TCP, Mounting in Zone 2, Class I/Div.2 or in the safe area, Fieldbus type: MODBUS TCP
4-channel, Inputs Ex ia, Installation in suitable enclosures in Zone 1, Module can be exchanged under voltage (hot swap), Explosion protection: Ex ia, Field device: resistance thermometer, Field device [2]: slide-wire sensors, Field device [3]: potentiometer, Connection: 2-wire sensor, Connection [2]: 3-wire sensor, Connection [3]: 4-wire sensor
1-channel, Input Ex ia, Mounting in Zone 2, Class I/Div.2 or in the safe area, Input for frequency, counter, direction of rotation, Explosion protection: Ex ia, Function: Counter , Function [2]: frequency, Function [3]: direction of rotation, Connection: NAMUR sensor, Connection [2]: volt-free contact
Spring terminal, For LB and FB modules, 6-pole, Labeled 1 ... 6, Color blue, For Ex ia or Ex ib applications, Construction type: spring terminal
Spring terminal, For LB and FB modules, 8-pole, Labeled 1 ... 8, Color blue, For Ex ia or Ex ib applications, Construction type: spring terminal
Front screw terminal, For LB and FB modules, 8-pole, Labeled 1 ... 8, Color blue, For Ex ia or Ex ib applications, Construction type: front screw terminal
Front screw terminal, For LB and FB modules, 2 x 8-pole, Labeled 1 ... 8 and 9 ... 16, Color blue, For Ex ia or Ex ib applications, Construction type: front screw terminal
Spring terminal, For LB and FB modules, 2 x 8-pole, Labeled 1 ... 8 and 9 ... 16, Color blue, For Ex ia or Ex ib applications, Construction type: spring terminal
Spring terminal, For LB modules, 8-pole, Color blue, For Ex ia or Ex ib applications, For wire end ferrules without plastic sleeve only, Construction type: spring terminal
Front screw terminal, For LB and FB modules, 6-pole, Labeled 1 ... 6, Color blue, For Ex ia or Ex ib applications, Construction type: front screw terminal
4-channel, Inputs with plug-in Ex e terminals, Installation in suitable enclosures in Zone 1, Module can be exchanged under voltage (hot swap), Explosion protection: Ex e connection, Field device: pressure converter, Field device [2]: flow converter, Field device [3]: level converter, Field device [4]: Temperature Converter, Connection: 2-wire transmitter, HART communication
Backplane for LB-System, For PROFIBUS DP, PROFIBUS DP V1, PROFINET, and MODBUS RTU, Max. 22 slots for I/O modules, 5 SIL 2 output shutdown segments, Number of modules: 22, Redundancy, Fieldbus type: PROFIBUS DP/DP-V1, PROFINET or MODBUS RTU , depends on bus coupler, Redundancy
Backplane for LB-System, For MODBUS TCP/IP, Max. 22 slots for I/O modules, Redundancy (field bus and power supply), Number of modules: 22, Redundancy, Fieldbus type: MODBUS TCP, Redundancy
Backplane for LB-System, For PROFIBUS DP, PROFIBUS DP V1, PROFINET, and MODBUS RTU, Max. 8 slots for I/O modules, Mounting in Zone 2, Class I/Div.2 or in the safe area, Number of modules: 8, Fieldbus type: PROFIBUS DP/DP-V1, PROFINET or MODBUS RTU , depends on bus coupler
Backplane for LB-System, Fieldbus type determined by base backplane, Max. 24 slots for I/O modules, 5 SIL 2 output shutdown segments, Number of modules: 24, Redundancy, Fieldbus type: PROFIBUS DP/DP-V1, PROFINET or MODBUS RTU/TCP , depending on the base backplane, Redundancy
Backplane for LB-System, For MODBUS TCP/IP, Max. 16 slots for I/O modules, Mounting in Zone 2, Class I/Div.2 or in the safe area, Number of modules: 16, Fieldbus type: MODBUS TCP
Backplane for LB-System, Fieldbus type determined by base backplane, Max. 16 slots for I/O modules, Mounting in Zone 2, Class I/Div.2 or in the safe area, Number of modules: 16, Fieldbus type: PROFIBUS DP/DP-V1, PROFINET or MODBUS RTU/TCP , depending on the base backplane
Multi range power supply 90 ... 253 V AC, Suitable for the supply of 24 I/O modules and 1 bus coupler, Use two power supplies for redundancy, Installation in suitable enclosures in Zone 1, Voltage: 5.4 V DC +/- 5% , , 12 V DC +/- 3%
1-channel, 1 digital output, 2 digital inputs, Mounting in Zone 2, Class I/Div.2 or in the safe area, Inputs and output Ex ia, Explosion protection: Ex ia
4-channel, Inputs Ex ia, Mounting in Zone 2, Class I/Div.2 or in the safe area, Power supply for 2-wire transmitters with 4 mA ... 20 mA, Explosion protection: Ex ia, Field device: pressure converter, Field device [2]: flow converter, Field device [3]: level converter, Field device [4]: Temperature Converter, Connection: 2-wire transmitter, HART communication
4-channel, Outputs Ex ia, Mounting in Zone 2, Class I/Div.2 or in the safe area, Module can be exchanged under voltage, Explosion protection: Ex ia, SIL/IEC 61508, Field device: Proportional Valve, Field device [2]: I/P converters, Field device [3]: on-site display
Communication via PROFINET, Mounting in Zone 2, Class I/Div.2 or in the safe area, Interface between the I/O modules and the PCS/PLC, Non-volatile memory for configuration and parameter settings, Fieldbus type: PROFINET
2-channel, Outputs Ex ia, Installation in suitable enclosures in Zone 1, Module can be exchanged under voltage (hot swap), Explosion protection: Ex ia, Field device: Solenoid Valve, Field device [2]: audible alarm, Field device [3]: visual alarm
Backplane for LB-System, For PROFIBUS DP, PROFIBUS DP V1, PROFINET, and MODBUS RTU, Max. 16 slots for I/O modules, Mounting in Zone 2, Class I/Div.2 or in the safe area, Number of modules: 16, Fieldbus type: PROFIBUS DP/DP-V1, PROFINET or MODBUS RTU , depends on bus coupler
Base backplane for FB system, Max. 24 slots for I/O modules, Installation in Zone 1, For PROFIBUS, MODBUS RTU or MODBUS TCP
1-channel, Input Ex ia, Mounting in Zone 2, Class I/Div.2 or in the safe area, Converter for thermocouples and mV-signals, Explosion protection: Ex ia, Compensation (reference junction CJC): internal cold junction compensation or external cold junction, Field device [2]: Thermocouple, Field device [4]: mV source, Compensation (reference junction CJC): internal cold junction compensation or external cold junction
1-channel, Input Ex ia, Installation in suitable enclosures in Zone 1, Module can be exchanged under voltage (hot swap), Explosion protection: Ex ia, Function: Counter , Function [2]: frequency, Function [3]: direction of rotation, Connection: NAMUR sensor, Connection [2]: volt-free contact
8-channel, Inputs with plug-in Ex e terminals, Installation in suitable enclosures in Zone 1, Module can be exchanged under voltage (hot swap), Explosion protection: Ex e connection, Connection: NAMUR sensor, Connection [2]: volt-free contact, Connection [3]: active binary signal 24 V DC
1-channel, 1 digital output, 2 digital inputs, Inputs and output Ex ia, Installation in suitable enclosures in Zone 1, Explosion protection: Ex ia, Field device: Solenoid Valve, Field device [2]: audible alarm, Field device [3]: visual alarm