Select Your Country

Go to global website

FJ7-N Inductive sensor

Key Benefits at a Glance

  • 7 mm flush
Approval
Product Compliance: United Kingdom – UKCA
Approval
Product Compliance: Europe – CE
Note

All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.

EN
  • CS
  • DE
  • EN
  • ES
  • FR
  • IT
  • PL
  • PT
  • SV

Technical data of FJ7-N

Switching functionNormally closed (NC)
Output typeNAMUR
Rated operating distancesn7 mm
Installationflush
Assured operating distancesa0 ... 5.67 mm
Reduction factor rAl 0.4
Reduction factor rCu 0.3
Reduction factor r304 0.85
Output type2-wire
Nominal voltageUo8.2 V (Ri approx. 1 kΩ)
Operating voltageUB5 ... 25 V
Switching frequencyf0 ... 200 Hz
HysteresisHtyp. %
Current consumption
Measuring plate not detected≥ 3 mA at nominal voltage
Measuring plate detected≤ 1 mA at nominal voltage
Switching state indicatorLED, yellow
MTTFd4080 a
Mission Time (TM)20 a
Diagnostic Coverage (DC)0 %
Standard conformity
NAMUREN 60947-5-6:2000
StandardsEN IEC 60947-5-2
IECEx approval
Equipment protection level GbIECEx PTB 11.0021X
Equipment protection level MbIECEx PTB 11.0021X
ATEX approval
Equipment protection level GbPTB 00 ATEX 2032 X
Equipment protection level Gc (ic)PF13CERT2895 X
CCC approval
Hazardous Location2020322315002304
NEPSI approval
NEPSI certificateGYJ16.1394X
CML approvalon request
ANZEx19.3001X
Ambient temperature-25 ... 100 °C (-13 ... 212 °F)
Cable, fixed installation-25 ... 80 °C (-13 ... 176 °F)
Connection typecable
Housing materialbrass, zinc plated
Sensing facePOM
Degree of protectionIP67
Cable
Wire end ferrulesyes
Cable diameter4.8 mm ± 0.2 mm
Bending radius> 10 x cable diameter
MaterialPUR
Colorblue
Number of cores2
Core cross section0.34 mm2
LengthL2 m
Dimensions
Height24 mm
Width50 mm
Length25 mm
Use in the hazardous areasee instruction manuals