AS-Interface power supply, data decoupling, 4 A
Segment coupler 1, power supply and gateway for PROFIBUS DP to PROFIBUS PA communication, Output: 24 ... 26 V/400 mA, Couples PROFIBUS PA devices transparently to PROFIBUS DP, High-power trunk for high device count and long cable lengths, Installation in Zone 2/Class I, Div. 2, Up to 1.5 MBit auto-adapting, Europe, USA, Canada
Fieldbus power supply, module for fieldbus power hub, Output: 28 ... 30 V/500 mA, High-power trunk for high device count and long cable lengths, With galvanic isolation, Installation in Zone 2/Class I, Div. 2, For FOUNDATION Fieldbus H1 and PROFIBUS PA, IECEx approval, International, Europe, USA, Canada, Device coupler location: non-explosion hazardous area, Zone 2 - high-power trunk, Zone 1 - high-power trunk, Division 2 - high-power trunk, Division 1 - high-power trunk
Fieldbus power supply, module for fieldbus power hub, Output: 21 ... 23 V/500 mA, Voltage limitation for Entity ic and Ex nL, With galvanic isolation, Installation in Zone 2/Class I, Div. 2, For FOUNDATION Fieldbus H1 and PROFIBUS PA, IECEx approval, International, Europe, USA, Canada, Device coupler location: Zone 2 - high-power trunk, Instrument location / spur protection: Zone 2 - all relevant types of protection, Function: Fieldbus Power Supply
Fieldbus Power Supply, Output: 25 ... 27 V/360 mA, For most fieldbus applications, High-power trunk for high device count and long cable lengths, Installation in Zone 2/Class I, Div. 2, For FOUNDATION Fieldbus H1, Europe, USA, Canada, Device coupler location: non-explosion hazardous area, Zone 2 - high-power trunk, Zone 1 - high-power trunk, Division 2 - high-power trunk, Division 1 - high-power trunk, Device coupler location [2]: Zone 2 - high-power trunk
Power supply, 24 to 30 V DC, 10 A
Entrada de rango amplio de 100 V CA a 240 V CA, monofásica, Salida 24 V CC, 10 A, 240 W, Ancho de la carcasa: 39 mm, Dispositivo Mosfet de desacoplamiento integrado para redundancia 1+1 y N+1, Eficiencia de hasta el 94,7 %, Pico de sobrecorriente mínimo, Contacto de relé de CC correcto, Corriente compartida para uso en paralelo, Apto para montaje en Zona 2/Div. 2, Tipo de dispositivo: aparato para montaje en rail DIN, Función: redundancia, Tensión de medición: 24 V CC
Entrada de rango amplio de 100 V CA a 240 V CA, monofásica, Salida, 24 V CC, 20 A, 480 W, Ancho de la carcasa: 48 mm, Eficiencia de hasta el 95,6 %, Pico de sobrecorriente mínimo, Contacto de relé de CC correcto, Corriente compartida para uso en paralelo, Apto para montaje en Zona 2/Div. 2, Tipo de dispositivo: aparato para montaje en rail DIN, Función: Estándar, Tensión de medición: 24 V CC, Rango de tensión: 24 ... 28 V CC , Ajuste de fábrica: 24,1 V
Entrada de rango amplio de 100 V CA a 240 V CA, monofásica, Salida, 24 V CC, 20 A, 480 W, Ancho de la carcasa: 48 mm, Dispositivo Mosfet de desacoplamiento integrado para redundancia 1+1 y N+1, Eficiencia de hasta el 95,2 %, Pico de sobrecorriente mínimo, Contacto de relé de CC correcto, Corriente compartida para uso en paralelo, Apto para montaje en Zona 2/Div. 2, Tipo de dispositivo: aparato para montaje en rail DIN, Función: redundancia, Tensión de medición: 24 V CC
Entrada de 24 V CC a 28 V CC, 2 entradas con 1 salida, Salida 24 V CC, 20 A, Ancho de la carcasa: 32 mm, Dispositivos Mosfet de desacoplamiento integrados para redundancia 1+1 y N+1, Reparto de carga automática, Protección contra polaridad de entrada inversa, Cableado sencillo: terminal de distribución para polo negativo incluido, Indicador de estado de redundancia, Apto para montaje en Zona 2/Div. 2, Tipo de dispositivo: aparato para montaje en rail DIN, Función: Módulo de redundancia
AS-Interface power supply, data decoupling, 8 A
AS-Interface power supply, data decoupling, 2.8 A
Gateway module for fieldbus power hub for PROFIBUS PA to PRFIBUS DP Master communication, PROFIBUS DP V1 / For 4 segments PA, Couples PROFIBUS PA devices transparently to PROFIBUS DP, Optional redundant configuration, Installation in Zone 2/Class I, Div. 2, Up to 12 Mbit/s, auto adapting, IECEx approval, International, Europe, USA, Canada
Fieldbus power supply, module for fieldbus power hub, Output: 15 ... 17 V/500 mA, Voltage limitation for FISCO ic, Entity ic, also FNICO and Ex nL, With galvanic isolation, Installation in Zone 2/Class I, Div. 2, For FOUNDATION Fieldbus H1 and PROFIBUS PA, IECEx approval, International, Europe, USA, Canada, Device coupler location: Zone 2 - high-power trunk, Instrument location / spur protection: Zone 2 - all relevant types of protection, Function: Fieldbus Power Supply
Fieldbus power supply, module for fieldbus power hub, 2 segments, simplex, individual modules per segment, Couples PROFIBUS PA devices transparently to PROFIBUS DP, High-power trunk: Live work on devices in any hazardous area, Transparent, configuration free, Optimized for size and quality, low heat dissipation, IECEx approval, International, Europe, USA, Canada
Fieldbus power supply with low voltage for compact plants also in island mode, Output: 12 ... 13 V/220 mA, For battery or solar-powered applications, For demanding environmental conditions , Installation in Zone 2/Class I, Div. 2, For FOUNDATION Fieldbus H1, Europe, USA, Canada, Device coupler location: non-explosion hazardous area, Zone 2 - high-power trunk, Division 2 - high-power trunk, Device coupler location [2]: Zone 2 - high-power trunk
Power hub motherboard for Yokogawa ALF111, 4 segments, redundant, individual modules per segment, Customized for Yokogawa, ALF 111, High-power trunk: Live work on devices in any hazardous area, Best quality, smallest size and lowest heat dissipation, For FOUNDATION Fieldbus H1, IECEx approval, International, Europe, USA, Canada, Device coupler location: non-explosion hazardous area, Zone 2 - high-power trunk, Zone 1 - high-power trunk, Division 2 - high-power trunk, Division 1 - high-power trunk
Entradas de rango amplio de 380 V CA a 480 V CA, trifásica, Salida 24 V CC, 40 A, 960 W, Ancho de la carcasa: 110 mm, Eficiencia de hasta el 95,3 %, Pico de sobrecorriente mínimo, Interfaz IO-Link, Corriente compartida para uso en paralelo, Tipo de dispositivo: aparato para montaje en rail DIN, Función: IO-Link, Tensión de medición: 24 V CC, Rango de tensión: 24 ... 28,5 V CC limitación de hardware mediante potenciómetro , 15 ... 28 V CC mediante IO-Link , configuración de fábrica: 24,1 V
Power hub motherboard for Invensys FBM 228, 8 segments, redundant, individual modules per segment, Customized for Invensys, FBM228, High-power trunk: Live work on devices in any hazardous area, Best quality, smallest size and lowest heat dissipation, For FOUNDATION Fieldbus H1
Gateway module for fieldbus power hub for PROFINET to PROFIBUS PA communication, Gateway PROFINET RT to 4 x PROFIBUS PA segments, Up to 32 devices per PROFIBUS PA segment, Installation in Zone 2/Class I, Div. 2, Ring and system redundancy, Integrated webserver for diagnostics, IECEx approval, International, Europe, USA, Canada, Device coupler location: non-explosion hazardous area, Zone 2 - high-power trunk, Zone 1 - high-power trunk, Division 2 - high-power trunk, Division 1 - high-power trunk
Segment Coupler 1, intrinsically safe power supply and gateway for coupling PROFIBUS PA devices to PROFIBUS DP, Output: 12.6 ... 13.4 V/100 mA, Couples PROFIBUS PA devices transparently to PROFIBUS DP, Intrinsically safe, Ex ia (FISCO or Entity), Installation in Zone 2/Class I, Div. 2, Fixed, high-availability terminator, IECEx approval, Dust protection, Europe, USA, Canada, Device coupler location: Zone 2 - high-power trunk, Zone 1 - intrinsically safe trunk
Power hub motherboard for Yokogawa ALF111, 4 segments, individual modules per segment, Customized for Yokogawa, ALF 111, High-power trunk: Live work on devices in any hazardous area, Best quality, smallest size and lowest heat dissipation, For FOUNDATION Fieldbus H1, IECEx approval, International, Europe, USA, Canada, Device coupler location: non-explosion hazardous area, Zone 2 - high-power trunk, Zone 1 - high-power trunk, Division 2 - high-power trunk, Division 1 - high-power trunk
Fieldbus power hub, compact motherboard for Yokogawa ALF111 with redundant host terminals on the right, 4 segments, redundant, individual modules per segment, Customized for Yokogawa, ALF 111, High-power trunk: Live work on devices in any hazardous area, Best quality, smallest size and lowest heat dissipation, For FOUNDATION Fieldbus H1, IECEx approval, International, Europe, USA, Canada
Power hub motherboard for Yokogawa ALF111, 8 segments, redundant, individual modules per segment, Customized for Yokogawa, ALF 111, High-power trunk: Live work on devices in any hazardous area, Best quality, smallest size and lowest heat dissipation, For FOUNDATION Fieldbus H1, IECEx approval, International, Europe, USA, Canada, Device coupler location: non-explosion hazardous area, Zone 2 - high-power trunk, Zone 1 - high-power trunk, Division 2 - high-power trunk, Division 1 - high-power trunk
Fieldbus power hub, compact motherboard for Yokogawa ALF111 with redundant host terminals, 8 segments, redundant, individual modules per segment, Customized for Yokogawa, ALF 111, High-power trunk: Live work on devices in any hazardous area, Best quality, smallest size and lowest heat dissipation, For FOUNDATION Fieldbus H1, IECEx approval, International, Europe, USA, Canada
Entrada de rango amplio de 100 V CA a 240 V CA, monofásica, Salida, 12 V CC, 16 A, 192 W, Ancho de la carcasa: 39 mm, Eficiencia de hasta el 94,3 %, Pico de sobrecorriente mínimo, Control remoto para ENCENDIDO/APAGADO, Contacto de relé de CC correcto, Apto para montaje en Zona 2/Div. 2, Tipo de dispositivo: aparato para montaje en rail DIN, Función: Estándar, Tensión de medición: 12 V CC, Rango de tensión: 12 ... 15 V CC , Ajuste de fábrica: 12 V
Entrada de rango amplio de 100 V CA a 240 V CA, monofásica, Salida, 48 V CC, 5,4 A, 260 W, Ancho de la carcasa: 39 mm, Eficiencia de hasta el 95,5 %, Pico de sobrecorriente mínimo, Contacto de relé de CC correcto, Apto para montaje en Zona 2/Div. 2, Tipo de dispositivo: aparato para montaje en rail DIN, Función: Estándar, Tensión de medición: 48 V CC, Rango de tensión: 48 ... 56 V CC , Ajuste de fábrica: 48 V
Entradas de rango amplio de 380 V CA a 480 V CA, trifásica, Salida 24 V CC, 40 A, 960 W, Ancho de la carcasa: 110 mm, Eficiencia de hasta el 95,3 %, Pico de sobrecorriente mínimo, Entrada apagada, Control remoto para ENCENDIDO/APAGADO, Contacto de relé de CC correcto, Corriente compartida para uso en paralelo, Tipo de dispositivo: aparato para montaje en rail DIN, Función: Estándar, Tensión de medición: 24 V CC, Rango de tensión: 24 ... 28 V CC , Ajuste de fábrica: 24,1 V
Entrada de 24 V CC, Salida con aislamiento, 24 V CC, 10 A, 240 W, Ancho de la carcasa: 42 mm, Eficiencia de hasta el 94,2 %, Pico de sobrecorriente mínimo, Protección contra polaridad de entrada inversa, 20 % de reservas de potencia de salida, Tipo de dispositivo: aparato para montaje en rail DIN, Función: Estándar, Rango de tensión: 24 ... 28 V CC , Ajuste de fábrica: 24,1 V
Entrada de 12 V CC a 28 V CC, 2 entradas con 1 salida, Salida 24 V CC, 40 A, Ancho de la carcasa: 36 mm, Dispositivos Mosfet de desacoplamiento integrados para redundancia 1+1 y N+1, Solo caída de tensión de 72 mV con una corriente de salida de 20 A, Solo 1,7 W de pérdida con 2 x 10 A y 5,9 W con corriente de entrada 2 x 20 A, Protección contra polaridad de entrada inversa, Apto para montaje en Zona 2/Div. 2, Tipo de dispositivo: aparato para montaje en rail DIN, Función: Módulo de redundancia
AS-Interface power supply, data decoupling, 4 A, 24 V DC input voltage
Power hub motherboard for protocol gateways modules, For 2 gateway modules, For PROFIBUS PA, Redundant configuration, Installation in Zone 2/Class I, Div. 2, Spring terminals or screw terminals selectable, IECEx approval, International, Europe, USA, Canada, Device coupler location: non-explosion hazardous area, Zone 2 - high-power trunk, Zone 1 - high-power trunk, Division 2 - high-power trunk, Division 1 - high-power trunk, Device coupler location [2]: Zone 2 - high-power trunk
Power hub motherboard with common host interface, 4 segments, individual modules per segment, Supports all PLC and PCS hosts, High-power trunk: Live work on devices in any hazardous area, Best quality, smallest size and lowest heat dissipation, For FOUNDATION Fieldbus H1, IECEx approval, International, Europe, USA, Canada, Device coupler location: non-explosion hazardous area, Zone 2 - high-power trunk, Zone 1 - high-power trunk, Division 2 - high-power trunk, Division 1 - high-power trunk
Power hub motherboard for gateway and power supply modules, 4 segments, simplex, individual modules per segment, For PROFIBUS PA, For gateway and power supply modules, High-power trunk: Live work on devices in any hazardous area, Optional advanced diagnostics, IECEx approval, International, Europe, USA, Canada, Device coupler location: non-explosion hazardous area, Zone 2 - high-power trunk, Zone 1 - high-power trunk, Division 2 - high-power trunk, Division 1 - high-power trunk
Power hub motherboard with host system connectors, 4 segments, individual modules per segment, Customizable cable connections to any PLC and PCS hosts, High-power trunk: Live work on devices in any hazardous area, Best quality, smallest size and lowest heat dissipation, For FOUNDATION Fieldbus and PROFIBUS PA, IECEx approval, International, Europe, USA, Canada
Power hub motherboard with common host interface, 4 segments, redundant, individual modules per segment, Supports all PLC and PCS hosts, High-power trunk: Live work on devices in any hazardous area, Best quality, smallest size and lowest heat dissipation, For FOUNDATION Fieldbus H1, IECEx approval, International, Europe, USA, Canada
Power hub motherboard with host system connectors, 4 segments, redundant, individual modules per segment, Customizable cable connections to any PLC and PCS hosts, High-power trunk: Live work on devices in any hazardous area, Best quality, smallest size and lowest heat dissipation, For FOUNDATION Fieldbus and PROFIBUS PA, IECEx approval, International, Europe, USA, Canada
Power hub motherboard with common host interface, 8 segments, redundant, individual modules per segment, Supports all PLC and PCS hosts, High-power trunk: Live work on devices in any hazardous area, Best quality, smallest size and lowest heat dissipation, For FOUNDATION Fieldbus H1, IECEx approval, International, Europe, USA, Canada
Power hub motherboard with host system connectors, 8 segments, redundant, individual modules per segment, Supports all PLC and PCS hosts, High-power trunk: Live work on devices in any hazardous area, Best quality, smallest size and lowest heat dissipation, For FOUNDATION Fieldbus H1, IECEx approval, International, Europe, USA, Canada
Power hub motherboard with redundant host terminals, 8 segments, redundant, individual modules per segment, Supports all PLC and PCS hosts, redundant terminals, High-power trunk: Live work on devices in any hazardous area, Best quality, smallest size and lowest heat dissipation, For FOUNDATION Fieldbus H1 and PROFIBUS PA, IECEx approval, International, Europe, USA, Canada
Entrada de rango amplio de 100 V CA a 240 V CA, monofásica, Salida 24 V CC, 10 A, 240 W, Ancho de la carcasa: 39 mm, Eficiencia de hasta el 95,2 %, Pico de sobrecorriente mínimo, Contacto de relé de CC correcto, Apto para montaje en Zona 2/Div. 2, Tipo de dispositivo: aparato para montaje en rail DIN, Función: Estándar, Tensión de medición: 24 V CC, Rango de tensión: 24 ... 28 V CC , Ajuste de fábrica: 24,1 V
Entrada de rango amplio de 100 V CA a 240 V CA, monofásica, Salida, 24 V CC, 5 A, 120 W, Ancho de la carcasa: 32 mm, Eficiencia de hasta el 94,3 %, Pico de sobrecorriente mínimo, Contacto de relé de CC correcto, Apto para montaje en Zona 2/Div. 2, Tipo de dispositivo: aparato para montaje en rail DIN, Función: Estándar, Tensión de medición: 24 V CC, Rango de tensión: 24 ... 28 V CC , Ajuste de fábrica: 24,1 V
49 / 52