Visite el sitio web global
Fieldbus diagnostic handheld for comprehensive diagnostics of the fieldbus physical layer, Comprehensive diagnostics for the fieldbus physical layer, Handheld with display and integrated expert system, Fieldbus interface Ex ia, FISCO, Entity, and DART, For commissioning, online monitoring and troubleshooting, For FOUNDATION Fieldbus H1 and PROFIBUS PA, IECEx approval, Dust protection, Europe
Fieldbus power supply, module for fieldbus power hub, Output: 28 ... 30 V/500 mA, High-power trunk for high device count and long cable lengths, With galvanic isolation, Installation in Zone 2/Class I, Div. 2, For FOUNDATION Fieldbus H1 and PROFIBUS PA, IECEx approval, International, Europe, USA, Canada, Device coupler location: non-explosion hazardous area, Zone 2 - high-power trunk, Zone 1 - high-power trunk, Division 2 - high-power trunk, Division 1 - high-power trunk
Advanced diagnostic module, plug-in module for the fieldbus power hub, Comprehensive diagnostics for fieldbus physical layer and power supply, Plug-in Module for the FieldConnex Power Hub, Precise measurements through passive circuits, For commissioning, online monitoring and troubleshooting, For FOUNDATION Fieldbus H1 and PROFIBUS PA, IECEx approval, International, Europe, USA, Canada
32 canales, Alimentación de 24 V CC, Entrada de dispositivo de campo HART (revisión 5 a 7), RS 485-Interface, Hasta SIL 3 según IEC/EN 61508
32 canales, Alimentación de 24 V CC, Interfaz para opciones de cableado en serie o paralelo, Conexiones RS 485 dobles, Espacio para multiplexador HART, Número de canales: 32 lazos de señal desequilibrada
IDENTControl Compact control interface with Ethernet interface for TCP/IP, PROFINET, EtherNet/IP, and MODBUS TCP protocols
IDENTControl Compact RFID evaluation unit with EtherCAT interface
IDENTControl RFID control interface with multiprotocol Ethernet interface
I/O hub with IO-Link interface for 16 digital inputs
Ethernet IO module with 16 configurable digital inputs/outputs
Ethernet IO-Link module with 8 inputs/outputs
Ethernet IO-Link module with eight IO-Link ports
HF RFID read/write device with IO-Link in accordance with ISO 15693
UHF RFID read/write device, USA, Canada and Mexico
Interfaz para carril de alimentación, Se utiliza para configuración redundante, Corriente de alimentación ≤ 4 A, Fusible reemplazable, Salida de contacto de relé, reversible, Indicación de estado LED
Barrera aislada de 1 canal, Alimentación de 24 V CC (carril de alimentación), Entrada de dispositivo de campo HART con fuente de alimentación del transmisor, Se puede utilizar como divisor de señal (1 entrada y varias salidas), 3 salidas analógicas 4 mA ... 20 mA, Salida de modo disipador y fuente, Configurable con el teclado, Anchura de la carcasa: 40 mm, Cantidad de canales: 1 canal, Comunicación HART, Relés de valores límite, Tensión de medición: 19 ... 30 V CC, Función: alimentación del transmisor
Acondicionador de señal de 1 canal, Alimentación de 24 V CC (carril de alimentación), Entrada para transmisores SMART de 2 hilos y 3 hilos y fuentes de corriente SMART de 2 hilos, Divisor de señal (1 entrada y 2 salidas), Salida doble de 4 mA ... 20 mA, disipador de corriente/fuente de corriente, Terminales con puntos de prueba, Hasta SIL 2 (SC 3) conforme a IEC/EN 61508, Anchura de la carcasa: 20 mm, Cantidad de canales: 1 canal, Comunicación HART, Conectores hembra de prueba
Acondicionador de señal de 1 canal, Alimentación de 24 V CC (carril de alimentación), Entrada de corriente o tensión aumentable, Salida de corriente o tensión, Salida de contacto de relé, Configurable con el teclado, Supervisión de fallos de conducción, Anchura de la carcasa: 20 mm, Cantidad de canales: 1 canal, Tensión de medición: 20 ... 30 V CC, Tipo: 1 x Relé (contacto de conmutación), Señal: 1 x 0/4 ... 20 mA, Señal [2]: 1 x 0/1 ... 5 V, Señal [3]: 1 x 0/2 ... 10 V
Fieldbus Power Supply, Output: 25 ... 27 V/360 mA, For most fieldbus applications, High-power trunk for high device count and long cable lengths, Installation in Zone 2/Class I, Div. 2, For FOUNDATION Fieldbus H1, Europe, USA, Canada, Device coupler location: non-explosion hazardous area, Zone 2 - high-power trunk, Zone 1 - high-power trunk, Division 2 - high-power trunk, Division 1 - high-power trunk, Device coupler location [2]: Zone 2 - high-power trunk
Sensor fotoeléctrico de detección directa, Diseño en miniatura con opciones de montaje versátiles, Rango de temperaturas ampliado, -40 °C a 60 °C., Alto grado de protección IP69K., Interface IO-Link para datos de servicio y proceso
Sensor fotoeléctrico de detección directa, Tamaño mediano con opciones de montaje versátiles, Rango de temperaturas ampliado, -40 °C a 60 °C., Alto grado de protección IP69K., Interface IO-Link para datos de servicio y proceso
Tamaño mediano con opciones de montaje versátiles, Interface IO-Link para datos de servicio y proceso, Varias frecuencias para evitar interferencias cruzadas, Rango de temperaturas ampliado, -40 °C a 60 °C., Alto grado de protección IP69K.
Sensor fotoelélectrico de barrera unidireccional láser, Tamaño mediano con opciones de montaje versátiles, Sensores láser DuraBeam: duraderos y utilizables como LED, Interface IO-Link para datos de servicio y proceso, Varias frecuencias para evitar interferencias cruzadas, Rango de temperaturas ampliado, -40 °C a 60 °C.
Sensor óptico de barrera por reflexión láser, Diseño en miniatura con opciones de montaje versátiles, Sensores láser DuraBeam: duraderos y utilizables como LED, Rango de temperaturas ampliado, -40 °C a 60 °C., Alto grado de protección IP69K., Interface IO-Link para datos de servicio y proceso
Sensor óptico de barrera por reflexión con filtro polarizado, Tamaño mediano con opciones de montaje versátiles, Rango de temperaturas ampliado, -40 °C a 60 °C., Alto grado de protección IP69K., Interface IO-Link para datos de servicio y proceso
Sensor óptico de barrera por reflexión láser, Tamaño mediano con opciones de montaje versátiles, Sensores láser DuraBeam: duraderos y utilizables como LED, Rango de temperaturas ampliado, -40 °C a 60 °C., Alto grado de protección IP69K., Interface IO-Link para datos de servicio y proceso
Sensor óptico de barrera por reflexión con filtro polarizado, Diseño en miniatura con opciones de montaje versátiles, Rango de temperaturas ampliado, -40 °C a 60 °C., Alto grado de protección IP69K., Interface IO-Link para datos de servicio y proceso
Sensor de triangulación con supresión de fondo, Diseño en miniatura con opciones de montaje versátiles, Sensores láser DuraBeam: duraderos y utilizables como LED, Rango de temperaturas ampliado, -40 °C a 60 °C., Alto grado de protección IP69K., Interface IO-Link para datos de servicio y proceso
Sensor fotoeléctrico láser de detección directa con supresión de fondo ajustable, Diseño en miniatura con opciones de montaje versátiles, Sensores láser DuraBeam: duraderos y utilizables como LED, Rango de temperaturas ampliado, -40 °C a 60 °C., Alto grado de protección IP69K., Interface IO-Link para datos de servicio y proceso
Sensor de triangulación con supresión de fondo, Diseño en miniatura con opciones de montaje versátiles, El mejor supresor de fondo de su clase, Detección precisa de objetos, casi independientemente del color, Rango de temperaturas ampliado, -40 °C a 60 °C., Alto grado de protección IP69K.
49 / 2731
¿Busca más información? Puede obtener más información en nuestras páginas relacionadas.
Lea las últimas noticias y aplicaciones sobre los productos seleccionados.