LHCS-51 Pressure Transmitter
Principaux avantages en un coup d'œil
- Device for hydrostatic pressure measurement in liquids or paste-like media
- Rope version
- Modular probe program to ensure optimum process adaptation
- Temperature range up to 85 °C (185 °F)
- Pressure range up to 10 bar (150 psi)
- Easy commissioning without the need for an operating tool
- Configurable by PACTware
Afficher plus



Remarque
Tous les documents relatifs aux produits, tels que les certificats, les déclarations de conformité, etc., qui ont été émis avant la conversion sous le nom de Pepperl+Fuchs GmbH ou Pepperl+Fuchs AG, s'appliquent également à Pepperl+Fuchs SE.
EN
- EN
- DE
Données techniques relatives à LHCS-51
| Construction type | device with rope probe | |
| Series | LHCS |
| Rated voltage | Ur | versions for safe area: 11.5 ... 35 V DC, HART, 2-wire 9 ... 32 V DC, PROFIBUS PA version for hazardous area see safety information (SI) |
| Measured variable | hydrostatic pressure , relative pressure | |
| Measuring range | 0.1 ... 10 bar max. turn down: 100:1 |
| Output signal | 4 ... 20 mA with superimposed digital communication protocol HART 6.0, 2-wire digital communication signal PROFIBUS PA (Profile 3.02) | |
| Communication | 4 ... 20 mA HART (standard) PROFIBUS PA (option) |
| Electromagnetic compatibility | |||||
| |||||
| Low voltage | |||||
| |||||
| Degree of protection | IEC 60529:2001 |
| Accuracy | reference accuracy: 0.2 % (standard), 0.1 % (platinum) The reference accuracy comprises the non-linearity according to limit point setting, hysteresis and non-reproducibility acc. to IEC 60770. The data refer to the calibrated span. | |
| Long-term drift | up to 0.05 % of upper range limit (URL)/year up to 0.125 % of upper range limit (URL)/5 years |
| Process conditions | |||||
| |||||
| Ambient temperature | PE cable: -40 ... 70 °C (-40 ... 158 °F) FEP cable: -40 ... 80 °C (-40 ... 176 °F) with display -20 ... 70 °C (-4 ... 158 °F) | |
| Storage temperature | PE cable: -40 ... 70 °C (-40 ... 158 °F) FEP cable: -40 ... 80 °C (-40 ... 176 °F) |
| Degree of protection | IP66, NEMA 4X IP68, NEMA 6P (24 hours in water 1.83 m (6 ft) deep) IP69K (with separate housing and FEP cable) | |
| Connection | gland M20 thread M20, G1/2, NPT1/2 device plug M12 HAN7D Harting connector, angled valve connector acc. ISO 4400, cable 5 m | |
| Material | process connections: AISI 316L (1.4435 or 1.4404), Alloy C276 (2.4819) housing: - die-cast aluminum with protective powder-coating on polyester base, housing F31 - stainless steel AISI 316L (1.4404), housing F15 rope: PE cable or FEP cable process isolating diaphragm: Alloy C276 (2.4819), Rhodium Gold Alloy C276, Platinum Gold Alloy C276 sealing measuring cell: welded measuring cell or FKM Viton, EPDM, Kalrez | |
| Process connection | threads ISO 228: G1-1/2, threads ANSI: NPT1/2 flanges EN 1092-1: DN 40 ... DN 100, flanges ANSI 16.5: 2 ... 4 in, flanges JIS B2220 |
| EU-type examination certificate | see instruction manuals (SI) | ||||
| Directive conformity | |||||
| |||||
| FM approval | see instruction manuals (SI) | |
| CSA approval | see instruction manuals (SI) | |
| IECEx approval | see instruction manuals (SI) |
| Drinking water approval | NSF61 approval | |
| Overspill protection | see approval (ZE) |
| Supplementary documentation | technical information (TI) manuals, brief instructions (BA, KA) instruction manuals (SI) control drawings (ZD) approval (ZE) | |
| Supplementary information | EC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com. |
| Designation | see technical information (TI) |
Pages associées
Vous cherchez plus d'informations ? N'hésitez pas à consulter nos pages associées pour en savoir plus.
Actualités et applications connexes
En savoir plus sur les actualités et les applications liées à ce produit.