Not available for purchase: 2-channel isolated barrier, 24 V DC supply (Power Rail), Input 2-wire SMART transmitters, Output 0/2 V ... 10 V, Terminals with test points, Up to SIL 2 acc. to IEC 61508, Housing width: 20 mm, Number of channels: 2-channel, HART communication, Test sockets, Safety Integrity Level (SIL): SIL 2, Rated voltage: 20 ... 35 V DC, Field device: 2-wire transmitter, Signal: 0/4 ... 20 mA, Signal: 2 x 0/2 ... 10 Vpa
Not available for purchase: 2-channel isolated barrier, 24 V DC supply (Power Rail), Input 2-wire SMART transmitters, Output 0/2 V ... 10 V, Terminals with test points, Up to SIL 2 acc. to IEC 61508, Housing width: 20 mm, Number of channels: 2-channel, HART communication, Rated voltage: 20 ... 35 V DCpa
Not available for purchase: 2-channel, Input EEx ia IIC; Uo = 25.2 V, Device installation in Zone 2, 24 V DC supply voltage, SMART capable up to 7.5 kHz (-3 dB), EMC acc. to NAMUR NE 21, Up to SIL 2 acc. to IEC 61508, Housing width: 20 mm, Number of channels: 2-channel, HART communication, Rated voltage: 20 ... 35 V DCpa
Not available for purchase: 2-channel isolated barrier, 24 V DC supply (Power Rail), Input 2-wire SMART transmitters, Output 0/2 V ... 10 V, Terminals with test points, Up to SIL 2 acc. to IEC/EN 61508, Housing width: 20 mm, Number of channels: 2-channel, HART communication, Test sockets, Safety Integrity Level (SIL): SIL 2, Rated voltage: 20 ... 35 V DC, Field device: 2-wire transmitter, Signal: 0/4 ... 20 mA, Signal: 2 x 0/2 ... 10 Vpa
From barcode scanners to 2-D code readers and handhelds to special solutions—get to know Pepperl+Fuchs' optical identification portfolio ... scanners to 2-D code readers and handhelds to special solutions Optical Identification The applications in the field of optical identification could not be more diverse. Whether particularly large reading and detection ranges, DPM codes, extreme ...
Pepperl+Fuchs is expanding its portfolio of universal isolated barriers with the HiC2422 intrinsic safety barrier ... barriers with the HiC2422 intrinsic safety barrier . The new module has two freely configurable channels for analog signals, which means it can be used both as a SMART transmitter power supply for two-wire transmitters and as a current driver for valve ...
With their flexibility and modularity, the VOS 2-D universal vision sensors offer the perfect solution for your vision application Learn more about the components and software of the VOS sensor series ... arm to grip the battery modules precisely. Automated Matching of Labels To ensure maximum transparency and quality control, the VOS 2-D universal vision sensor checks labels for complete printing. The camera automatically reads the content of a two ...
See Overview: Ethernet-APL levels Erhernet to Process Industry requirements ... in the field of process plants : Simple installation or familiar 2-wire installation Simple connection technology Polarity independence Flexible planning of the topology Support of Trunk-and-Spur technology FieldConnex components meet all the infrastructure ...
Fire protection on ships is a very current and important issue Intelligent safety relays guaranteereliable switching processes and additional diagnostic functions Learn more about the latest additio ... are force guided, this poses the additional risk of misinformation stating that a conductive connection has been established. The Benefits In addition to increased reliability, the safety relays in the KFD2-RSH series also provide a unique diagnostics ...
See Overview: Our Bebco EPS Ex pz purge system is designed to purge and pressurize the protected enclosure ... systems Built-in programming (programmable temperature control/ leakage compensation ) 7500 Series Ex pzc Purge System The 7500 series Ex pzc purge and pressurization system is a universally powered, globally certified system for Zone 2/22 and Division ...
See Overview: Our Bebco EPS Type Z purge system protects enclosures in Division 2 / Zone 2 hazardous areas ... The Pepperl+Fuchs Bebco EPS Type Z purge and pressurization systems provide easy selection, installation, and operation for enclosures located in Division 2 / Zone 2 hazardous areas . The Type Z solutions consist of a control unit, vent ...
See Overview: The PCV, PXV, and safePXV Data Matrix positioning systems from Pepperl+Fuchs use Data Matrix codes for precise positioning They consist of a 2-D camera system, a read head, and Data Matrix code tape Learn more about our positioning ... precision and incredibly reliable positioning . The self-adhesive code tape is attached to a fixed part of the system or plant, such as the wall of an elevator shaft or the mounting rail of an electric monorail system (EMS). The 2-D read head is mounted ...
See Overview: Pepperl+Fuchs handhelds offer a high degree of user-friendliness ... all common 1-D and 2-D codes. The compact handheld reader is parameterized easily using the control codes. Stationary use with a mounting bracket ensures maximum efficiency in the working processes. The automatic motion detection of the handheld reader ...
See Overview: The industrial event cameras from Pepperl+Fuchs can record short video sequences before and after a trigger event Get to know the portfolio ... See Overview: The industrial event cameras from Pepperl+Fuchs can record short video sequences before and after a trigger event. Get to know the portfolio … ...
1-10/422Items Per Page:
No results found?
Hint: Use wildcard character * before your search term, modify your search, check your search terms for misspellings, or contact us with your specific request.