Not available for purchase: Connects the Remote Process Interface to the control system/PLC/PC via ControlNet, Couples the internal CAN bus to the external ControlNet, Device installation in Zone 2, Master function for the internal CAN bus, External bus: ControlNet, External baud rate 5 MBd, Separate service connection independent of the PCS or PLC through RS 485 interface in addition to ControlNet connection, 24 V DC supply voltage, External bus is always media-redundant, Redundant gateway possiblepa
Not available for purchase: Connects the Remote Process Interface to the control system/PLC/PC via ControlNet, Couples the internal CAN bus to the external ControlNet, Device installation in Zone 2, For the connection of max. 16 RPI devices, Master function for the internal CAN bus, External bus: ControlNet, External baud rate 5 MBd, Separate service connection independent of the PCS or PLC through RS 485 interface in addition to ControlNet connection, 24 V DC nominal supply voltage, External bus is always media-redundantpa
See Overview: From barcode scanners and measuring instruments to RFID read heads—DeviceMaster® serial gateways enable easy integration of devices featuring a RS-232/422/485 serial interface to higher-level Ethernet and industrial Ethernet networks ... From barcode scanners and measuring instruments to RFID read heads—DeviceMaster® serial gateways enable easy integration of devices featuring a RS-232/422/485 serial interface to higher-level Ethernet and industrial Ethernet networks ...
See Overview: Pepperl+Fuchs offers optical data couplers and optical data transmission systems Our optical data couplers allow bi-directional communication for storage & retrieval systems, transfer c ... See Overview: Pepperl+Fuchs offers optical data couplers and optical data transmission systems. Our optical data couplers allow bi-directional communication for storage & retrieval systems, transfer c ...
See Overview: The WCS position encoding system from Pepperl+Fuchs includes interface modules with integrated RS-485 or SSI outputs ... Pepperl+Fuchs offers a wide range of interface modules for connecting WCS read heads to standard interfaces. All available interface modules are compatible with read heads with the special RS-485 interface , and up to four read heads can ...
For determining the position of AGVs, reliable reference points are needed A rugged and compact RFID system enables precise navigation ... The IQT1-FP-R4-V1 read/write head detects the tag within its sensing range with the highest level of reliability , even while driving. It can be used on its own or with an additional control interface, and can be directly connected via its RS-485 interface ...
In the field of electronics manufacturing, microscopes are used to check for faults on assembled printed circuit boards (PCBs) A SmartRunner Detector laser profile sensor monitors the space in front ... are in the same compact housing. This makes the device ideal for installation in particularly tight spaces . Object detection in the inspection area can be read out via the RS-485 interface as a 2-D image , which is made available for control and documentation ...
See Overview: The WCS absolute linear positioning system provides precise position feedback for a wide range of applications Pepperl+Fuchs provides different WCS read head versions Learn more and fi ... contamination. RS-485, SSI, CANopen, IO-Link, PROFINET, EtherCAT, Fail Safe over EtherCAT (FSoE), or EtherNet/IP interfaces can be used to transmit data to the controller. Safety Guaranteed safeWCS/PUS Read Heads The proven WCS is also available for safety ...
With the acquisition of the business of Comtrol Corporation, a US-based pioneer in industrial Ethernet communication and IO-Link gateways, Pepperl+Fuchs is completing its portfolio of future-oriented ... data exchange standard in our blog . Read more Serial Gateways (DeviceMaster®) DeviceMaster® serial to Ethernet gateways enable superior device networking capabilities to connect RS-232/422/485 serial devices like barcode scanners, weight scales ...
Serial gateways from Pepperl+Fuchs Comtrol are used for connection of proven serial devices to modern Ethernet networks Learn more about the retrofit solution that ensures long-time investment securi ... ®) . This enables modernization while ensuring long-term investment security . Reliable Connection to Ethernet-Based Systems Pepperl+Fuchs serial gateways combine the serial communication protocols RS-232, RS-422, and RS-485 in one gateway. This means that almost ...
Pepperl+Fuchs' PXV absolute positioning system sets new benchmarks for reliability, noise immunity, and handling Discover the most reliable positioning system on the market ... axes ensure optimum position of the reader across the entire measuring range. RS-485 , SSI , PROFINET , and EtherNet/IP interfaces are integrated in the sensor‘s housing. These interfaces, and parameterization via Data Matrix control codes, PC ...
The WCS is designed for applications with extreme ambient conditions or especially long distances ... -485, SSI, CANopen, PROFINET, EtherCAT, or EthernetIP. A wide range of interface modules are available for connection to other fieldbus interfaces. Rugged Design Due to its U-shaped design, the WCS is resistant to ambient light and can even read dirty ...
1-10/12Items Per Page:
No results found?
Hint: Use wildcard character * before your search term, modify your search, check your search terms for misspellings, or contact us with your specific request.