1-channel, Plugs directly in to field side of KF modules, Analog or digital signal inputs, Surge protection up to 10 kA, Protects leads 1, 2 and 3 of KF modules, Uninterruptable operation (auto reset), Up to SIL 3 acc. to IEC/EN 61508pa
Surge Protection Technology for Process Industry from Pepperl+Fuchs ... , processes and the environment. Power Surge—The No. 1 Underestimated Cause of Damage Overvoltages due to lightning strikes or switching operations are one of the most common causes of electronic damage . In process engineering plants such as refineries ...
See Overview: Pepperl+Fuchs' modular Remote I/O systems, LB, and FB, connect field signals in the hazardous and the safe areas ... without stopping the PROFINET controller. FB (Zone 1) FB remote I/O is certified for mounting in Zone 1 , placing the remote I/O system close to field devices, and it is installed in an enclosure. This modular signal conditioning system allows you to interface ...
See Overview: Backplanes are holding LB Remote I/O Modules, Com units and power supplies ... of single-width and dual-width remote I/O modules, giving users high flexibility when configuring individual remote I/O solutions . The power supply is located on the backplane’s right side, and fieldbus connection is established on the left side. Due ...
See Overview: Pepperl+Fuchs offers 24 VDC, 115 V AC and 230 VAC power supplies for our LB Zone 2 remote I/O systems ... mounted on the corresponding backplane. The power supply features galvanic isolation to mains power and can be operated in redundancy mode . Based on the number of I/O modules and power consumption, a third remote I/O power supply in standby operation ...
The USi-safety ultrasonic sensor system is breaking new ground for safety applications—whether in challenging, dusty environments or in outdoor areas Learn more about the USi-safety ultrasonic sensor ... the system with single-fault tolerance in accordance with EN ISO 13849-1. In addition to the connections for the ultrasonic sensor units and the safe, short-circuit, and crossed-circuit monitored OSSD outputs, there is an input for a temperature sensor ...
See Overview: Pepperl+Fuchs offers relay output modules for our LB Zone 2 remote I/O systems 2-, 4- and 8- channel modules for valves, solenoid valves, optical and audible alarms ... possible utilization of backplanes for module connection while enabling compact remote I/O solutions with large channel numbers. Galvanic isolation separates the modules’ outputs from bus and power. In addition, the relay outputs are hot-swappable, which ...
See Overview: Pepperl+Fuchs offers temperature input modules for our LB Zone 2 remote I/O systems 1- and 4-channel temperature input modules for Pt 100 resistance thermometers, slide wire sensors, thermocouples and mV signals ... of protection Ex i . These signal converters are rated for use in Zone 2, Class I/Div. 2 explosion-hazardous areas and allow connection of different resistance thermometers (2-, 3- and 4-wire Pt100 ... Pt1000), thermocouples, and mV signals. LB system remote I/O ...
Learn how purge and pressurization systems from the well-known Pepperl+Fuchs brand Bebco EPS® can provide the solution for various challenging process automation uses cases ... to be equipped with remote I/O systems as well as conventional operating equipment. They are made entirely of SS316L stainless steel, making them suitable for harsh offshore conditions. Label Printer Solution for Ex Zones One of the problems with printers ...
Wherever vibrations occur, condition monitoring and predictive maintenance play a crucial role in ensuring personnel and plant protection Discover the new vibration sensor series by Pepperl+Fuchs, me ... sensors are the smallest vibration sensors in the series, suited for less complex applications . They are certified up to SIL 1/PL c for use in safety applications. The sensors of the VIM6 series are designed for use in high-temperature areas , where ...
Pepperl+Fuchs' new PROFINET gateways open up the door for industry 40 applications in process automation ... or outputs can be configured and assigned to any controller on one LB or FB remote I/O station . Thus users can reduce instruments, piping, wiring and the number of control cabinets significantly. Different Information—One Connection The PROFINET gateway ...
1-10/414Items Per Page:
No results found?
Hint: Use wildcard character * before your search term, modify your search, check your search terms for misspellings, or contact us with your specific request.