Not available for purchase: Sensing range up to 10 m, Self-monitoring (type 4 according to IEC/EN 61496-1), 2-radial design, Beam spacing 500 mm, Red transmission light, Integrated function display, Operating reserve indication, Operation on control units of SB4 (SafeBox), Performance level (PL): PL e, Connection: M16 cable gland , terminal compartmentfa
Not available for purchase: Sensing range up to 10 m, Self-monitoring (type 4 according to IEC/EN 61496-1), 2-radial design, Beam spacing 500 mm, Red transmission light, Integrated function display, Operating reserve indication, Operation on control units of SB4 (SafeBox), Performance level (PL): PL e, Connection: M16 cable gland , terminal compartmentfa
Not available for purchase: Sensing range up to 10 m, 2-radial design, Beam spacing 500 mm, Self-monitoring (type 4 according to IEC/EN 61496-1), Red transmission light, Usable with or without start/restart disable, Integrated relay monitor, 7-segment diagnostic display, Operating mode: Start/restart disable, relay monitor,, Performance level (PL): PL e, Safety output: 2 separated fail safe semiconductor outputs, Connection: M16 cable gland , terminal compartment with cage-terminals, M12-connector for emitterfa
Not available for purchase: Sensing range up to 10 m, 2-radial design, Beam spacing 500 mm, Self-monitoring (type 4 according to IEC/EN 61496-1), Red transmission light, Usable with or without start/restart disable, Integrated relay monitor, 7-segment diagnostic display, Operating mode: Start/restart disable, relay monitor,, Performance level (PL): PL e, Safety output: 2 separated fail safe semiconductor outputsfa
Not available for purchase: Sensing range up to 10 m, 2-radial design, Beam spacing 500 mm, Self-monitoring (type 4 according to IEC/EN 61496-1), Red transmission light, Usable with or without start/restart disable, Integrated relay monitor, 7-segment diagnostic display, Operating mode: Start/restart disable, relay monitor,, Performance level (PL): PL e, Safety output: 2 relay outputs, force-guided NO-contactfa
Not available for purchase: Sensing range up to 10 m, 2-radial design, Beam spacing 500 mm, Self-monitoring (type 4 according to IEC/EN 61496-1), Red transmission light, Usable with or without start/restart disable, Integrated relay monitor, 7-segment diagnostic display, Operating mode: Start/restart disable, relay monitor,, Performance level (PL): PL e, Safety output: 2 relay outputs, force-guided NO-contact, Connection: M16 cable gland , terminal compartment with cage-terminals, M12-connector for emitterfa
Not available for purchase: Sensing range up to 10 m, 2-radial design, Beam spacing 500 mm, Self-monitoring (type 4 according to IEC/EN 61496-1), Red transmission light, Usable with or without start/restart disable, Sequential and parallel muting in various operating modes, Emergency muting for the correction of the material jam, Operating mode: Start/restart disable, relay monitor, muting operating modes, Performance level (PL): PL e, Safety output: 2 separated fail safe semiconductor outputsfa
Not available for purchase: Sensing range up to 10 m, 2-radial design, Beam spacing 500 mm, Self-monitoring (type 4 according to IEC/EN 61496-1), Red transmission light, Usable with or without start/restart disable, Sequential and parallel muting in various operating modes, Emergency muting for the correction of the material jam, Operating mode: Start/restart disable, relay monitor, muting operating modes, Performance level (PL): PL e, Safety output: 2 separated fail safe semiconductor outputsfa
Not available for purchase: Sensing range up to 10 m, 2-radial design, Beam spacing 500 mm, Self-monitoring (type 4 according to IEC/EN 61496-1), Red transmission light, Usable with or without start/restart disable, Sequential and parallel muting in various operating modes, Emergency muting for the correction of the material jam, Operating mode: Start/restart disable, relay monitor, muting operating modes, Performance level (PL): PL e, Safety output: 2 relay outputs, force-guided NO-contactfa
Not available for purchase: Sensing range up to 10 m, 2-radial design, Beam spacing 500 mm, Self-monitoring (type 4 according to IEC/EN 61496-1), Red transmission light, Usable with or without start/restart disable, Sequential and parallel muting in various operating modes, Emergency muting for the correction of the material jam, Operating mode: Start/restart disable, relay monitor, muting operating modes, Performance level (PL): PL e, Safety output: 2 relay outputs, force-guided NO-contactfa
From barcode scanners to 2-D code readers and handhelds to special solutions—get to know Pepperl+Fuchs' optical identification portfolio ... Optical Identification | Pepperl+Fuchs Optical Identification Benefits Stationary 2-D Code Readers Stationary Barcode Scanners 2-D Code Handheld Readers Special Solutions Contact Us Reliably Identified Mobile and stationary sensors—from barcode ...
Pepperl+Fuchs is expanding its portfolio of universal isolated barriers with the HiC2422 intrinsic safety barrier ... positioners. This dual functionality reduces inventory requirements and ensures cost savings for the end user. Two Functions, One Device Positioners ensure that the valve actuator is brought into a position specified by the control system. They are often ...
With their flexibility and modularity, the VOS 2-D universal vision sensors offer the perfect solution for your vision application Learn more about the components and software of the VOS sensor series ... arm to grip the battery modules precisely. Automated Matching of Labels To ensure maximum transparency and quality control, the VOS 2-D universal vision sensor checks labels for complete printing. The camera automatically reads the content of a two ...
See Overview: Ethernet-APL levels Erhernet to Process Industry requirements ... in the field of process plants : Simple installation or familiar 2-wire installation Simple connection technology Polarity independence Flexible planning of the topology Support of Trunk-and-Spur technology FieldConnex components meet all the infrastructure ...
Automatic doors in busses and trains require door edge protection to prevent the unintentional trapping of passengers Photoelectric sensors from Pepperl+Fuchs are used to solve this application ... and monitor the total door area in a fan-shaped pattern with 6 light beams each. The overlapping light fan ensures maximum reliability with the smallest beam distances. Two-part TOPSCAN Solution 2: Here, the infrared light grid “TOPSCAN” is being employed. Up ...
In deep-freeze warehouses that handle frozen food products, goods are transported on trays Withstanding ambient temperatures from -35 °C to +45 °C, the VB14N-T barcode scanner identifies barcodes that are attached to the tray Learn more abouit it ... effect on the readability of the codes themselves. For minimal error rates and short throughput times, difficult-to-read codes must always be reliably recognized, even at high speeds. The Solution VB14N-T barcode scanner is made for temperatures down ...
See Overview: Our Bebco EPS Ex pz purge system is designed to purge and pressurize the protected enclosure ... systems Built-in programming (programmable temperature control/ leakage compensation ) 7500 Series Ex pzc Purge System The 7500 series Ex pzc purge and pressurization system is a universally powered, globally certified system for Zone 2/22 and Division ...
See Overview: Our Bebco EPS Type Z purge system protects enclosures in Division 2 / Zone 2 hazardous areas ... The Pepperl+Fuchs Bebco EPS Type Z purge and pressurization systems provide easy selection, installation, and operation for enclosures located in Division 2 / Zone 2 hazardous areas . The Type Z solutions consist of a control unit, vent ...
See Overview: The PCV, PXV, and safePXV Data Matrix positioning systems from Pepperl+Fuchs use Data Matrix codes for precise positioning They consist of a 2-D camera system, a read head, and Data Matrix code tape Learn more about our positioning ... precision and incredibly reliable positioning . The self-adhesive code tape is attached to a fixed part of the system or plant, such as the wall of an elevator shaft or the mounting rail of an electric monorail system (EMS). The 2-D read head is mounted ...
See Overview: Pepperl+Fuchs handhelds offer a high degree of user-friendliness ... all common 1-D and 2-D codes. The compact handheld reader is parameterized easily using the control codes. Stationary use with a mounting bracket ensures maximum efficiency in the working processes. The automatic motion detection of the handheld reader ...
1-10/427Items Per Page:
No results found?
Hint: Use wildcard character * before your search term, modify your search, check your search terms for misspellings, or contact us with your specific request.