Convergent mode sensor, 100 mm adjustable detection range, red light, light/dark on, PNP output, M8 plug, Miniature design, Diffuse mode sensor with long, narrow light spot, Easy to use, Very bright, highly visible light spot, Full metal thread mountingfa
Convergent beam sensor, 100 mm adjustable detection range, blue light, light/dark on, NPN output, fixed cable, Miniature design, Diffuse mode sensor with long, narrow light spot, Easy to use, Very bright, highly visible light spot, Full metal thread mountingfa
Convergent beam sensor, 100 mm adjustable detection range, blue light, light/dark on, PNP output, fixed cable, Miniature design, Diffuse mode sensor with long, narrow light spot, Easy to use, Very bright, highly visible light spot, Full metal thread mountingfa
Convergent beam sensor, 100 mm adjustable detection range, blue light, light/dark on, NPN output, M8 plug, Miniature design, Diffuse mode sensor with long, narrow light spot, Easy to use, Very bright, highly visible light spot, Full metal thread mountingfa
Convergent beam sensor, 100 mm adjustable detection range, blue light, light/dark on, PNP output, M8 plug, Miniature design, Diffuse mode sensor with long, narrow light spot, Easy to use, Very bright, highly visible light spot, Full metal thread mountingfa
Convergent mode sensor, 100 mm adjustable detection range, red light, light/dark on, NPN output, fixed cable, Miniature design, Diffuse mode sensor with long, narrow light spot, Easy to use, Very bright, highly visible light spot, Full metal thread mountingfa
See Overview: Pepperl+Fuchs' IO-Link masters facilitate reliable communication between management and sensor/actuator levels ... facilitate reliable, efficient communication between management and sensor/actuator levels as they assume a gateway function between Ethernet and IO‑Link. Up to eight IO‑Link devices may be directly connected—four channels are available for sensors, four ...
See Overview: Safety through beam sensors from Pepperl+Fuchs form a modular protective system with an operating range of up to 65 meters ... The through-beam photoelectric sensors SLA series is part of a category 2 or 4 self-monitoring photoelectric safety devices per EN 954-1 and EN 61496. It must be used with the SLVA or SC4-8 safety amplifiers. Up to 8 through-beam sensors can ...
Pepperl+Fuchs' Y-splitters help to reliably transmit sensor signals to the mobile crane control panel ... of control. The goal Individual signals from the eight sensors monitoring the supports must be connected logically and transmitted to the crane’s control panel. Conventional wiring methods, such as connecting sensors in series and joining them in terminal ...
See Overview: Pepperl+Fuchs offers optical data couplers and optical data transmission systems Our optical data couplers allow bi-directional communication for storage & retrieval systems, transfer c ... between two stations takes place with infrared light, which is modulated by a data clock. Optical data couplers with many common interfaces used in industry are available. The data transfer takes place either serially or in 8-bit parallel mode. ...
Pepperl+Fuchs offers a comprehensive portfolio of industrial sensor technology for the automated production of PV wafers, PV cells and PV modules Learn more ... , solar wafers are difficult for photoelectric sensors to detect. The ML100 series diffuse mode sensors offer maximum precision for this demanding task: unlike conventional sensors, they work with BlueBeam technology instead of a red LED. For wafer ...
See Overview: FieldConnex Process Interfaces connect multiple conventional inputs & outputs to the fieldbus with minimum cabling Process Interfaces allow flexibility through standard function blocks ... The FieldConnex® Temperature Multi-Input Device(TM-I) integrates up to eight analog signals into digital fieldbus communication in a very efficient and cost-effective way. The following types of devices and signals can be connected: Resistive temperature sensors ...
See Overview: FieldConnex Process Interfaces connect many conventional inputs & outputs to the fieldbus with less cabling Process Interfaces for PROFIBUS PA allow flexibility through standard functio ... Temperature Multi-Input Device The FieldConnex® Temperature Multi-Input Device ( TM-I ) integrates up to eight analog signals into digital fieldbus communication in a very efficient and cost-effective way. The following types of devices and signals can ...
See Overview: DMT grounding systems are Ex d and Ex tb certified and designed to monitor the capacitance and resistance of equipment where static charges can occur ... fitted to 8 meters of cable. Therefore, the devices measure and monitor the continuity to earth in order to eliminate electrostatic charges while vehicles transfer combustible products. Contact your Pepperl+Fuchs representative to learn about your ...
Learn more about radar frequency bands and different types of radar systems ... range of up to two gigahertz (GHz). The C-band (4 to 8 GHz) is used for weather radar and monitoring the sea surface. Radio waves in the X-band (8 to 12 GHz) offer high resolution and can penetrate thin walls. They are therefore suitable for precision ...
See Overview: Pepperl+Fuchs offers a wide range of field connectors for industrial applications ... threading types (M8, M12, M9, M23, valve connector, RD24, 1/2″, 7/8″), our field connectors portfolio covers a variety of pole numbers, straight or angled versions, as well as pin or socket contacts. With this many options, you always get the field connector ...