E1-Type approval, Measuring range 0 ... 360°, Analog output 4 mA ... 20 mA, Evaluation limits can be taught-in, 2 programmable switch outputs, High shock resistance, Increased noise immunity 100 V/m
Inertial measurement unit for inclination, acceleration and rotation rate measurement in 3-axis each, Dynamic inclination measurement despite external acceleration, Adjustable ranges for compensation of external accelerations, disturbances, Adjustable thresholds for detection of measured value overruns, Measurement of inclination, acceleration and rotation rate in 3 axis each, CAN bus with SAE J1939 protocol
E1-Type approval, Measuring range 0 ... 360°, High shock resistance, Extended temperature range , -40 ... +85 °C, CANopen interface, Increased noise immunity 100 V/m
Analog output 4 mA ... 20 mA, Fixed evaluation limits , High shock resistance, Increased noise immunity 100 V/m, Measuring range -30° ... +30°
E1-Type approval, Measuring range 0 ... 360°, Analog output 0 V ... 5 V, Evaluation limits can be taught-in, 2 programmable switch outputs, High shock resistance, Increased noise immunity 100 V/m
E1-Type approval, Measuring range -15° ... +15°, Analog output 4 mA ... 20 mA, Fixed evaluation limits , High shock resistance, Increased noise immunity 100 V/m
1 axis acceleration sensor, E1-Type approval, Analog output 4 mA ... 20 mA, Fixed evaluation limits , High shock resistance, Teachable zero point, Measuring range -2 g ... +2 g, Increased noise immunity 100 V/m
2 axis acceleration sensor, E1-Type approval, Analog output 4 mA ... 20 mA, Fixed evaluation limits , High shock resistance, Teachable zero point, Measuring range -2 g ... +2 g, Increased noise immunity 100 V/m
Inertial measurement unit for inclination, acceleration and rotation rate measurement in 3-axis each, Dynamic inclination measurement despite external acceleration, Adjustable ranges for compensation of external accelerations, disturbances, Adjustable thresholds for detection of measured value overruns, Measurement of inclination, acceleration and rotation rate in 3 axis each, CAN bus with CANopen
E1-Type approval, Measuring range 0 ... 360°, High shock resistance, Extended temperature range , -40 ... +85 °C, CAN bus with SAE J1939 protocol
Explosion-proof housing, Installation in Zone 1 and Zone 21, E1-Type approval, Measuring range 0 ... 360°, Analog output 4 mA ... 20 mA, Evaluation limits can be taught-in, 2 programmable switch outputs, High shock resistance, Increased noise immunity 100 V/m
E1-Type approval, Measuring range -15° ... +15°, Analog output 0 ... 10 V, Fixed evaluation limits , High shock resistance, Increased noise immunity 100 V/m
E1-Type approval, High shock resistance, Extended temperature range , -40 ... +85 °C, CANopen interface, Measuring range -15° ... +15°, Increased noise immunity 100 V/m
E1-Type approval, High shock resistance, Extended temperature range , -40 ... +85 °C, Measuring range -60° ... +60°, CAN bus with SAE J1939 protocol