LCR20 Level Radar
Key Benefits at a Glance
- Device for level measurement in liquids
- Radar measuring device with Bluetooth® wireless technology and HART communication
- Measuring range up to 20 m in fluids
- Process temperature up to 80 °C (176 °F)
- Process pressure up to 3 bar (43 psi)
- Accuracy up to ± 2 mm
- Commissioning, operation and maintenance via P+F Level app
- Configurable by PACTware
Show more









Note
All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.
EN
- EN
- DE
Technical data of LCR20
| Measuring method | The device is a measuring system that functions according to the time-of-flight method. The distance from the reference point (process connection of the measuring device) to the product surface is measured. | |
| Construction type | compact device | |
| Series | LCR |
| Rated voltage | Ur | 10.5 ... 30 V DC |
| Current consumption | input current : max. 25 mA start-up current : max. 3.6 mA | |
| Power consumption | input power : max. 675 mW |
| Surge protection | integrated | |
| Start-up time | first stable measured value after 20 s at 24 V DC |
| Interface type | HART | |
| Specification | 7.0 | |
| Supported functions | Additional Transmitter Status | |
| Vendor ID | 0x005D | |
| Device ID | 0x5DD3 | |
| Coding | signal encoding, FSK ±0.5 mA over current signal | |
| Transfer rate | 1200 Bit/s | |
| Load | min. 250 Ω |
| Interface type | Bluetooth | |
| Detection range | max. 25 m | |
| Configuration | commissioning, operation and maintenance via P+F Level app - can be activated/deactivated - password encryption | |
| Communication | encrypted |
| Measured variable | distance between reference point and product surface | |
| Measuring range | - device with 40 mm (1.5 inch) antenna: max. 15 m (49 foot) - device with 80 mm (3 inch) antenna: max. 20 m (66 foot) | |
| Operating frequency | approx. 26 GHz , K-Band | |
| Transmitter radiated power | mean power density in the direction of the beam - at a distance of 1 m (3.3 foot): < 12 nW/cm2 - at a distance of 5 m (16 foot): < 0.4 nW/cm2 |
| Output signal | 4 ... 20 mA , measured value output and power supply | |
| Signal on alarm | current output: 22.5 mA (in accordance with NAMUR recommendation NE 43) operating tool via digital communication (HART) or P+F Level (app) - status signal (as per NAMUR Recommendation NE 107) - plain text display with remedial action |
| Electromagnetic compatibility | |||||
| |||||
| Low voltage | |||||
| |||||
| Electromagnetic compatibility | NE 21 | |
| Degree of protection | IEC 60529:2001 | |
| Vibration resistance | DIN EN 60068-2-64 / IEC 60068-2-64 | |
| Climate class | DIN EN 60068-2-38/IEC 68-2-38 | |
| Bluetooth | IEEE 802.15.1 |
| Accuracy | up to ± 2 mm |
| Process conditions | ||||||||||||||
| ||||||||||||||
| Ambient temperature | -40 ... 80 °C (-40 ... 176 °F) -40 ... 60 °C (-40 ... 140 °F) when using the Bluetooth connection | |
| Storage temperature | -40 ... 80 °C (-40 ... 176 °F) | |
| Vibration resistance | 20 ... 2000 Hz, 1 (m/s2)2/Hz |
| Degree of protection | IP68, NEMA 6P (24 hours in water 1.83 m (6 ft) deep) IP66, NEMA 4X | ||||
| Connection | cable 2 x 0,75 mm2 | ||||
| Material | sensor housing: PVDF seal: EPDM back side process connection: PVDF cable gland: PA conduit adapter: CuZn nickel-plated O-ring: EPDM counter nut: PA6.6 design ring: PBT-PC front side process connection: PVDF cable: PVC | ||||
| Cable | |||||
| |||||
| Mass | - device with 40 mm (1.5 inch) antenna with 5 m cable: 2.5 kg - device with 80 mm (3 inch) antenna with 5 m cable: 2.8 kg | ||||
| Dimensions | - device with 40 mm (1.5 inch) antenna: ∅75 x 140 mm - device with 80 mm (3 inch) antenna: ∅115 x 206 mm | ||||
| Process connection | Back side: thread ISO228 G1, ASME MNPT1 Front side: - thread ISO228 G1-1/2, ASME MNPT1-1/2 - thread ISO228 G2, ASME MNPT2 - UNI slip on flange 3 inch/DN80/80, 4 inch/DN100/100, 6 inch/DN150/150 | ||||
| EU-type examination certificate | see instruction manuals | ||||
| Directive conformity | |||||
| |||||
| CSA approval | see instruction manuals (SI) | |
| IECEx approval | see instruction manuals |
| Telecommunications | radio license FCC |
| Supplementary documentation | technical information (TI) manuals, brief instructions (BA, KA) instruction manuals | |
| Supplementary information | Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com. |
| Designation | see technical information (TI) |