Select Your Country
NCN3-F31K2M-N4-B13-S Inductive sensor
Key Benefits at a Glance
- Direct mounting on standard actuators
- ATEX and IECEx approval
- Usable up to SIL 2 acc. to IEC 61508
- Weatherproof housing for outdoor applications
- Rugged metal base
- Plug-in terminals
- Temperature range
-40 ... 100 °C (-40 ... 212 °F)
Show more




Note
All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.
EN
- CS
- DE
- EN
- ES
- FR
- IT
- PL
- PT
- SV
Technical data of NCN3-F31K2M-N4-B13-S
Switching function | 2 x normally closed (NC) | |
Output type | NAMUR | |
Rated operating distance | sn | 3 mm |
Installation | flush mountable | |
Assured operating distance | sa | 0 ... 2.4 mm For assured operating distance sar see Manual Functional Safety. |
Actual operating distance | sr | 2.7 ... 3.3 mm typ. |
Actuating element | Stainless steel 1.4305 / AISI 303 8.5 mm x 8.5 mm x 0.5 mm | |
Reduction factor rAl | 0.4 | |
Reduction factor rCu | 0.4 | |
Reduction factor r304 | 0.7 | |
Reduction factor rSt37 | 1 | |
Reduction factor rBrass | 0.5 | |
Output type | 2-wire |
Nominal voltage | Uo | 8.2 V (Ri approx. 1 kΩ) | ||||||
Switching frequency | f | 0 ... 3 kHz | ||||||
Hysteresis | H | typ. 5 % | ||||||
Reverse polarity protection | reverse polarity protected | |||||||
Short-circuit protection | yes | |||||||
Suitable for 2:1 technology | yes , Reverse polarity protection diode not required | |||||||
Current consumption | ||||||||
| ||||||||
Time delay before availability | tv | ≤ 1 ms |
Safety Integrity Level (SIL) | SIL 2 | |
MTTFd | 1730 a | |
Mission Time (TM) | 20 a | |
Diagnostic Coverage (DC) | 0 % |
Voltage | max. 32 V DC | |
Current | max. 240 mA | |
Short-circuit protection | no | |
Reverse polarity protection | yes, with reversed output LED is out of function, therfore more power for solenoid valve |
Standard conformity | |||||||||||
|
IECEx approval | |||||||||||||||||
| |||||||||||||||||
ATEX approval | |||||||||||||||||
| |||||||||||||||||
UL approval | cULus Listed, General Purpose, Class 2 Power Source | ||||||||||||||||
| |||||||||||||||||
CCC approval | |||||||||||||||||
| |||||||||||||||||
KCC approval | |||||||||||||||||
|
Ambient temperature | -40 ... 100 °C (-40 ... 212 °F) | |
Storage temperature | -40 ... 100 °C (-40 ... 212 °F) |
Connection type | screw terminals | ||||||||||
Connection (system side) | Screw terminals, tightening torque min. 0.5 Nm Stripped length 7 mm , M20 x 1.5 cable gland , usable thread length 13.5 mm , screw-in depth max. 13.5 mm | ||||||||||
Core cross section (system side) | rigid: 0.14 ... 2.5 mm2 flexible: 0.14 ... 1.5 mm2 flexible with core-end sleeve: 0.25 ... 1.5 mm2 | ||||||||||
Connection (valve side) | like connection (system side) | ||||||||||
Core cross section (valve side) | like core cross section (system side) | ||||||||||
Housing material | PC (glass-fiber-reinforced Makrolon) | ||||||||||
Housing base | powder coated aluminum | ||||||||||
Degree of protection | IP66 / IP68 / IP69 | ||||||||||
Tightening torque, fastening screws | ≤ 5 Nm | ||||||||||
Tightening torque, housing screws | 1.5 Nm | ||||||||||
Tightening torque, earthing screw | 1.5 Nm | ||||||||||
Tightening torque, cable gland | M20 x 1.5 ; max. 11 Nm | ||||||||||
Tightening torque, stopping plug | 2 Nm | ||||||||||
Dimensions | |||||||||||
|
Use in the hazardous area | see instruction manuals |