Seleccione su país
EPV-6100-MP-* Enclosure Protection Vent
Enclosure protection vent for 6100 series purge and pressurization system
Ventajas clave de un vistazo
- Maximum flow rate of 14,000 l/min
- Intrinsically safe when connected to 6100 control unit






Nota
Todos los documentos relacionados con los productos, como certificados, declaraciones de conformidad, etc., que se emitieron antes de la conversión con el nombre de Pepperl+Fuchs GmbH o Pepperl+Fuchs AG también se aplican a Pepperl+Fuchs SE.
EN
- EN
- DE
- PT
Datos técnicos de EPV-6100-MP-*
| Series | 6100 Series | |
| System | Ex pxb Purge | |
| Hazardous environment | gas |
| Connection | |||||||||||
| |||||||||||
| Protective gas supply | Clean air or inert gas | |
| Safe pressure | 0.625 mbar [0.25 in wc / 6.4 mm wc) | |
| Enclosure pressure | 0 ... 50 mbar (0 ... 20.1 in wc / 0 ... 510.5 mm wc) | |
| Flow rate for leakage compensation | depends on enclosure seal based on completely sealed enclosure | |
| Breaking pressure | Approx. 10 mbar (4.0 in wc) Approx. 25 mbar (10.0 in wc) Approx. 30 mbar (12.1 in wc) Approx. 40 mbar (16.1 in wc) Approx. 50 mbar (20.1 in wc) |
| Electromagnetic compatibility | |||||
| |||||
| RoHS | |||||
| |||||
| Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) | |
| Storage temperature | -20 ... 80 °C (-4 ... 176 °F) | |
| Relative humidity | 5 ... 95 %, non-condensing | |
| Vibration resistance | 1 g , 3 ... 150 Hz , all axes | |
| Impact resistance | 30g, 11 ms, all axes |
| Material | 316L stainless steel (housing) | |
| Installation | -gravity dependent -air outlet, screen side must be facing down | |
| Mass | 17 kg (37 lb) |
| Certificate | CML 19 ATEX 1425X | ||||
| |||||
| Directive conformity | |||||
| |||||
| IECEx approval | IECEx CML 19.0156X Ex db eb ib [ib Gb][pxb Gb] IIC T4 Gb |
| Supplementary information | EC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com. Supplemental Standards : EN 61010-1:2010 |
Páginas relacionadas