Serviceline
Serviceline Industrial Sensors
Serviceline Explosion Protection

Signal Converters

Choose your product

Next PageLast Page
Product

Single-channel terminal amplifier with line breakage detection, input for NAMUR sensors, DC 24 V supply voltage, standardized interface to prevent signal transmission errors, switching state display, LED yellowfa

Relay output with 1 pole, yellow LED indicates switching state, Free-wheeling diode, Compact terminal housing, Clips onto standard 35 mm rail to DIN EN 50 022, Degree of protection IP20fa

Limit frequency 40 kHz, Voltage or current ouptput, Incrementing output
(Spacing factor 1 ... 9999), Multi-range power pack, 2-, 3-, 4-wire and NAMUR sensors as well as rotary encoder connectable, Rated voltage: 200 ... 230 V AC ; 100 … 130 V AC; 50 Hz
20 VDC ... 30 VDCfa
1-channel terminal amplifier, NAMUR sensor input, DC 24 V supply voltage, Standard interface for prevention of signal transmission errors, Switching status indicator, yellow LEDfa
1-channel terminal amplifier, NAMUR sensor input, DC 24 V supply voltage, Standard interface for prevention of signal transmission errors, Switching status indicator, yellow LEDfa
1-channel terminal amplifier, NAMUR sensor input, DC 24 V supply voltage, Standard interface for prevention of signal transmission errors, Switching status indicator, yellow LEDfa
Suitable for the connection of sensors and absolute encoders with SSI interface, Converts both SSI data and serial data into a parallel format, Parallel output 25 bit (Push-pull, short-circuit proof), RS 232 Interface for the serial read out of sensor information, SSI:Master or slave operation fa
Suitable for the connection of sensors and absolute encoders with SSI interface, Analog output 0/4 mA ... 20 mA, RS 232/RS 485-Interface for serial readout of sensor information, SSI:Master or slave operation , Specified option for arbitrary linearization characteristicsfa
1-channel signal conditioner, Universal usage at different power supplies, Input for 2- or 3-wire sensors, NAMUR sensors or dry contacts, Input frequency 1 mHz ... 10 kHz, Current output 0/4 mA ... 20 mA, Relay contact and transistor output, Start-up override, Line fault detection (LFD), Up to SIL 2 acc. to IEC 61508/IEC 61511pa
2-channel signal conditioner, Universal usage at different power supplies, Dry contact or NAMUR inputs, Input frequency 1 mHz ... 1 kHz, Current output 0/4 mA ... 20 mA, Relay contact and transistor output, Start-up override, Configurable by PACTware or keypad, Line fault detection (LFD), Rated voltage: 20 ... 90 V DC / 48 ... 253 V AC 50 ... 60 Hzpa
Next PageLast Page

Filter By