Serviceline Industrial Sensors
Serviceline Explosion Protection

Mounting aid DGE Montageplatte FLT

Montageplatte FLT
  • Mounting plate for the installation of FLT-8 series sensors in suspended ceilings
  • Front panel specially toughened and crack resistant
  • Carrying frame for sensor with adjustable 4-point fixture
  • Precise sensor orientation using additional adjustment screws

Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.

데이타 시트 발췌: 기술 사양  Montageplatte FLT

제품 설명
Mounting plate for FLT-8 series sensors
Mechanical specifications
MaterialPlastic ABS
Optical faceClear Plexiglas
Massapprox. 155 g
Dimensions
Width86 mm
Length205 mm
Suitable series
SeriesFLT-8

Classifications

SystemClasscode
ECLASS 13.027273701
ECLASS 12.027273701
ECLASS 11.027273701
ECLASS 10.0.127273701
ECLASS 9.027273701
ECLASS 8.027279202
ECLASS 5.127279202
ETIM 9.0EC003015
ETIM 8.0EC003015
ETIM 7.0EC003015
ETIM 6.0EC003015
ETIM 5.0EC003015
UNSPSC 12.131162301

Details: Montageplatte FLT

Datasheet: Montageplatte FLT

Datasheet파일 타입파일 크기
Datasheet Montageplatte FLTPDF153 KB
Datenblatt Montageplatte FLTPDF153 KB
Scheda tecnica Montageplatte FLTPDF154 KB
Hoja de datos Montageplatte FLTPDF157 KB

관련문서: Montageplatte FLT

Accessory of
Area scanner with long detection range for detecting people and objects, Version with Background evaluation, Reliable detection, including of difficult objects, through background evaluation, Possible detection range down to 0 m, Version with detection area 300 mm x 500 mm, Function: Outer area and cabin monitoring, Sensor principle: Area scanner, Operating voltage: 15 ... 48 V AC/DC, Signal output: Relay, 1 alternator, Connection: Connector, Binder series 581, 5-pinfa
Area scanner with long detection range for detecting people and objects, Version with Background evaluation, Reliable detection, including of difficult objects, through background evaluation, Possible detection range down to 0 m, Version with detection area 500 mm x 500 mm, Function: Outer area and cabin monitoring, Sensor principle: Counting sensor, Operating voltage: 15 ... 48 V AC/DC, Signal output: Relay, 1 alternator, Connection: Connector, Binder series 581, 5-pinfa
Area scanner with long detection range for detecting people and objects, Version with Background evaluation, Reliable detection, including of difficult objects, through background evaluation, Possible detection range down to 0 m, Version with detection area 50 mm x 500 mm, Function: Outer area and cabin monitoring, Sensor principle: Area scanner, Operating voltage: 15 ... 48 V AC/DC, Signal output: Relay, 1 alternator, Connection: Connector, Binder series 581, 5-pinfa
Area scanner with long detection range for detecting people and objects, Version with Background suppression, Ignores objects outside of selected area, Version with detection area 300 mm x 500 mm, Function: Outer area and cabin monitoring, Sensor principle: Area scanner, Operating voltage: 15 ... 48 V DC, Signal output: 2 PNP, complementary, short-circuit protected, open collectors, Connection: Connector, Binder series 581, 5-pinfa
Area scanner with long detection range for detecting people and objects, Version with Background suppression, Ignores objects outside of selected area, Version with detection area 300 mm x 500 mm, Light on version, Function: Outer area and cabin monitoring, Sensor principle: Area scanner, Operating voltage: 15 ... 48 V AC/DC, Signal output: Relay, 1 alternator, Connection: Connector, Binder series 581, 5-pinfa
Area scanner with long detection range for detecting people and objects, Version with Background suppression, Ignores objects outside of selected area, Version with detection area 500 mm x 500 mm, Function: Outer area and cabin monitoring, Sensor principle: Area scanner, Operating voltage: 15 ... 48 V DC, Signal output: 2 PNP, complementary, short-circuit protected, open collectors, Connection: Connector, Binder series 581, 5-pinfa
Area scanner with long detection range for detecting people and objects, Version with Background suppression, Ignores objects outside of selected area, Version with detection area 500 mm x 500 mm, Dark on version, Function: Outer area and cabin monitoring, Sensor principle: Area scanner, Operating voltage: 15 ... 48 V AC/DC, Signal output: Relay, 1 alternator, Connection: Connector, Binder series 581, 5-pinfa
Area scanner with long detection range for detecting people and objects, Version with Background suppression, Ignores objects outside of selected area, Version with detection area 50 mm x 500 mm, Function: Outer area and cabin monitoring, Sensor principle: Area scanner, Operating voltage: 15 ... 48 V DC, Signal output: 2 PNP, complementary, short-circuit protected, open collectors, Connection: Connector, Binder series 581, 5-pinfa
Area scanner with long detection range for detecting people and objects, Version with Background suppression, Ignores objects outside of selected area, Version with detection area 50 mm x 500 mm, Light on version, Function: Outer area and cabin monitoring, Sensor principle: Area scanner, Operating voltage: 15 ... 48 V AC/DC, Signal output: Relay, 1 alternator, Connection: Connector, Binder series 581, 5-pinfa