Línea de servicio de Sensores Industriales
+52 55 5636-0970
+52 55 5636-0975
Atención al cliente para protección contra explosiones
+52 55 5636-0970
+52 55 5636-0975

AS-Interface sensor/actuator module VAA-1E3A-M18-ZE/E2-V1

VAA-1E3A-M18-ZE/E2-V1
  • Input for 2-wire sensor
  • Function display for bus
  • For screw mounting in almost all metric threads and PGs
  • Unlimited addressing!
  • Power supply of the inputs and outputs from the external auxiliary voltage
  • Including M25 adapter to M18 x 1 for connection to MOVIMOT

Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.

Descargue la hoja de datos completa en PDF:


Extracto de la hoja de datos: Información técnica del  VAA-1E3A-M18-ZE/E2-V1

Descripción del producto
AS-Interface module in M18 stainless steel head ferrule
1 input/3 outputs
General specifications
Node typeStandard node
Functional safety related parameters
MTTFd350 a at 30 °C
Indicators/operating means
LED FAULTcommunication error / address is 0; LED red
LED PWRAS-Interface voltage; LED green
Electrical specifications
Auxiliary voltage (output)24 V DC ± 15 % PELV
(protection class 3 according to VDE 0106/IEC 364-4-41)
Rated operating voltage26.5 ... 31.6 V from AS-Interface
Rated operating current≤ 20 mA
Input
Number/Type1 Input for 2-wire sensor
Supplyfrom external auxiliary voltage UAUX
Switching pointOFF ≤ 0.8 mA
ON ≥ 5 mA
Output
Number/Type3 electronic outputs, PNP
Supplyfrom external auxiliary voltage UAUX
Current20 mA per output
Directive conformity
Electromagnetic compatibility
Directive 2014/30/EUEN 62026-2:2013
Standard conformity
Degree of protectionEN 60529:2000
AS-InterfaceEN 62026-2:2013
Programming instructions
ProfileS-9.F
IO code9
ID codeF
ID2 code0
Data bits (function via AS-Interface) input output
D0 - OUT1
D1 - OUT2
D2 - OUT3
D3 IN1 -
Parameter bits (programmable via AS-i)function
P0not used
P1not used
P2not used
P3not used
Ambient conditions
Ambient temperature0 ... 70 °C (32 ... 158 °F)
Storage temperature-40 ... 70 °C (-40 ... 158 °F)
Mechanical specifications
Degree of protectionIP67 according to EN 60529
The protection class appplies only for installation of the module in a connection housing for parts of the module located outside of the connection housing (external M12 connection, inside cable connection).
The housing duct must be sealed with a suitable adhesive.
ConnectionAS-Interface and auxiliary voltage: M12x1 round connector
auxiliary voltage, input and outputs: 20 cm connection cable
Mass110 g

Classifications

SystemClasscode
ECLASS 13.027242604
ECLASS 12.027242604
ECLASS 11.027242604
ECLASS 10.0.127242604
ECLASS 9.027242604
ECLASS 8.027242604
ECLASS 5.127242604
ETIM 9.0EC001599
ETIM 8.0EC001599
ETIM 7.0EC001599
ETIM 6.0EC001599
ETIM 5.0EC001599
UNSPSC 12.139121535

Details: VAA-1E3A-M18-ZE/E2-V1

Approvals: VAA-1E3A-M18-ZE/E2-V1

Seleccionar idioma:
Declaration of ConformityNúmero de CertificadoIdiomaTipo de archivoTamaño
EU Declaration of Conformity (P+F) / EU-Konformitäterklärung (P+F)DOC-2454CALLPDF109 KB
Descarga gratuita: Documento técnico sobre protocolos de comunicación basados en TCP (PDF)

Este documento técnico gratuito en formato PDF compara los diferentes protocolos de comunicación basados ​​en TCP (AMQP, OPC UA, MQTT, REST API) que se han abierto camino y se consideran los habilitadores de IIoT e Industria 4.0. Descárguelo ahora de forma gratuita.

Módulo de armario de conmutación AS-Interface KE5 – Manejo sencillo y manipulación mejorada

El diseño único de la carcasas del nuevo módulo de armario de conmutación KE5 permite una visibilidad superior y simplifica el montaje, cableado y mantenimiento dentro de los armarios de conmutación y cajas de conexiones.

Gama de productos AS-Interface