Utdrag ur datablad: Tekniska data för
TopScan-S-MS/L900
Product Description |
Single or multi-beam light curtain for individual protection according to DIN 18650/EN16005 |
General specifications |
Detection range min. | 0 ... 1500 mm |
Detection range max. | 0 ... 2500 mm |
Reference target | Minimum degree of reflection of the floor: 6 % Minimum degree of reflection to objects being detected: 0 % |
Light source | IRED |
Light type | modulated infrared light 875 nm |
Black-white difference (6 %/90 %) | < 2 % at 2000 mm sensor range |
Number of beams | 2 (number of built-in sensor modules AIR) |
Operating mode | Background evaluation |
Diameter of the light spot | 1.1 cm x 8.3 cm at 2000 mm sensor range |
Resolution | Reference object CA DIN 186850-1/EN 16005 in all applicable locations |
Functional safety related parameters |
Safety Integrity Level (SIL) | SIL 1 |
Performance level (PL) | PL c |
Category | Cat. 2 |
MTTFd | 880 a per module |
Mission Time (TM) | 20 a |
Diagnostic Coverage (DC) | 90 % |
Indicators/operating means |
Function indicator | LED red/green |
Control elements | Sensing range adjuster ; Adjuster for edge monitoring left/right |
Electrical specifications |
Operating voltage | 24 V DC +/- 20 % |
No-load supply current | 140 mA |
Input |
Test input | active at U = 11 V DC at 30 V DC inactive at U = -3 V DC at 5 V DC |
Output |
Switching type | Relay de-energized at object inside the scanning range |
Signal output | Relay, 1 alternator |
Switching voltage | 5 V ... 30 V AC/DC |
Switching current | max. 300 mA |
Response time | ≤ 70 ms |
Conformity |
Functional safety | ISO 13849-1 |
Product standard | EN 12978 ; EN 16005 ; DIN 18650 |
Approvals and certificates |
CCC approval | CCC approval / marking not required for products rated ≤36 V |
TÜV approval | TÜV NORD |
Ambient conditions |
Ambient temperature | -10 ... 50 °C (14 ... 122 °F) |
Relative humidity | Humidity at 20 °C: < 90 % Humidity at 60 °C: < 50 % |
Mechanical specifications |
Housing length L | 900 mm |
Mounting height | max. 2500 mm |
Degree of protection | IP52 , IP54 Optional (with special seal) |
Connection | screw terminals ; Cable cross-section 0.3 mm2 ... 1.3 mm2 (AWG26-16), single-stranded/multistranded CU |
Material | |
| Housing | aluminum / ABS |
| Optical face | PMMA |
Dimensions | |
| Height | 42 mm |
| Depth | 37 mm |
| Length | 900 mm |
Cable length | max. 30 m |
Note | Safety fuse ≤ 1 A (slow-blow) according to IEC 60127-2 Sheet 1 Recommendation: after a short circuit, check that the device is functioning correctly. |
Classifications
System | Classcode |
ECLASS 13.0 | 27270913 |
ECLASS 12.0 | 27270913 |
ECLASS 11.0 | 27270913 |
ECLASS 10.0.1 | 27270913 |
ECLASS 9.0 | 27270913 |
ECLASS 8.0 | 27270913 |
ECLASS 5.1 | 27270903 |
ETIM 9.0 | EC002550 |
ETIM 8.0 | EC002550 |
ETIM 7.0 | EC002550 |
ETIM 6.0 | EC002550 |
ETIM 5.0 | EC001821 |
UNSPSC 12.1 | 39121528 |
Details:
TopScan-S-MS/L900
Product Documentation:
TopScan-S-MS/L900
Design / Simulation:
TopScan-S-MS/L900
Approvals:
TopScan-S-MS/L900
Associated Products:
TopScan-S-MS/L900
Accessories |
|
|
|
Weather protection cover for sensing strips, Protection from adverse effects of weather such as rain, snow, etc., Can be cut to the required lengths, Retrofitting possible with already installed sensing stripsfa |
|
|
|
|
Sensor module for configurable TopScan-S, Master module, Category 2, tested and certified to DIN 18650/EN 16005, Safe function even on difficult floors, Easy adjustment of transmitter for hinge side/ opposite hinge side, Function: Open and secure, Sensor principle: Active infrared scanner, Operating voltage: 24 V DC +/- 20 %, Signal output: Relay, 1 alternatorfa |
|
|
|
|
Sensor module for configurable TopScan-S, Slave module, Category 2, tested and certified to DIN 18650/EN 16005, Safe function even on difficult floors, Easy adjustment of transmitter for hinge side/ opposite hinge side, Function: Open and secure, Sensor principle: Active infrared scanner, Operating voltage: 24 V DC +/- 20 %fa |
|
|
|
|
Aluminum profile for TopScan-S Series, Length 1400 mmfa |
|
|
|
|
Profile cover for aluminum profile for TopScan-S Series, Length 1400 mmfa |
|
|
|
|
End cover for series TopScan-S aluminum profile sectionfa |
|
|
|
|
Polyurethane foam seal for increased degree of protection to IP54, Simple insertion into the TopScan-S profile section behind the capfa |
|
|
|
|
Bearing block for AIR17-S sensor module for installation in TopScan-S profile sectionfa |
|
|
|
|
Flexible metal conduit, Protection against contamination and damagefa |
|
|
|
|
Adjustment accessories series TopScan-Sfa |
|
|
|
|
Connecting cable for sensor modules, Length 240 mmfa |
|