Serviceline Industrial Sensors
Serviceline Explosion Protection

Distributor VAZ-CHAIN-BU/BN70MM/1,0-25

VAZ-CHAIN-BU/BN70MM/1,0-25
  • For signal connection in control cabinets
  • Using the multi-purpose twist-on connectors, the daisy chain can be adjusted to the required length and installed in the field
  • Conveniently replace, install or remove individual modules without disrupting wiring

Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.

Ladda ned datablad som PDF::


Utdrag ur datablad: Tekniska data för  VAZ-CHAIN-BU/BN70MM/1,0-25

Product Description
25-point wiring link for control cabinet modules with screw terminals
General specifications
UL File NumberE223176
Electrical specifications
Nominal voltage48 V
Current loading capacity8 A at 40 °C
DIN VDE 0298 Part 4
HD 516/VDE 0298-300
Ambient conditions
Ambient temperature-30 ... 80 °C (-22 ... 176 °F) fixed installation
Mechanical specifications
Core cross sectionFine-stranded copper 1 mm2
Bending radiusmovable installation: 4 x external diameter
fixed installation: 2 x external diameter
Material
Core insulationPVC
CableH05V-K, rated voltage 300/500 V
Colorbrown, blue
Connection possibilitiesSuitable for screw terminals
Cable length25 x 7 cm + 1 m
Flammability
CableFlame-retardant as per IEC 60332-1-2

Classifications

SystemClasscode
ECLASS 13.027279090
ECLASS 12.027279090
ECLASS 11.027279090
ECLASS 10.0.127279090
ECLASS 9.027279090
ECLASS 8.027279090
ECLASS 5.127279290
ETIM 9.0EC003015
ETIM 8.0EC003015
ETIM 7.0EC003015
ETIM 6.0EC003015
ETIM 5.0EC003015
UNSPSC 12.131251501

Details: VAZ-CHAIN-BU/BN70MM/1,0-25

Informative Literature: VAZ-CHAIN-BU/BN70MM/1,0-25

Language Selection:
LiteratureLanguageFile TypeFile Size
Application Report - Efficient Wiring Method for Control CabinetsENGPDF896 KB

Approvals: VAZ-CHAIN-BU/BN70MM/1,0-25

Language Selection:
CertificatesCert No.LanguageFile TypeFile Size
US CA ULE223176ALLLINK---

Associated Products: VAZ-CHAIN-BU/BN70MM/1,0-25

Accessory of

AS-Interface advanced repeater with terminatorfa

KE switch cabinet module, 4 inputs and 4 outputsfa

KE switch cabinet module
4 inputs (PNP)fa

KE1-Safety module for the control cabinet
2 safety-related inputs and
2 conventional electronic outputsfa

KE1-Safety module for the control cabinet
2 safety-related inputs and
2 conventional electronic outputsfa

KE3 control cabinet module, 4 inputs, 1 control-safe relay outputfa

2-channel, 115/230 V AC supply, 3-wire PNP/NPN sensor or push-pull input, Relay contact output, DIP switch selectable functions, Minimum/maximum control, Up to SIL 2 acc. to IEC/EN 61508 / IEC/EN 61511, Housing width: 20 mm, Number of channels: 2-channel, Interval relay, Min./max. control, Safety Integrity Level (SIL): SIL 2, Rated voltage: 90 ... 253 V AC , 45 ... 65 Hz, Field device: 3-wire sensor, Field device [2]: Push-pull (4 in 1) output, Type: 2 x relay (change-over contact)pa

KE1 switch cabinet module
4 inputs and 2 outputsfa
Safe contact expansion, 2 channels, 8 contact setsfa
KE switch cabinet module, 4 inputs (PNP) and 3 relay outputsfa
AS-Interface power extenderfa
Bracket for VAA-3E-HH30-J-S-V1fa
Safety monitor, three 2-channel secure inputs, two secure outputsfa
Safety Monitor, 8 decentralized output circuitsfa
Safety Monitor, 8 decentralized output circuitsfa
KE4 switch cabinet module for rotary encoder
Adapter for 2 rotary encoder to rotation speed monitor and control panelfa
Cabinet module
4 inputs and 4 outputsfa
KE switch cabinet module
4 inputs and 3 outputsfa
KE control cabinet module
2 analog inputsfa
KE switch cabinet module, 4 inputs (PNP) and 4 relay outputsfa
KE switch cabinet module, 4 inputs (PNP) and 4 relay outputsfa
2-channel signal conditioner, Universal usage at different power supplies, Dry contact or NAMUR inputs, Input frequency 1 mHz ... 1 kHz, Current output 0/4 mA ... 20 mA, Relay contact and transistor output, Start-up override, Configurable by PACTware or keypad, Line fault detection (LFD), Rated voltage: 20 ... 90 V DC / 48 ... 253 V AC 50 ... 60 Hz, Input I, II: 2-wire sensor, sensor acc. to EN 60947-5-6 (NAMUR) or mechanical contact, Output I, II: signal, relay, Output V: analogpa
KE switch cabinet module, 4 inputs and 4 outputsfa
KE1 switch cabinet module, 4 inputs and 4 outputsfa
KE1 switch cabinet module, 4 inputsfa
KE1 switch cabinet module, 4 inputs and 4 outputsfa
Control cabinet module
Data couplerfa
KE1 safety module for the control cabinet, 2 Safety-related inputsfa
KE3 switch cabinet module, 1 safety-related electronic output, 4 standard inputs, 2 standard outputsfa
KE4 control cabinet module
2 inputs for incremental rotary encodersfa
KE4 control cabinet module for rotary encoders
2 safe inputs und 2 safe outputsfa
KE4 switch cabinet module
8 safety-related electronic outputs, each switchable with a standard output, 8 standard inputsfa
KE switch cabinet module, 4 inputs and 3 outputsfa
Matching System Components
1-channel signal conditioner, 24 V DC supply, Input for 2- or 3-wire sensors, Input frequency 10 mHz ... 50 kHz, Relay contact output, Start-up override and restart inhibit, Configurable by DIP switches and software, Connection via screw terminals, Number of channels: 1-channel, Restart inhibit, Start-up override, Signal type: Digital Input, Rated voltage: 16.8 ... 31.2 V DC, Field device: NAMUR sensor, Field device [2]: volt-free contact, Field device [3]: 2-wire DC sensor, Field device [4]: SN sensorpa