Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.
Ladda ned datablad som PDF::
Product Description |
---|
AS-Interface power supply, data decoupling, 8 A |
General specifications | ||
---|---|---|
UL File Number | E223176 | |
MTBF | 100 a | |
Indicators/operating means | ||
Reset push-button switch | FUSE mode reset | |
Power selection switch | changeover switch for 115 V AC/230 V AC | |
LED Overload | red LED, flashes in the FUSE mode | |
LED IR on | red LED: ON: Plug-in jumper position 2-3 OFF: Plug-in jumper position 1-2 |
|
Plug-in jumper | Position 1-2: Communication Mode Position 2-3: IR addressing |
|
LED AS-i ok | operating display; LED green | |
Electrical specifications | ||
Fusing | T8A/250 V AC HBC (not accessible) | |
Capacity factor | > 0.5 | |
Rated operating voltage | nominal: 100 ... 120 V AC/220 ... 240 V AC (front end selectable) permissible: 85 ... 132 V AC/184 ... 264 V AC/230 ... 375 V DC |
|
Rated operating current | 6,0 A (Switch position 115 V) 2.8 A (Switch position 230 V) |
|
Supply frequency | 47 ... 63 Hz or DC | |
Efficiency | typ. 92 % (at 230 V AC/8 A) | |
Surge protection | limited to max. 55 V | |
Output | ||
Short-circuit protection/overload | FUSE Mode (2 ... 5 s current, then trips) | |
Current limit | > 8.4 A | |
Voltage | 30.55 V DC ± 3 % | |
Current | 8 A | |
Galvanic isolation | overvoltage category III | |
Residual ripple | ≤ 50 mVss (500 kHz bandwidth, 50-Ω-measurement with ohmic load) | |
Short-circuit current | 12 ... 25 A (max. 5 s) | |
Standard conformity | ||
Electromagnetic compatibility | emitted interference in accordance with EN 50081-2 class B (EN 55011, EN 55022) noise immunity in accordance with EN 61000-6-2, EN 61000-4-2 to EN 61000-4-6, EN 61000-4-11 |
|
Ambient conditions | ||
Ambient temperature | -10 ... 70 °C (14 ... 158 °F) (Measured 25 mm below the device) from 60° C 6W/°C power recovery necessary |
|
Storage temperature | -25 ... 85 °C (-13 ... 185 °F) | |
Pollution degree | 2 | |
Mechanical specifications | ||
Degree of protection | IP20 according to EN 60529 | |
Protection class | 1 (IEC 60536); Protective conductor connection necessary | |
Connection | Connection terminals, max. conductor cross-section flexible: 0.5 ... 4 mm2 fixed: 0.5 ... 6 mm2 stripped length 7 mm, connector sleeves are permissible |
|
Material | ||
Housing | metal | |
Mass | approx. 890 g | |
Dimensions | ||
Height | 124 mm | |
Width | 91 mm | |
Length | 102 mm |
System | Classcode |
---|---|
ECLASS 13.0 | 27040301 |
ECLASS 12.0 | 27040301 |
ECLASS 11.0 | 27040301 |
ECLASS 10.0.1 | 27040301 |
ECLASS 9.0 | 27040301 |
ECLASS 8.0 | 27040301 |
ECLASS 5.1 | 27040301 |
ETIM 9.0 | EC002540 |
ETIM 8.0 | EC002540 |
ETIM 7.0 | EC002540 |
ETIM 6.0 | EC002540 |
ETIM 5.0 | EC002540 |
UNSPSC 12.1 | 39121004 |
Brief Instructions | Language | File Type | File Size |
---|---|---|---|
Instruction leaflet / Beipackzettel | ALL | 181 KB | |
Manual / Handbuch | ALL | 86 KB |
CAD | Language | File Type | File Size |
---|---|---|---|
CAD 3-D / CAD 3-D | ALL | STP | 10419 KB |
CAD Portal / CAD Portal | ALL | LINK | --- |
CAE | |||
CAE EPLAN Data Portal / CAE EPLAN Data Portal | ALL | LINK | --- |
CAE EPLAN macro EDZ / CAE EPLAN Makro EDZ | ALL | EDZ | 40 KB |
Certificates | Cert No. | Language | File Type | File Size |
---|---|---|---|---|
US CA UL | CoC E223176 RptRef E223176-20070416 | ALL | 444 KB | |
US CA UL | E223176 | ALL | LINK | --- |
Declaration of Conformity | ||||
EU Declaration of Conformity (P+F) / EU-Konformitäterklärung (P+F) | DOC-4814A | ALL | 163 KB |
Accessories | ||||||
---|---|---|---|---|---|---|
|