SMART Current Driver HiD2038

HiD2038
  • 2-channel isolated barrier
  • 24 V DC supply (bus powered)
  • Current output up to 750 Ω load
  • SMART I/P and valve positioners
  • Line fault detection (LFD)
  • Up to SIL 2 acc. to IEC 61508

Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.

Caractéristiques techniques  HiD2038

General specifications
Signal typeAnalog output
Functional safety related parameters
Safety Integrity Level (SIL)SIL 2
Supply
ConnectionSL1: 1a(-), 1b(-); 2a(+), 2b(+)
Rated voltage20.4 ... 30 V DC bus powered via Termination Board
Rated current40 mA at 24 V, 20 mA output (per channel)
Power dissipation0.85 W at 24 V (per channel)
Input
Connection sidecontrol side
ConnectionSL1: 8a(+), 7a(-); 10a(+), 9a(-)
Input current4 ... 20 mA , reverse polarity protected
Signal levelinput voltage drop < 4 V with field wiring intact
input current < 1.2 mA with field wiring open
Output
Connection sidefield side
ConnectionSL2: 5a(+), 5b(-); 1a(+), 1b(-)
Load0 ... 750 Ω
Output signal4 ... 20 mA
Ripple15 mV eff
Response time50 ms , 10 ... 90 % step change
Line fault detectionbreakage, load > 100 kΩ, short-circuit, load < 70 Ω
Fault indication output
ConnectionSL1: 6b
Output typeopen collector transistor (internal fault bus)
Transfer characteristics
Accuracy< ± 0.1 % of full-scale value
Influence of temperature< ± 0.01 %/K
Frequency range0.5 ... 40 kHz within 3 db, (-6 db at 100 kHz) for use with SMART positioners using HART protocol
Influence of load< ± 0.1 % of full-scale value from 0 ... 750 Ω
Linearity< ± 0.1 % of full-scale value
Galvanic isolation
Input/power supplyfunctional insulation acc. to DIN EN 50178, rated insulation voltage 50 Veff
Input/inputfunctional insulation acc. to DIN EN 50178, rated insulation voltage 50 Veff
Indicators/settings
Display elementsLEDs
Labelingspace for labeling at the front
Directive conformity
Electromagnetic compatibility
Directive 2014/30/EUEN 61326-1:2013 (industrial locations)
Conformity
Electromagnetic compatibilityNE 21:2006
For further information see system description.
Degree of protectionIEC 60529
Ambient conditions
Ambient temperature-20 ... 60 °C (-4 ... 140 °F)
Relative humidity5 ... 90 %, non-condensing up to 35 °C (95 °F)
Mechanical specifications
Degree of protectionIP20
Massapprox. 140 g
Dimensions18 x 106 x 128 mm (0.7 x 4.2 x 5 inch)
Height106 mm
Width18 mm
Length128 mm
Mountingon termination board
Codingpin 1 and 3 trimmed
For further information see system description.
Data for application in connection with hazardous areas
EU-type examination certificateCESI 02 ATEX 086
MarkingEx-Hexagon II (1)G [Ex ia Ga] IIC , Ex-Hexagon II (1)D [Ex ia Da] IIIC
OutputEx ia, Ex iaD
Voltage26 V
Current93 mA
Power605 mW
Supply
Maximum safe voltage250 V AC (Attention! Um is no rated voltage.)
CertificatePF 11 CERT 2109 X
MarkingEx-Hexagon II 3G Ex nA IIC T4 Gc [device in zone 2]
Galvanic isolation
Input/Outputsafe electrical isolation acc. to EN 60079-11: 2007, voltage peak value 375 V
Output/power supplysafe electrical isolation acc. to EN 60079-11: 2007, voltage peak value 375 V
Output/Outputsafe electrical isolation acc. to EN 60079-11:2007, voltage peak value 60 V
Directive conformity
Directive 2014/34/EUEN 60079-0:2012+A11:2013 , EN 60079-11:2012 , EN 60079-15:2010
International approvals
CSA approval
Control drawing366-005CS-12B (cCSAus)
IECEx approvalIECEx TUN 04.0012
Approved for[Ex ia] IIC
General information
Supplementary informationObserve the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com.

Classifications

SystemClasscode
ECLASS 13.027210120
ECLASS 12.027210120
ECLASS 11.027210120
ECLASS 10.0.127210120
ECLASS 9.027210120
ECLASS 8.027210120
ECLASS 5.127210120
ETIM 9.0EC002653
ETIM 8.0EC002653
ETIM 7.0EC002653
ETIM 6.0EC002653
ETIM 5.0EC001485
UNSPSC 12.132101514

Details: HiD2038

Datasheet: HiD2038

DatasheetType de fichierTaille
Datasheet HiD2038PDF297 KB
Datenblatt HiD2038PDF298 KB

Documents: HiD2038

ManualsType de fichierTaille
ManualPDF199 KB
System ManualPDF5438 KB
SystemhandbuchPDF5450 KB
Instruction manuals
ИнструкцииPDF169 KB
Instruction manual / BetriebsanleitungPDF320 KB
Návod k poużitíPDF163 KB
Instruktions manualPDF163 KB
Instruction manualPDF168 KB
KasutusjuhendPDF159 KB
KäyttöohjePDF158 KB
Manuel d'instructionsPDF165 KB
BetriebsanleitungPDF170 KB
Οδηγίες χρήσηςPDF173 KB
HandleidingPDF164 KB
Instruction manual / BetriebsanleitungPDF162 KB
Használati útmutatóPDF164 KB
Manuale di istruzioniPDF163 KB
Lietošanas pamācībaPDF161 KB
Instrukciju vadovasPDF162 KB
Instrukcja obsługiPDF166 KB
Manual de instruçõesPDF164 KB
Manual de utilizarePDF164 KB
Návod na poużitiePDF163 KB
Navodila za uporaboPDF161 KB
Manual de instruccionesPDF164 KB
ManualPDF160 KB

CAD+CAE: HiD2038

CADType de fichierTaille
CAD 2-D / CAD 2-DZIP16364 KB
EPLAN
EPLAN macros H-System devices (EMA) / EPLAN-Makros Geräte H-System (EMA)ZIP3536 KB

Approvals+Certificates: HiD2038

CertificatesType de fichierTaille
Canada, USA CSAPDF136 KB
Europe CESI ATEX Category (1) D ATEX Category (1) GPDF3887 KB
South Africa MASCPDF662 KB
TUV Nord IECEx Certificate of ConformityLINK---
exida Functional Safety AssessmentPDF514 KB
Control Drawings
Control drawing CSA / Control drawing CSAPDF98 KB
Declaration of Conformity
EU Declaration of Conformity (P+F) / EU-Konformitäterklärung (P+F)PDF49 KB
Safety Products Selector

Choose from various selection criteria like safety integrity level, performance level, device function, and signal type and find the SIL/PL assessed device that you are looking for.