Switch Amplifier HiD2842

HiD2842
  • 2-channel isolated barrier
  • 24 V DC supply (bus powered)
  • Dry contact or NAMUR inputs
  • Usable as signal splitter (1 input and 2 outputs)
  • 2 passive transistor outputs per channel
  • Line fault detection (LFD)
  • Up to SIL 2 acc. to IEC 61508

Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.

Caractéristiques techniques  HiD2842

General specifications
Signal typeDigital Input
Functional safety related parameters
Safety Integrity Level (SIL)SIL 2
Supply
ConnectionSL1: 1a(-), 1b(-); 2a(+), 2b(+)
Rated voltage20.4 ... 30 V DC bus powered via Termination Board
Rated current15 mA at 24 V (per channel)
Power dissipation0.35 W at 24 V (per channel)
Input
Connection sidefield side
ConnectionSL2: 5a(+), 5b(-); 1a(+), 1b(-)
Rated valuesacc. to EN 60947-5-6 (NAMUR)
Connectable sensor typespotential free contact or proximity sensor
Switching pointcontact open 0.2 ... 1.2 mA, contact closed 2.1 ... 6.5 mA
Line fault detectionbreakage 0 ... 0.2 mA, short-circuit 6.5 mA ... maximum value
Output
Connection sidecontrol side
ConnectionSL1: 8a(+), 7a(-), 8b(+), 7b(-); 10a(+), 9a(-), 9b(+), 10b(-)
Rated voltage30 V
Rated current50 mA
Outputtwo optocoupled transistors per channel
Signal level1-signal: (external voltage) -1 V
0-signal: blocked output (off-state current max. 50 µA, typical 5 µA)
Fault indication output
ConnectionSL1: 6b
Output typeopen collector transistor (internal fault bus)
Transfer characteristics
Switching frequency< 2 kHz
Galvanic isolation
Output/power supplyfunctional insulation acc. to DIN EN 50178, rated insulation voltage 50 Veff
Output/Outputfunctional insulation acc. to DIN EN 50178, rated insulation voltage 50 Veff
Indicators/settings
Display elementsLEDs
Control elementsDIP switch
Factory settinginput close, transistor closed, lead fault detection enabled
Configurationvia DIP switches
Labelingspace for labeling at the front
Directive conformity
Electromagnetic compatibility
Directive 2014/30/EUEN 61326-1:2013 (industrial locations)
Conformity
Galvanic isolationEN 50178
Electromagnetic compatibilityNE 21:2006
For further information see system description.
Degree of protectionIEC 60529
Ambient conditions
Ambient temperature-20 ... 60 °C (-4 ... 140 °F)
Relative humidity5 ... 90 %, non-condensing up to 35 °C (95 °F)
Mechanical specifications
Degree of protectionIP20
Massapprox. 140 g
Dimensions18 x 106 x 128 mm (0.7 x 4.2 x 5 inch)
Height106 mm
Width18 mm
Length128 mm
Mountingon termination board
Codingpin 1 and 2 trimmed
For further information see system description.
Data for application in connection with hazardous areas
EU-type examination certificateCESI 02 ATEX 086
MarkingEx-Hexagon II (1)G [Ex ia Ga] IIC , Ex-Hexagon II (1)D [Ex ia Da] IIIC
InputEx ia, Ex iaD
Voltage13.2 V
Current20 mA
Power66 mW
Supply
Maximum safe voltage250 V AC (Attention! Um is no rated voltage.)
CertificatePF 11 CERT 2109 X
MarkingEx-Hexagon II 3G Ex nA IIC T4 Gc [device in zone 2]
Galvanic isolation
Input/inputsafe electrical isolation acc. to EN 60079-11:2007, voltage peak value 60 V
Input/Outputsafe electrical isolation acc. to EN 60079-11: 2007, voltage peak value 375 V
Input/power supplysafe electrical isolation acc. to EN 60079-11: 2007, voltage peak value 375 V
Directive conformity
Directive 2014/34/EUEN 60079-0:2012+A11:2013 , EN 60079-11:2012 , EN 60079-15:2010
International approvals
CSA approval
Control drawing366-005CS-12B (cCSAus)
IECEx approvalIECEx TUN 04.0012
Approved for[Ex ia] IIC
General information
Supplementary informationObserve the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com.

Classifications

SystemClasscode
ECLASS 13.027210121
ECLASS 12.027210121
ECLASS 11.027210121
ECLASS 10.0.127210121
ECLASS 9.027210121
ECLASS 8.027210121
ECLASS 5.127210121
ETIM 9.0EC001485
ETIM 8.0EC001485
ETIM 7.0EC001485
ETIM 6.0EC001485
ETIM 5.0EC001485
UNSPSC 12.132101514

Details: HiD2842

Cette barrière isolée est utilisée pour des applications de sécurité intrinsèque. Elle transfère des signaux numériques (détecteurs NAMUR/contacts mécaniques) d'une zone à risque d'explosion vers une zone non dangereuse.

Chaque détecteur ou commutateur de proximité commande deux transistors passifs pour une utilisation en zone non dangereuse. La sortie du module change d'état lorsque le signal d'entrée change d'état. Il est possible d'inverser l'état de sortie normal à l'aide des commutateurs de sélection situés sur le côté de l'appareil.

La détection de défaut de ligne (LFD) peut être sélectionnée et désactivée à l'aide du commutateur de sélection.

En cas d'erreur, le transistor est mis hors tension et les LED signalent le défaut. Un bus de sortie défaut séparée est disponible. Les défauts peuvent être surveillés via une platine d'indication de défaut.

Ce module est monté sur une platine de connexion HiD.

Datasheet: HiD2842

DatasheetType de fichierTaille
Datasheet HiD2842PDF355 KB
Datenblatt HiD2842PDF362 KB

Documents: HiD2842

ManualsType de fichierTaille
ManualPDF431 KB
System ManualPDF5438 KB
SystemhandbuchPDF5450 KB
Instruction manuals
ИнструкцииPDF169 KB
Instruction manual / BetriebsanleitungPDF320 KB
Návod k poużitíPDF163 KB
Instruktions manualPDF163 KB
Instruction manualPDF168 KB
KasutusjuhendPDF159 KB
KäyttöohjePDF158 KB
Manuel d'instructionsPDF165 KB
BetriebsanleitungPDF170 KB
Οδηγίες χρήσηςPDF173 KB
HandleidingPDF164 KB
Instruction manual / BetriebsanleitungPDF162 KB
Használati útmutatóPDF164 KB
Manuale di istruzioniPDF163 KB
Lietošanas pamācībaPDF161 KB
Instrukciju vadovasPDF162 KB
Instrukcja obsługiPDF166 KB
Manual de instruçõesPDF164 KB
Manual de utilizarePDF164 KB
Návod na poużitiePDF163 KB
Navodila za uporaboPDF161 KB
Manual de instruccionesPDF164 KB
ManualPDF160 KB

CAD+CAE: HiD2842

CADType de fichierTaille
CAD 2-D / CAD 2-DZIP16364 KB
EPLAN
EPLAN macros H-System devices (EMA) / EPLAN-Makros Geräte H-System (EMA)ZIP3536 KB
Safety Products Selector

Choose from various selection criteria like safety integrity level, performance level, device function, and signal type and find the SIL/PL assessed device that you are looking for.