8-channel, Inputs Ex ia, Installation in suitable enclosures in Zone 1, Module can be exchanged under voltage (hot swap), Explosion protection: Ex ia, Connection: NAMUR sensor, Connection [2]: volt-free contact
4-channel, Inputs Ex ia, Installation in suitable enclosures in Zone 1, Module can be exchanged under voltage (hot swap), Explosion protection: Ex ia, Field device: pressure converter, Field device [2]: flow converter, Field device [3]: level converter, Field device [4]: Temperature Converter, Connection: 2-wire transmitter, Connection [2]: 3-wire transmitter, Connection [3]: 4-wire transmitter, HART communication
4-channel, Inputs Ex ia, Installation in suitable enclosures in Zone 1, Module can be exchanged under voltage (hot swap), Explosion protection: Ex ia, Field device: resistance thermometer, Field device [2]: slide-wire sensors, Field device [3]: potentiometer, Connection: 2-wire sensor, Connection [2]: 3-wire sensor, Connection [3]: 4-wire sensor
4-channel, Inputs Ex ia, Outputs Ex ia, Installation in suitable enclosures in Zone 1, Module can be exchanged under voltage (hot swap), Explosion protection: Ex ia, Field device: pressure converter, Field device [2]: flow converter, Field device [3]: level converter, Field device [4]: Temperature Converter, Connection: 2-wire transmitter, HART communication
Interface between the I/O modules and the PCS/PLC, Com unit for 80 analog or 184 digital channels, Communication via PROFIBUS DP, Installation in suitable enclosures in Zone 1, Fieldbus type: PROFIBUS DP/DP-V1
Power supply for 24 V DC, Installation in suitable enclosures in Zone 1, Module can be exchanged under voltage (hot swap), Voltage: 5.4 V DC +/- 5% , , 12 V DC + 4/- 2%
Active termination of the fieldbus and passive termination of the service bus, Installation in suitable enclosures in Zone 1, Module can be exchanged under voltage in Zone 1 (hot swap; be aware bus operation may be affected)
8-channel, Contact 30 V AC/DC, 1 A, 30 W, 30 VA (resistive load), Mounting in Zone 2, Class I/Div.2 or in the safe area, Positive or negative logic selectable, Explosion protection: Ex nA nC
Interface between the I/O modules and the PCS/PLC, Com unit for 80 analog or 184 digital channels, Communication via PROFIBUS DP, Mounting in Zone 2, Class I/Div.2 or in the safe area, Fieldbus type: PROFIBUS DP/DP-V1
Interface between the I/O modules and the PCS/PLC, Com unit for 80 analog or 184 digital channels, Communication via MODBUS RTU, Mounting in Zone 2, Class I/Div.2 or in the safe area, Fieldbus type: MODBUS RTU
Interface between the I/O modules and the PCS/PLC, Com unit for 80 analog or 184 digital channels, Communication via MODBUS TCP, Mounting in Zone 2, Class I/Div.2 or in the safe area, Fieldbus type: MODBUS TCP
Power supply for 24 V, Permits vertical or horizontal mounting in Zone 2, Use three power supplies for redundancy, Galvanic isolation to mains, Voltage: 5.4 V DC +/- 5% , , 12 V DC + 4/- 2%
Spring terminal, For LB and FB modules, 6-pole, Labeled 1 ... 6, Color blue, For Ex ia or Ex ib applications, Construction type: spring terminal
Spring terminal, For LB and FB modules, 8-pole, Labeled 1 ... 8, Color blue, For Ex ia or Ex ib applications, Construction type: spring terminal
Spring terminal, For LB and FB modules, 2 x 8-pole, Labeled 1 ... 8 and 9 ... 16, Color blue, For Ex ia or Ex ib applications, Construction type: spring terminal
Front screw terminal, For LB and FB modules, 6-pole, Labeled 1 ... 6, Color blue, For Ex ia or Ex ib applications, Construction type: front screw terminal
Front screw terminal, For LB and FB modules, 8-pole, Labeled 1 ... 8, Color blue, For Ex ia or Ex ib applications, Construction type: front screw terminal
Front screw terminal, For LB and FB modules, 2 x 8-pole, Labeled 1 ... 8 and 9 ... 16, Color blue, For Ex ia or Ex ib applications, Construction type: front screw terminal
Spring terminal, For LB modules, 8-pole, Color blue, For Ex ia or Ex ib applications, For wire end ferrules without plastic sleeve only, Construction type: spring terminal
1-channel, Input Ex ia, Installation in suitable enclosures in Zone 1, Module can be exchanged under voltage (hot swap), Explosion protection: Ex ia, Function: Counter , Function [2]: frequency, Function [3]: direction of rotation, Connection: NAMUR sensor, Connection [2]: volt-free contact
8-channel, Inputs with plug-in Ex e terminals, Installation in suitable enclosures in Zone 1, Module can be exchanged under voltage (hot swap), Explosion protection: Ex e connection, Connection: NAMUR sensor, Connection [2]: volt-free contact, Connection [3]: active binary signal 24 V DC
1-channel, 1 digital output, 2 digital inputs, Inputs and output Ex ia, Installation in suitable enclosures in Zone 1, Explosion protection: Ex ia, Field device: Solenoid Valve, Field device [2]: audible alarm, Field device [3]: visual alarm
1-channel, Input Ex ia, Installation in suitable enclosures in Zone 1, Module can be exchanged under voltage (hot swap), Explosion protection: Ex ia, Field device: pressure converter, Field device [2]: flow converter, Field device [3]: level converter, Field device [4]: Temperature Converter, Connection: 2-wire transmitter, Connection [2]: 3-wire transmitter, Connection [3]: 4-wire transmitter, HART communication
1-channel, Output Ex ia, Installation in suitable enclosures in Zone 1, Module can be exchanged under voltage (hot swap), Explosion protection: Ex ia, Field device: Proportional Valve, Field device [2]: I/P converters, Field device [3]: on-site display
4-channel, Outputs Ex ia, Installation in suitable enclosures in Zone 1, Module can be exchanged under voltage (hot swap), Explosion protection: Ex ia, Field device: Proportional Valve, Field device [2]: I/P converters, Field device [3]: on-site display
4-channel, Inputs Ex ia, Installation in suitable enclosures in Zone 1, Module can be exchanged under voltage (hot swap), Explosion protection: Ex ia, Field device [2]: Thermocouple, Field device [4]: mV source
2-channel, Outputs Ex ia, Installation in suitable enclosures in Zone 1, Module can be exchanged under voltage (hot swap), Explosion protection: Ex ia, Field device: Solenoid Valve, Field device [2]: audible alarm, Field device [3]: visual alarm
2-channel, Outputs wired to Ex e terminals, Installation in suitable enclosures in Zone 1 or Zone 21, Positive or negative logic selectable
4-channel, Outputs wired to Ex e terminals, Installation in suitable enclosures in Zone 1 or Zone 21, Positive or negative logic selectable
8-channel, Installation in suitable enclosures in Zone 1, Positive or negative logic selectable, Simulation mode for service operations (forcing), Explosion protection: Ex e connection
4-channel, Inputs Ex ia, Outputs Ex ia, Installation in suitable enclosures in Zone 1, Module can be exchanged under voltage (hot swap)
4-channel, Inputs with plug-in Ex e terminals, Installation in suitable enclosures in Zone 1, Module can be exchanged under voltage (hot swap), Explosion protection: Ex e connection, Field device: pressure converter, Field device [2]: flow converter, Field device [3]: level converter, Field device [4]: Temperature Converter, Connection: 2-wire transmitter, HART communication
4-channel, Inputs with plug-in Ex e terminals, Installation in suitable enclosures in Zone 1, Module can be exchanged under voltage (hot swap)
Interface between the I/O modules and the PCS/PLC, Com unit for 80 analog or 184 digital channels, Communication via PROFIBUS DP, Module can be exchanged under voltage (hot swap), Fieldbus type: PROFIBUS DP/DP-V1
Interface between the I/O modules and the PCS/PLC, Com unit for 80 analog or 184 digital channels, Communication via MODBUS RTU, Installation in suitable enclosures in Zone 1, Fieldbus type: MODBUS RTU
Interface between the I/O modules and the PCS/PLC, Com unit for 20 analog or 40 digital channels, Communication via FOUNDATION Fieldbus H1, HART communication via service bus, Fieldbus type: FOUNDATION Fieldbus H1
Interface between the I/O modules and the PCS/PLC, Communication via MODBUS TCP, Installation in suitable enclosures in Zone 1, Module can be exchanged under voltage (hot swap), Fieldbus type: MODBUS TCP
Interface between the I/O modules and the PCS/PLC, Com unit for 80 analog or 184 digital channels, Communication via MODBUS TCP, Installation in suitable enclosures in Zone 1, Fieldbus type: MODBUS TCP
Communication via PROFINET, Installation in suitable enclosures in Zone 1, Interface between the I/O modules and the PCS/PLC, Non-volatile memory for configuration and parameter settings, Fieldbus type: PROFINET
Power supply for 100 - 230 V AC, Suitable for the supply of FOL, field products (analyzers, level meters etc.), Installation in suitable enclosures in Zone 1, Module can be exchanged under voltage (hot swap), Voltage: 24 V DC +/- 3% (Connectors 5, 12) , 23 V DC +/- 3% decoupled via diode (Connectors 5, 13)
Preconfigured enclosures for engineered FB systems, Installation in Zone 1 and Zone 21, Installation in Zone 2 and Zone 22, Max. 10 slots for I/O modules, Number of modules: 10, Material: Stainless steel, I/O modules (single width): max. 10, I/O modules (dual width): max. 5, Redundancy: possible
Preconfigured enclosures for engineered FB systems, Installation in Zone 1 and Zone 21, Installation in Zone 2 and Zone 22, Max. 10 slots for I/O modules, Number of modules: 10, Material: Stainless steel, I/O modules (single width): max. 10, I/O modules (dual width): max. 5, Redundancy, Redundancy
Multi range power supply 90 ... 253 V AC, Suitable for the supply of 24 I/O modules and 1 bus coupler, Use two power supplies for redundancy, Installation in suitable enclosures in Zone 1, Voltage: 5.4 V DC +/- 5% , , 12 V DC +/- 3%
49 / 137