Ex d certified, Aluminum alloy, Installation in Zone 1, Zone 2, Zone 21 and Zone 22, Degree of protection IP66, Thermo-resistant tempered glass windowpa
Ex d certified, Aluminum alloy, Installation in Zone 1, Zone 2, Zone 21 and Zone 22, Degree of protection IP66, Thermo-resistant tempered glass windowpa
Ex d certified, Aluminum alloy, Installation in Zone 1, Zone 2, Zone 21 and Zone 22, Degree of protection IP66, Thermo-resistant tempered glass windowpa
Stopping plug for unused cable entries, Brass nickel-plated or stainless steel, NPT versions available, Without head, installation by means of allen key, Ex db, Ex eb and Ex tb certified, Suitable for operation in Zone 1, Zone 2, Zone 21 and Zone 22, Suitable for operation in Class I, Zone 1/2/22, Suitable for operation in Class I, Division 2 when installed in accordance with NEC501.10(B)(2), Degree of protection IP66 / IP68, UL Type 4X, Thread size (TD): see data tablepa
Stopping plug for unused cable entries, Brass nickel-plated or stainless steel, Metric and NPT versions available, Hexagon head, Ex db, Ex eb and Ex tb certified, Seal chloroprene or silicone, Suitable for operation in Zone 1, Zone 2, Zone 21 and Zone 22, Suitable for operation in Class I, Zone 1/2/22, Suitable for operation in Class I, Division 2 when installed in accordance with NEC501.10(B)(2), Degree of protection IP66 / IP68, UL Type 4Xpa
Stopping plug for unused cable entries, High impact-resistant polyamide material, Ex eb and Ex tb certified, Suitable for operation in Zone 1, Zone 2, Zone 21 and Zone 22, Full impact resistance of 7 J according to IEC/EN 60079-0 for the full range without limitations, Ambient temperature: chloroprene seal: -40 ... 70 °C (-40 ... 158 °F) silicone seal: -60 ... 70 °C (-76 ... 158 °F), Thread size (TD): see data table, Stopping plug: high impact-resistant polyamidepa
暂不可售: Surge protection for 2 supply lines, Type 3 acc. to EN 61643-11, Nominal voltage 120 V AC, Pre-wired unit, Operating state and fault indication of every protected line, Fault indication output, DIN rail mountable, Device type: type 3 acc. to EN 61643-11:2013 class III acc. to IEC 61643-1:2011, Number of protected supply lines: 2pa
暂不可售: Protection module for 1 supply line, Type 2 acc. to EN 61643-11, Exchange device for surge protection barrier M-LB-*.275*.D, Easy replacement of protection modules wihtout tools, High discharge capacity, Module can be exchanged under voltage (hot swap), Device type: type 2 acc. to EN 61643-11 class II acc. to IEC 61643-1, Number of protected supply lines: 1pa
暂不可售: 4-channel, On/Off delay, Mounting in Zone 2, Class I/Div.2 or in the safe area, Positive or negative logic selectable, Explosion protection: Ex nA nCpa