1-channel signal conditioner, 24 V DC supply, Logic input 20.5 V DC ... 26.4 V DC, Recommended connectable voltage 8 V DC ... 60 V DC, Relay contact output for energized to safe function , Line fault transparency (LFT), Diagnostic function, Up to SIL 3 acc. to IEC/EN 61508, Housing width: 20 mm, Number of channels: 1-channel, Diagnostics function, Line fault transparency, ETS function (energized to safe), Safety Integrity Level (SIL): SIL 3, Systematic capability (SC): SC 3pa
Software user interface for Advanced Diagnostic Modules, Simultaneous access to all ADMs of a plant, Embedded expert system gives pointed advice in clear text, Includes Commissioning Wizard, data historian, oscilloscope..., For FOUNDATION Fieldbus H1 and PROFIBUS PA, Automatic setup of diagnostic systempa
Fieldbus Power Hub, Motherboard for Gateway and Power Supply Modules
4 segments, simplex, individual modules per segment, For PROFIBUS PA, For gateway and power supply modules, High-power trunk: Live work on devices in any hazardous area, Optional advanced diagnostics, IECEx approval, International, Europe, USA, Canada, Device coupler location: non-explosion hazardous area Zone 2 - high-power trunk Zone 1 - high-power trunk Division 2 - high-power trunk Division 1 - high-power trunk, Device coupler location [2]: Zone 2 - high-power trunkpa
FieldConnex® FieldBarrier®, 8 ... 12 outputs Ex ia IIC, FISCO and Entity, Advanced fault isolation and diagnostics at the spur, FieldBarrier in Zone 1/Div. 2, Instruments in Zone 0...1/Div. 1, For FOUNDATION Fieldbus H1 and PROFIBUS PA, IECEx approval, Dust protection, International, Europe, USA, Device coupler location: Zone 2 - high-power trunk Zone 1 - high-power trunk Division 2 - high-power trunk Division 1 - high-power trunkpa
Fieldbus Surge Protector, Field Installation on Spur
Pluggable, mounts between device coupler and spur cable, Intrinsically safe (Ex ia), FISCO, Entity, DART Fieldbus, or general-purpose, Optional diagnostics for wear, Grounding of shield via gas-discharge tube, For FOUNDATION Fieldbus H1 and PROFIBUS PA, IECEx approval, Europe, USA, Canada, Device coupler location: non-explosion hazardous area Zone 2 - high-power trunk Zone 1 - high-power trunk Division 2 - high-power trunk Division 1 - high-power trunkpa
Fieldbus Surge Protector, Field Installation on Trunk
Pluggable, mounts between device coupler and trunk cable, Intrinsically safe (Ex ia), FISCO, Entity, DART Fieldbus, or general-purpose, Optional diagnostics for wear, Grounding of shield via gas-discharge tube, For FOUNDATION Fieldbus H1 and PROFIBUS PA, IECEx approval, Europe, USA, Canada, Device coupler location: non-explosion hazardous area Zone 2 - high-power trunk Zone 1 - high-power trunk Division 2 - high-power trunk Division 1 - high-power trunkpa
Fieldbus Surge Protector, Trunk Installation on Power Hub
Pluggable, mounts between Power Hub and trunk cable, Intrinsically safe (Ex ia), FISCO, Entity, DART Fieldbus, or general-purpose, Optional diagnostics for wear, Grounding of shield direct, For FOUNDATION Fieldbus H1 and PROFIBUS PA, IECEx approval, Europe, USA, Canada, Device coupler location: non-explosion hazardous area Zone 2 - high-power trunk Zone 1 - high-power trunk Division 2 - high-power trunk Division 1 - high-power trunk, Device coupler location [2]: Zone 2 - high-power trunkpa
暂不可售: Comprehensive diagnostics for the fieldbus physical layer, Mobile kit for the fieldbus professional, Precise measurements through passive circuits, For commissioning and troubleshooting, For FOUNDATION Fieldbus H1 and PROFIBUS PA, Europe, Device coupler location: non-explosion hazardous area Zone 2 - high-power trunk Division 2 - high-power trunk Division 1 - high-power trunk, Device coupler location [2]: Zone 2 - high-power trunk, Device coupler location [4]: Division 2 - high-power trunkpa
暂不可售: Software user interface for Advanced Diagnostic Modules, Access to mobile ADM via USB-port, Embedded expert system gives pointed advice in clear text, Includes Commissioning Wizard, data historian, oscilloscope..., For FOUNDATION Fieldbus H1 and PROFIBUS PApa
暂不可售: System integration kit for Advanced Diagnostics, PCS integration via Ethernet, Simple automatic setup of Advanced Diagnostics, Common alarm handling, For FOUNDATION Fieldbus and PROFIBUS PApa
暂不可售: Evaluation device for safety thru-beam sensors SLA12 and SLA29, Self-monitoring (type 4 according to IEC/EN 61496-1), Operating mode can be selected by means of DIP switches, Start/Restart disable , Relay monitor, Operating reserve indication, Clearly visible LED functional display, 7-segment diagnostic display, Safety Integrity Level (SIL): SIL 3, Performance level (PL): PL e, Category: Cat. 4, Operating voltage: 24 V DC, -15 %/+20 %fa
暂不可售: ATEX-approval for zone 2 and zone 22, Beam spacing 500 mm, Self-monitoring (type 4 according to IEC/EN 61496-1), Safety outputs OSSD, external status displays OSSD, Start/Restart disable , 7-segment diagnostic display, Operating reserve indication, Degree of protection IP66, Operating mode: can be selected with or without start/restart disable, Safety Integrity Level (SIL): SIL 3, Performance level (PL): PL e, Safety output: 2 separated fail safe semiconductor outputsfa
暂不可售: ATEX-approval for zone 2 and zone 22, Sensing range up to 20 m, Beam spacing 400 mm, Self-monitoring (type 4 according to IEC/EN 61496-1), Safety outputs OSSD, external status displays OSSD, Start/Restart disable , 7-segment diagnostic display, Operating reserve indication, Operating mode: can be selected with or without start/restart disable, Safety Integrity Level (SIL): SIL 3, Performance level (PL): PL e, Safety output: 2 separated fail safe semiconductor outputsfa
暂不可售: ATEX-approval for zone 2 and zone 22, Sensing range up to 20 m, Beam spacing 300 mm, Self-monitoring (type 4 according to IEC/EN 61496-1), Safety outputs OSSD, external status displays OSSD, Start/Restart disable , 7-segment diagnostic display, Operating reserve indication, Operating mode: can be selected with or without start/restart disable, Safety Integrity Level (SIL): SIL 3, Performance level (PL): PL e, Safety output: 2 separated fail safe semiconductor outputsfa
暂不可售: Self-monitoring (type 4 according to IEC/EN 61496-1), Evaluation device for safety thru-beam sensors SLA, for safety light grids SLP and for 2 channel safety devices (emergency off), Operating mode can be selected by means of DIP switches, Start/Restart disable , Relay monitor, Operating reserve indication, Clearly visible LED functional display, 7-segment diagnostic display, Safety Integrity Level (SIL): SIL 3, Performance level (PL): PL e, Category: Cat. 4, Operating voltage: 115 V AC +10/-15 %fa
暂不可售: Self-monitoring (type 4 according to IEC/EN 61496-1), Evaluation device for safety thru-beam sensors SLA, for safety light grids SLP and for 2 channel safety devices (emergency off), Operating mode can be selected by means of DIP switches, Start/Restart disable , Relay monitor, Operating reserve indication, Clearly visible LED functional display, 7-segment diagnostic display, Safety Integrity Level (SIL): SIL 3, Performance level (PL): PL e, Category: Cat. 4, Operating voltage: 115 V AC +10/-15 %fa
暂不可售: Self-monitoring (type 4 according to IEC/EN 61496-1), Evaluation device for safety thru-beam sensors SLA, for safety light grids SLP and for 2 channel safety devices (emergency off), Operating mode can be selected by means of DIP switches, Start/Restart disable , Relay monitor, Operating reserve indication, Clearly visible LED functional display, 7-segment diagnostic display, Safety Integrity Level (SIL): SIL 3, Performance level (PL): PL e, Category: Cat. 4, Operating voltage: 115 V AC +10/-15 %fa