请注意:所有以Pepperl + Fuchs GmbH或Pepperl + Fuchs AG名义发行的产品相关文件,例如证书,合格声明等,同样适用于Pepperl + Fuchs SE。
下载PDF版完整参数表:
产品阐述 |
---|
Div. 2 / Zone 2 Ex-rated barrier |
Supply | ||
---|---|---|
Rated voltage | 9 ... 30 VDC (Um = 30 V SELV) | |
Input current | 120 mA nominal 500 mA max |
|
Indicators/operating means | ||
LED ON | power - keyboard power - Mouse |
|
Interface | ||
Interface type | USB 1.1 or PS2 | |
Output | ||
Output current | 89 mA | |
Output voltage | 4.8 VDC | |
Directive conformity | ||
Electromagnetic compatibility | ||
Directive 2014/30/EU | EN 61326-1:2013 (industrial locations) #224258 | |
RoHS | ||
Directive 2011/65/EU (RoHS) | EN 50581:2012-09 | |
Conformity | ||
Degree of protection | IEC 60529 | |
Protection against electrical shock | IEC 61140 | |
Ambient conditions | ||
Ambient temperature | -40 ... 60 °C (-40 ... 140 °F) | |
Relative humidity | 0 ... 95% (noncondensing) | |
Vibration resistance | 5 G, 58 ... 150 Hz | |
Impact resistance | 15 g, 11 ms | |
Mechanical specifications | ||
Connection type | Terminal Block | |
Degree of protection | IP20 | |
Connection | Supply: terminals 13+, 14- Input: terminals 9+, 10-; 11+, 12- Output: terminals 1+, 2+, 3-, 4-; 5+, 6+, 7-, 8- (field terminal) Ground: terminals 15, 16 |
|
Mass | 120 g | |
Dimensions | 99 mm x 85 mm x 22.5 mm | |
Cable length | Max. 4.6 m (15'): barrier to keyboard/mouse Max. 4.6 m (15'): host pc to keyboard/mouse Max. 6.1 m (20'): total length, host PC to keyboard/mouse |
|
Data for application in connection with hazardous areas | ||
EU-type examination certificate | DEMKO 14ATEX1269806X | |
Marking | II 3 G Ex nA [ic] IIC T6 Gc II 3 G Ex nA [ic IIIB] IIC T6 Gc |
|
Directive conformity | ||
Directive 2014/34/EU | EN 60079-0:2012+A11:2013 , EN 60079-11:2012 , EN 60079-15:2010 | |
International approvals | ||
UL approval | cULus (E106378) | |
Control drawing | 116-0337 | |
Approved for | Mountable in Class I, Division 2, Groups A, B, C, D Providing non-incendive field wiring at field terminals to Class I, Division 2, Groups A, B, C, D Class II, Division 2, Groups F, G Class III, Division 2 Temperature Class T6 Mountable in Class I, Zone 2 Providing intrinsic safety wiring at field terminals for Class I, Zone 2, Group IIC and Group IIIB hazardous locations USL: Class I, Zone 2 AEx nA [ic] IIC T6 Gc Class I, Zone 2 AEx nA [ic IIIB] IIC T6 Gc CNL: Class I, Zone 2, Ex nA [ic] IIC T6 Gc X Class I, Zone 2, Ex nA [ic IIIB] IIC T6 Gc X |
|
IECEx approval | IECEx UL 14.0017X | |
Approved for | Ex nA [ic] IIC T6 Gc Ex nA [ic IIIB] IIC T6 Gc |
|
Standards | IEC 60079-0:2011 (6th edition) IEC 60079-11:2011 (6th edition) IEC 60079-15:2010 (4th edition) |
System | Classcode |
---|---|
ECLASS 13.0 | 19200301 |
ECLASS 12.0 | 19200301 |
ECLASS 11.0 | 19200301 |
ECLASS 10.0.1 | 19200301 |
ECLASS 9.0 | 19200301 |
ECLASS 8.0 | 19200301 |
ECLASS 5.1 | 27242392 |
ETIM 9.0 | EC001692 |
ETIM 8.0 | EC001692 |
ETIM 7.0 | EC001692 |
ETIM 6.0 | EC001692 |
ETIM 5.0 | EC001692 |
UNSPSC 12.1 | 43211706 |
Product category / 产品类的 | 隔离式安全栅 |
Safety and Security Documentation | 语言 | 文件类型 | 文件大小 |
---|---|---|---|
Instruction manual | ENG | 228 KB | |
Manuals | |||
Manual | ENG | 1811 KB |
CAD | 语言 | 文件类型 | 文件大小 |
---|---|---|---|
CAD 2-D DWG / CAD 2-D DWG | ALL | DWG | 387 KB |
CAD 3-D / CAD 3-D | ALL | STP | 1403 KB |
CAD Portal / CAD Portal | ALL | LINK | --- |
Certificates | 证书号码 | 语言 | 文件类型 | 文件大小 |
---|---|---|---|---|
ATEX Certificate | DEMKO 14 ATEX 1269806X | ALL | 522 KB | |
Canada UL cUL | E106378 cUL (QUZW7) | ALL | LINK | --- |
IECEx Certificate of Conformity | IECEx UL 14.0017X | ALL | LINK | --- |
UL Hazardous Location | E106378 (QUZW, QUZW7, QVAG, QVAG7) | ALL | 584 KB | |
USA UL | E106378 UL (QUZW) | ALL | LINK | --- |
Control Drawings | ||||
Control drawing UL / Control drawing UL | ALL | 91 KB | ||
Declaration of Conformity | ||||
EU Declaration of Conformity (P+F) / EU-Konformitäterklärung (P+F) | DOC-B055C | ALL | 47 KB |