Retroreflective sensor without polarization filter, plastic housing, 5 m detection range, infrared light, sensitivity adjuster, light/dark on, DC version, NPN output, fixed cable, User-friendliest photoelectric sensor series for standard applications, Miniature design, Not sensitive to ambient light, Metal-reinforced fastening holes, Version with infrared lightfa
Retroreflective sensor without polarization filter, plastic housing, 5 m detection range, infrared light, sensitivity adjuster, light/dark on, DC version, PNP output, fixed cable, User-friendliest photoelectric sensor series for standard applications, Miniature design, Not sensitive to ambient light, Metal-reinforced fastening holes, Version with infrared lightfa
Retroreflective sensor without polarization filter, plastic housing, 5 m detection range, infrared light, sensitivity adjuster, light/dark on, DC version, NPN output, fixed cable, User-friendliest photoelectric sensor series for standard applications, Miniature design, Not sensitive to ambient light, Metal-reinforced fastening holes, Version with infrared lightfa
Retroreflective sensor without polarization filter, plastic housing, 5 m detection range, infrared light, sensitivity adjuster, light/dark on, DC version, PNP output, M8 plug, User-friendliest photoelectric sensor series for standard applications, Miniature design, Not sensitive to ambient light, Metal-reinforced fastening holes, Version with infrared lightfa
Retroreflective sensor without polarization filter, plastic housing, 5 m detection range, infrared light, sensitivity adjuster, light/dark on, DC version, NPN output, M8 plug, User-friendliest photoelectric sensor series for standard applications, Miniature design, Not sensitive to ambient light, Metal-reinforced fastening holes, Version with infrared lightfa
Pepperl+Fuchs is expanding its comprehensive portfolio of identification solutions with the introduction of the IUT-F190-B40 UHF RFID read/write device, which offers an integrated industrial Ethernet ... temperature range make it suitable for use even in especially challenging industrial environments. Based on UHF RFID technology , this solution achieves high ranges (up to 6 m) and detection speeds and supports multi-tag reading . The built-in, automatically ...
Large portfolio of SIL components for hazardous area applications with functional saftey requirements ... different organizations to ensure an objective assessment. 6. Voluntary External Assessments Many devices, for which an in-house assessment would actually suffice, we have ested by an external assessment. 7. Conservative Product Assessment We actually base ...
Pepperl+Fuchs' VisuNet FLX line offers you the freedom and flexibility to customize an HMI solution that exactly fits your needs-whether you are looking for a full HMI system, panel PC, thin client or ... 6 (based on Microsoft® Windows® 10 IoT Enterprise 2021 LTSC (x64)) Peripherals EXTA4 keyboard for usage in ATEX/IECEx Zone 2/22 115/230 V AC Power Supply [triple certified] HMI Solutions Worldwide Solution Competence At market launch, we already ...
Explore the Pepperl+Fuchs knowledge base to learn more about the installation conditions of inductive sensors ... ] with nonflush mount Extended operating distance [mm] 6.5 1.5 2 - 8 1.5 2 3 12 2 4 6 18 5 8 12 30 10 15 22 Nonflush-Mountable Inductive Sensors Nonflush-mountable inductive sensors achieve the largest possible operating distance in relation to their ...
... to withstand mechanical vibrations. Vibration resistance is tested at a resonance frequency between 10 Hz ... 55 Hz and 1 mm amplitude. cf. IEC 60068-2-6 Voltage drop (U d ) A potential difference that occurs when current passes through a resistor ...
Explore the Pepperl+Fuchs knowledge base to learn more about the power source of two-wire sensors ... - und Regeltechnik der chemischen Industrie", in short: NAMUR). These are two-wire sensors according to EN 60947-5-6 (VDE 0660, part 212) that have a continuous or a noncontinuous distance/current characteristic. Area 0: unactuated area Red area between ...
Purge and pressurization is the most flexible Ex protection method, because it allows the use of non-Ex electrical equipment in hazardous areas Get to know how our Bebco EPS® purge+pressurization sys ... will be 8 (sq ft) x 0.0725 (lbs/sq in) x 144 (sq in/sq ft) = 83 pounds. The purge time = 4 volume exchanges x 22.5 sq.ft. / 12 scfm = 7.5 min. Sometimes larger enclosures can be reinforced for the higher pressure . 6. What Are the Requirements ...
Erfahren Sie mehr zu den Haftungshinweisen zur Nutzung der Pepperl+Fuchs Website ... on a Company’s Website does not imply that such product or service is or will be available in your location. 6. Links to third party Websites If you choose to leave this Website via links to other non-Pepperl+Fuchs Group websites, the Company is not ...
With their flexibility and modularity, the VOS 2-D universal vision sensors offer the perfect solution for your vision application Learn more about the components and software of the VOS sensor serie ... +Fuchs offers matching precision lenses for the C-mount variants of the VOS series. Due to the different focal lengths of 6 mm for short distances with a large field of view and up to 50 mm for further distances and a small field of view, the maximum ...
51-59/59Punkter pr side:
Gav din søgning ingen resultater?
Tip: Sæt * før ordet, ændre søgeordet, kontroller for stavefejl eller kontakt os .