Inductive ring sensor RC10-14-N3-Y115614

RC10-14-N3-Y115614
  • 10 mm inside diameter
  • Comfort series
  • Bistable
  • Direction detection

Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.

Uddrag af datablad: Tekniske data for   RC10-14-N3-Y115614

General specifications
Switching functionNormally closed (NC)
Output typeNAMUR, bistable
Inside diameter10 mm
Measuring cylinder
Diameter1/8" (3.175mm)
Measuring coneCarboloy
Output type2-wire
Nominal ratings
Nominal voltage8.2 V (Ri approx. 1 kΩ)
Operating voltage5 ... 25 V
Hysteresistyp. 1 %
Reverse polarity protectionreverse polarity protected
Current consumption
Traverse B3 mA
Passage B UB=8V≥ 3 mA
Passage B UB=10V≥ 4.2 mA
Traverse A1 mA
Passage A UB=10V0.5 ... 1 mA typ. 0.9 mA
Passage A UB=8V0.5 ... 0.95 mA typ. 0.8 mA
Time delay before availability≤ 5 ms
Functional safety related parameters
MTTFd2140 a
Mission Time (TM)20 a
Diagnostic Coverage (DC)0 %
Compliance with standards and directives
Standard conformity
NAMUREN 60947-5-6:2000
IEC 60947-5-6:1999
StandardsEN IEC 60947-5-2
Approvals and certificates
ATEX approval
Equipment protection level GbPTB 99 ATEX 2128 X
UL approvalcULus Listed, General Purpose
Ambient conditions
Ambient temperature0 ... 40 °C (32 ... 104 °F)
Mechanical specifications
Connection typecable PVC , 5 m
Core cross section0.14 mm2
Housing materialPBT
Degree of protectionIP67
Dimensions
Height32 mm
Width26 mm
Length30 mm
General information
Use in the hazardous areasee instruction manuals

Classifications

SystemClasscode
ECLASS 13.027274001
ECLASS 12.027274001
ECLASS 11.027270101
ECLASS 10.0.127270101
ECLASS 9.027270101
ECLASS 8.027270101
ECLASS 5.127270101
ETIM 9.0EC002714
ETIM 8.0EC002714
ETIM 7.0EC002714
ETIM 6.0EC002714
ETIM 5.0EC002714
UNSPSC 12.139121550

Details: RC10-14-N3-Y115614

Datasheet: RC10-14-N3-Y115614

DatasheetFil typeFil størrelse
数据表 RC10-14-N3-Y115614PDF239 KB

Documents: RC10-14-N3-Y115614

Instruction manualsFil typeFil størrelse
ИнструкцииPDF173 KB
Návod k poużitíPDF167 KB
Instruktions manualPDF166 KB
Instruction manualPDF166 KB
KasutusjuhendPDF162 KB
KäyttöohjePDF161 KB
Manuel d'instructionsPDF168 KB
BetriebsanleitungPDF168 KB
Οδηγίες χρήσηςPDF175 KB
HandleidingPDF166 KB
Instruction manual / BetriebsanleitungPDF166 KB
Használati útmutatóPDF168 KB
Manuale di istruzioniPDF167 KB
Lietošanas pamācībaPDF166 KB
Instrukciju vadovasPDF168 KB
Instrukcja obsługiPDF168 KB
Manual de instruçõesPDF169 KB
Manual de utilizarePDF168 KB
Návod na poużitiePDF168 KB
Navodila za uporaboPDF165 KB
Manual de instruccionesPDF168 KB
ManualPDF165 KB

CAD+CAE: RC10-14-N3-Y115614

CADFil typeFil størrelse
CAD 3-D / CAD 3-DSTP224 KB
CAD Portal / CAD PortalLINK---
EPLAN
CAE EPLAN Data Portal / CAE EPLAN Data PortalLINK---
EPLAN macro EDZ / EPLAN Makro EDZEDZ63 KB

Approvals+Certificates: RC10-14-N3-Y115614

CertificatesFil typeFil størrelse
Canada USA CSA Ordinary LocationPDF99 KB
Canada USA UL Ordinary LocationPDF1806 KB
EU PTB ATEX ia 2GPDF4833 KB
United Kingdom CML UKEX Category II 2 GPDF186 KB
Control Drawings
Control drawing FM / Control drawing FMPDF686 KB
Declaration of Conformity
EU Declaration of Conformity (P+F) / EU-Konformitäterklärung (P+F)PDF1245 KB
UK Declaration of Conformity (P+F)PDF1237 KB

Our amplify article gives interesting insights about the development of the new, modern portfolio of inductive proximity sensors from Pepperl+Fuchs. Get the whole story here! 

 

 

Knowledge Base for Inductive Sensors

The knowledge base for inductive sensors contains extensive expertise and supports you in the highly precise and smooth operation of the sensors in your machinery and plants.

VariKont with Active Shielding Technology

The VariKont inductive sensors with Active Shielding Technology ensure high switching distances, no matter the installation situation and the surrounding material. Benefit from easier equipment design and reduced costs!

Inductive Safety Sensors SIL 2 PL d

As the SIL 2/PL d inductive safety sensors have no dead band, data transfer can occur with no minimum distance between sensor and target. Discover the optimized portfolio for demanding environments.