Hent hele databladet som PDF:
Uddrag af datablad: Tekniske data for
MFT-2L.1600
Produkt beskrivelse |
Multifunction terminal, 4-pin, 2 x bridges |
General specifications |
Function | The specific device function can be found in the ordering information section. |
Electrical specifications |
Resistor | 1 x 1 Ω ... 22 MΩ, 0.5 W 2 x 1 Ω ... 22 MΩ, 0.5 W |
Diode | 1 x I max. 1 A 2 x I max. 0.5 A |
Fuse | 0.032 ... 1.5 A 1.5 ... 6.3 A Pre-arcing time/current characteristic: time-lag T |
| Nominal voltage | max. 250 V AC max. 30 V DC |
Relay | |
| Control | 24 V , approx. 5 ... 8.5 mA |
| Contact loading | AC max. 250 V , max. 1 A DC max. 30 V , max. 1 A |
| Contact resistance | 0.1 Ω at 6 V, 1 A |
| Switching operations NO contact | 3 x 104 |
| Switching operations NC contact | 1 x 104 |
Directive conformity |
Electromagnetic compatibility | |
| Directive 2014/30/EU | EN 61326-1:2013 (industrial locations) |
Conformity |
Degree of protection | IEC 60529:2001 |
Ambient conditions |
Ambient temperature | -55 ... 70 °C (-67 ... 158 °F)
|
Mechanical specifications |
Core cross section | 0.5 ... 2.5 mm2 |
Degree of protection | IP20 , IP30 when plug-in module is plugged in |
Mass | approx. 115 g , depending on model |
Dimensions | 93 x 17.5 x 79 mm (l x w x h) |
Tightening torque | 0.5 ... 1 Nm |
Data for application in connection with hazardous areas |
EU-type examination certificate | PTB 07 ATEX 1004 U |
| Marking | II 2 G Ex d e IIC |
Directive conformity | |
| Directive 2014/34/EU | EN IEC 60079-0:2018+AC:2020 , EN 60079-1:2014 , EN 60079-7:2015+A1:2018 |
International approvals |
IECEx approval | |
| IECEx certificate | IECEx BKI 08.0008U |
| IECEx marking | Ex d e IIC Gb |
Marine approval | |
| DNV GL Marine | TAA0000034 |
General information |
Ordering information | Customer-specific values are available in the E96 series. Minimum order quantity 50 pieces. |
Supplementary information | Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com. |
Classifications
System | Classcode |
ECLASS 13.0 | 27210192 |
ECLASS 12.0 | 27210192 |
ECLASS 11.0 | 27210192 |
ECLASS 10.0.1 | 27210190 |
ECLASS 9.0 | 27210190 |
ECLASS 8.0 | 27210190 |
ECLASS 5.1 | 27242692 |
ETIM 9.0 | EC003015 |
ETIM 8.0 | EC003015 |
ETIM 7.0 | EC003015 |
ETIM 6.0 | EC003015 |
ETIM 5.0 | EC001485 |
UNSPSC 12.1 | 39121008 |
Details:
MFT-2L.1600
Product Documentation:
MFT-2L.1600
Design / Simulation:
MFT-2L.1600
Tilhørende produkter:
MFT-2L.1600
Accessory of |
|
|
|
FieldConnex® FieldBarrier®, 8 ... 12 outputs Ex ia IIC, FISCO and Entity, Advanced fault isolation and diagnostics at the spur, FieldBarrier in Zone 1/Div. 2, Instruments in Zone 0...1/Div. 1, For FOUNDATION Fieldbus H1 and PROFIBUS PA, IECEx approval, Dust protection, International, Europe, USA, Device coupler location: Zone 2 - high-power trunk Zone 1 - high-power trunk Division 2 - high-power trunk Division 1 - high-power trunkpa |
|
Accessories |
|
|
|
pa |
|
Specifications |
|
-
MFT-*
-
Multifunction Terminal
-
|
|
Suitable for fusing solenoids, alarm indicators, sounders etc, and diode decoupling of power supplies, Simple OR gate for zone 1 mounting, visible separation for field devices, relay switches , Bus termination, Current limiting, DIN rail mounting, Maintenance without hot work permit, Wires can be disconnected during operation once the module has been removed (parts under voltage remain covered)pa |
|