Support Industrielle sensorer
Support Explosion Protection

Multifunction Terminal MFT-*

MFT-*
  • Suitable for fusing solenoids, alarm indicators, sounders etc, and diode decoupling of power supplies
  • Simple OR gate for zone 1 mounting, visible separation for field devices, relay switches
  • Bus termination
  • Current limiting
  • DIN rail mounting
  • Maintenance without hot work permit
  • Wires can be disconnected during operation once the module has been removed
    (parts under voltage remain covered)

Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.

Uddrag af datablad: Tekniske data for   MFT-*

Produkt beskrivelse
Multifunction terminal, allows maintenance work to be carried out in hazardous areas without a hot work permit
General specifications
FunctionThe specific device function can be found in the ordering information section.
Electrical specifications
Resistor1 x 1 Ω ... 22 MΩ, 0.5 W
2 x 1 Ω ... 22 MΩ, 0.5 W
Diode1 x I max. 1 A
2 x I max. 0.5 A
Fuse0.032 ... 1.5 A
1.5 ... 6.3 A
Pre-arcing time/current characteristic: time-lag T
Nominal voltagemax. 250 V AC max. 30 V DC
Relay
Control24 V , approx. 5 ... 8.5 mA
Contact loadingAC max. 250 V , max. 1 A
DC max. 30 V , max. 1 A
Contact resistance0.1 Ω at 6 V, 1 A
Switching operations NO contact3 x 104
Switching operations NC contact1 x 104
Directive conformity
Electromagnetic compatibility
Directive 2014/30/EUEN 61326-1:2013 (industrial locations)
Conformity
Degree of protectionIEC 60529:2001
Ambient conditions
Ambient temperature-55 ... 55 °C (-67 ... 131 °F) (Im = 1.5 ... 6.3 A)
-55 ... 70 °C (-67 ... 158 °F) (Im = 0.032 ... 1.5 A)
The specific ambient temperature can be found in the ordering information section.
Mechanical specifications
Core cross section0.5 ... 2.5 mm2
Degree of protectionIP20 , IP30 when plug-in module is plugged in
Massapprox. 115 g , depending on model
Dimensions93 x 17.5 x 79 mm (l x w x h)
Height79 mm
Width17.5 mm
Length93 mm
Tightening torque0.5 ... 1 Nm
Data for application in connection with hazardous areas
EU-type examination certificatePTB 07 ATEX 1004 U
MarkingEx-Hexagon II 2 G Ex d e IIC
Directive conformity
Directive 2014/34/EUEN IEC 60079-0:2018+AC:2020 , EN 60079-1:2014 , EN 60079-7:2015+A1:2018
International approvals
IECEx approval
IECEx certificateIECEx BKI 08.0008U
IECEx markingEx d e IIC Gb
Marine approval
DNV GL MarineTAA0000034
General information
Ordering informationCustomer-specific values are available in the E96 series.
Minimum order quantity 50 pieces.
Supplementary informationObserve the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com.

Classifications

SystemClasscode
ECLASS 13.027210192
ECLASS 12.027210192
ECLASS 11.027210192
ECLASS 10.0.127210190
ECLASS 9.027210190
ECLASS 8.027210190
ECLASS 5.127242692
ETIM 9.0EC003015
ETIM 8.0EC003015
ETIM 7.0EC003015
ETIM 6.0EC003015
ETIM 5.0EC001485
UNSPSC 12.139121008

Details: MFT-*

Datasheet: MFT-*

DatasheetFil typeFil størrelse
Datasheet MFT-*PDF639 KB
Fiche de données MFT-*PDF581 KB
Datenblatt MFT-*PDF641 KB
Datasheet MFT-*PDF585 KB
Hoja de datos MFT-*PDF580 KB

Documents: MFT-*

ManualsFil typeFil størrelse
ManualPDF2766 KB
HandbuchPDF2776 KB
Instruction manuals
ИнструкцииPDF168 KB
Instruction manual / BetriebsanleitungPDF329 KB
Návod k poużitíPDF164 KB
Instruktions manualPDF162 KB
Instruction manualPDF166 KB
KasutusjuhendPDF158 KB
KäyttöohjePDF159 KB
Manuel d'instructionsPDF165 KB
BetriebsanleitungPDF169 KB
Οδηγίες χρήσηςPDF171 KB
HandleidingPDF165 KB
Instruction manual / BetriebsanleitungPDF163 KB
Használati útmutatóPDF163 KB
Manuale di istruzioniPDF162 KB
Lietošanas pamācībaPDF161 KB
Instrukciju vadovasPDF163 KB
Instrukcja obsługiPDF165 KB
Manual de instruçõesPDF164 KB
Manual de utilizarePDF163 KB
Návod na poużitiePDF163 KB
Navodila za uporaboPDF160 KB
Manual de instruccionesPDF165 KB
ManualPDF160 KB
Documents
Functional Safety ManualPDF1993 KB
Handbuch funktionale SicherheitPDF2005 KB

CAD+CAE: MFT-*

CADFil typeFil størrelse
CAD 3-D / CAD 3-DSTP2318 KB
EPLAN
EPLAN macros MFT / EPLAN-Makros MFTZIP11723 KB

Approvals+Certificates: MFT-*

CertificatesFil typeFil størrelse
BKI IECEx Certificate of ConformityLINK---
Brasil TUV Rheinland BrazilPDF1220 KB
Bureau Veritas (Maritime) MarinePDF590 KB
DNV MarinePDF110 KB
Europe PTB ATEX Category 2 GPDF1206 KB
Declaration of Conformity
EU Declaration of Conformity (P+F) / EU-Konformitäterklärung (P+F)PDF358 KB

Tilhørende produkter: MFT-*

Variants
Suitable for fusing solenoids, alarm indicators, sounders etc, and diode decoupling of power supplies, Simple OR gate for zone 1 mounting, visible separation for field devices, relay switches , Bus termination, Current limiting, DIN rail mounting, Maintenance without hot work permit, Wires can be disconnected during operation once the module has been removed
(parts under voltage remain covered)pa
Matching System Components
FieldBarrier Junction Box, Brushed Stainless Steel, 8, 10, 12 outputs Ex ia, Brushed enclosure, IP66, Configurable cable entries for trunk and spurs, Packaged certified solution, For FOUNDATION Fieldbus H1 and PROFIBUS PA, Device coupler location: Zone 2 - high-power trunk
Zone 1 - high-power trunk, Device coupler location [2]: Zone 1 - high-power trunk, Instrument location / spur protection: Zone 0 ... 1 - intrinsic safety, Function: Device coupler, Design / Mounting: Outside installationpa
Accessories

pa