Select Your Country
ICA-16DIO-G60AL-IO I/O Hub
I/O hub with IO-Link interface for 16 digital inputs/outputs
Key Benefits at a Glance
- Sturdy metallic housing
- IO-link interface for service and process data
- 16 digital inputs/outputs can be configured
- Logic level can be configured per port
- Filter time can be configured per port
- Pulse extension can be configured per port
Show more
Preferred Type

















Note
All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.
EN
- EN
- DE
- FR
Technical data of ICA-16DIO-G60AL-IO
| UL File Number | E223772 |
| MTTFd | 2111 a |
| LED UAUX | Green: Actuator supply voltage OK Red: Actuator supply voltage < 18 V | |
| LED IO-Link | Green: module is switched on, no communication Flashing green: communication OK Red: signal line overload | |
| LED A | Orange: status indicator channel A Red: peripheral error | |
| LED B | White: status indicator channel B Red: peripheral error | |
| LED US | Green: system/sensor supply voltage OK Red: system/sensor supply voltage < 18 V Flashing red: sensor supply voltage overload |
| Rated operating voltage | Ue | 18 ... 30 V |
| Nominal voltage | 24 V DC | |
| Nominal current | 16 A | |
| Current consumption | typ. 80 mA | |
| Current loading capacity | max. 16 A per module (for UL applications, max. 9 A) |
| Interface type | IO-Link | |
| IO-Link revision | 1.1 | |
| Device profile | Identification and Diagnosis - I&D | |
| Device ID | 0x0F0203 (983555) | |
| Transfer rate | COM3 (230.4 kbits/s) | |
| Min. cycle time | 2 ms | |
| Process data width | Input 4 Byte Output 4 Byte | |
| SIO mode support | no | |
| Compatible master port type | A |
| Number/Type | 16 digital inputs/outputs, configurable Inputs: 2-, 3-, 4-wire PNP, DC, supply from US Outputs: 2-wire PNP, DC, supply from UL No galvanic isolation between US and UL short-circuit protected | |
| Sensor supply | max. 500 mA per port (X1 - X8) | |
| Output current | Ie | max. 2 A per channel (X1 - X8) / 4 A per port max. 9 A per module |
| Electromagnetic compatibility | |||||
| |||||
| Degree of protection | EN 60529:2000 | |
| Fieldbus standard | Type 1 according to IEC 61131-2 | |
| Emitted interference | EN 61000-6-2:2005 | |
| Noise immunity | EN 61000-6-4:2007+A1:2011 | |
| Shock resistance | EN 61131-2:2004 |
| Ambient temperature | -20 ... 70 °C (-4 ... 158 °F) | |
| Storage temperature | -40 ... 70 °C (-40 ... 158 °F) | |
| Relative humidity | max. 95 % | |
| Altitude | 0 ... 2000 m | |
| Shock and impact resistance | 50 g, 11 ms, all axes | |
| Vibration resistance | 15 g / 5 ... 500 Hz | |
| Pollution degree | 3 |
| Degree of protection | IP65 / IP67 / IP69K | |||||||||||||
| Connection | Power Supply M12, L-coded IO-Link M12, A-coded Inputs/Outputs M12, A-coded | |||||||||||||
| Material | ||||||||||||||
| ||||||||||||||
| Mass | 400 g | |||||||||||||
| Dimensions | ||||||||||||||
| ||||||||||||||
| Construction type | Field housing | |||||||||||||
Related Pages