Seleccione su país
ICA-8DIO4M1-G20-IO IO-Link Motor Roller Module
G20 MDR module with IO-Link for 8 digital inputs/outputs and 4 connections for MDRs
Ventajas clave de un vistazo
- Inputs for 2- and 3-wire sensors
- Electronic PNP outputs
- Connections for DC roller motors
- Configuration and control via IO-Link
- Function indicator for motors, inputs and outputs
Mostrar más









Nota
Todos los documentos relacionados con los productos, como certificados, declaraciones de conformidad, etc., que se emitieron antes de la conversión con el nombre de Pepperl+Fuchs GmbH o Pepperl+Fuchs AG también se aplican a Pepperl+Fuchs SE.
EN
- EN
- DE
- FR
- JA
Datos técnicos de ICA-8DIO4M1-G20-IO
| UL File Number | E223772 "For use in NFPA 79 Applications only" | |
| MTBF | 90 a | |
| Compatible roller motors | Interroll EC310 Interroll EC5000 24 V AI (20 W / 35 W / 50 W) Rulmeca BL3 Itoh Denki PM500XK Itoh Denki PM500XC PULSEROLLER Senergy-IDC MTA MRD50 (A interface, 24 V to 40 W) WWL R-*-H + CE23XX Conveline RM50 Mambaroll Built-In Drive Roller 50 UniDrive ONE |
| LED yellow/red | IO1 ... IO8: IO-Link status MOT1 ... MOT4: motor status |
| Auxiliary voltage | UPWR | 18 ... 30 VDC PELV Max. 10 A Current limitation of the supply max. 30 A For UL: Z-type miniature circuit breaker in accordance with UL 1077, max. 20 A, required |
| Operating voltage | UB | 18 ... 30 V DC, PELV Max. 2.5 A (IO-Link) Current limitation of the supply max. 4 A |
| No-load supply current | I0 | ≤ 25 mA |
| Operating current | IB | max. 2.5 A |
| Interface type | IO-Link | |
| IO-Link revision | 1.1 | |
| Device profile | Identification and Diagnosis - I&D | |
| Process data | 8 byte inputs (STD/EXT) 6 byte outputs (STD) 18 byte outputs (EXT) | |
| Vendor ID | 1 (0x0001) | |
| Device ID | Rev. A: 984066 (0x0F0402) (STD) - default 984065 (0x0F0401) (EXT) Rev. B: 984066 (0x0F0402) (STD) 984065 (0x0F0401) (EXT) 984070 (0x0F0406) (STD) - default 984069 (0x0F0405) (EXT) | |
| Data transfer rate | COM3 (230.4 kbits/s) | |
| Min. cycle time | 1.2 ms (STD) 2 ms (EXT) | |
| SIO mode support | no | |
| Compatible master port type | Class A |
| Number/Type | 8 Inputs for 3-wire sensors (PNP), DC (IO1 ... IO8) | |
| Supply | from IO-Link | |
| Current loading capacity | 200 mA , overload and short-circuit protected | |
| Input current | ≤ 5 mA (limited internally) | |
| Switching point | Type 3 according to IEC 61131-2 |
| Number/Type | 8 electronic outputs, PNP (IO1 … IO8), overload proof and short-circuit proof | |
| Supply | from IO-Link | |
| Current | 200 mA per output | |
| Voltage | ≥ (Ue - 1.5 V) |
| Number/Type | 4 outputs for DC roller motors (MOT1 ... MOT4) | |
| Supply | via UPWR | |
| Current loading capacity | 3.5 A (continuous), 5 A (< 2 s), max. 7.5 A (< 0.3 s) per motor Total current (continuous) max. 10 A per device | |
| Overload protection | Fuse 5 A, I2t = 53.7 A2s per motor | |
| Signal level | Speed: US = 0.3 … 10 V in no-load operation Ri = 5.6 kΩ, RLOAD ≥ 35 kΩ Direction of rotation: Digital output PNP UD low = high resistance UD high ≥ (UPWR -0.5 V) Current-carrying capacity 400 mA, overload proof and short-circuit proof | |
| Fault level | Motor fault: Digital input NPN 0 (no error) ≥ 125 µA 1 (error) ≤ 25 µA |
| Number/Type | 4 electronic outputs, PNP (DIR/OUT1 … DIR/OUT4), overload and short-circuit proof | |
| Supply | via UPWR | |
| Current | 400 mA per output | |
| Voltage | ≥ (UPWR - 0.5 V) |
| Electromagnetic compatibility | |||||
| |||||
| Degree of protection | EN 60529:2000 | |
| Input | EN 61131-2:2007 | |
| Communication interface | IEC 61131-9 / IO-Link V1.1.2 | |
| Emitted interference | EN 61000-6-4:2007 | |
| Noise immunity | EN 61000-6-2:2005, EN 61326-1:2006 |
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
| Storage temperature | -25 ... 70 °C (-13 ... 158 °F) | |
| Relative humidity | 85 % non-condensing | |
| Climatic conditions | For indoor use only | |
| Altitude | ≤ 2000 m above MSL | |
| Shock and impact resistance | 30 g, 11 ms in 6 spatial directions, 3 shocks 10 g, 16 ms in 6 spatial directions, 1000 shocks | |
| Vibration resistance | 0.35 mm / 5 g 5 ... 500 Hz | |
| Pollution degree | 2 |
| Degree of protection | IP67 according to EN 60529 | ||||||||||
| Connection | 24 V power (PWR): Piercing technology, black flat cable IO-Link: M12 round plug connector in accordance with EN 61076-2-101, LM type (4-pin, connector contacts, screw-locking, A-coded) Female connector: LF type or similar Inputs/outputs (IO), motors (MOT): M8 round plug connector in accordance with EN 61076-2-104 IO: LF type (4-pin, bushing contacts, screw-locking, A-coded) Female connector: LM type or similar MOT: NF type (5-pin, bushing contacts, snap-locking, B-coded) Female connector: NM type or similar | ||||||||||
| Mass | 310 g | ||||||||||
| Dimensions | |||||||||||
| |||||||||||
| Mounting | 2 clips with ∅ 8 mm drill hole The module must be secured to a solid, continuous surface using the two lugs | ||||||||||
| Cable length | 1 m (IO-Link) 0.5 m (IO1/2, IO5/6), 0.65 m (IO3/4, IO7/8) 0.5 m (MOT1, MOT3); 0.4 m (MOT2, MOT4) max. 10 m | ||||||||||
| Note | The flat cable routing is designed for 100 actuation cycles | ||||||||||