Visite el sitio web global
1-channel, Input Ex ia, Installation in suitable enclosures in Zone 1, Module can be exchanged under voltage (hot swap), Explosion protection: Ex ia, Function: Counter , Function [2]: frequency, Function [3]: direction of rotation, Connection: NAMUR sensor, Connection [2]: volt-free contact
8-channel, Inputs Ex ia, Installation in suitable enclosures in Zone 1, Module can be exchanged under voltage (hot swap), Explosion protection: Ex ia, Connection: NAMUR sensor, Connection [2]: volt-free contact
8-channel, Inputs with plug-in Ex e terminals, Installation in suitable enclosures in Zone 1, Module can be exchanged under voltage (hot swap), Explosion protection: Ex e connection, Connection: NAMUR sensor, Connection [2]: volt-free contact, Connection [3]: active binary signal 24 V DC
1-channel, 1 digital output, 2 digital inputs, Inputs and output Ex ia, Installation in suitable enclosures in Zone 1, Explosion protection: Ex ia, Field device: Solenoid Valve, Field device [2]: audible alarm, Field device [3]: visual alarm
1-channel, Input Ex ia, Installation in suitable enclosures in Zone 1, Module can be exchanged under voltage (hot swap), Explosion protection: Ex ia, Field device: pressure converter, Field device [2]: flow converter, Field device [3]: level converter, Field device [4]: Temperature Converter, Connection: 2-wire transmitter, Connection [2]: 3-wire transmitter, Connection [3]: 4-wire transmitter, HART communication
4-channel, Inputs Ex ia, Installation in suitable enclosures in Zone 1, Module can be exchanged under voltage (hot swap), Explosion protection: Ex ia, Field device: pressure converter, Field device [2]: flow converter, Field device [3]: level converter, Field device [4]: Temperature Converter, Connection: 2-wire transmitter, Connection [2]: 3-wire transmitter, Connection [3]: 4-wire transmitter, HART communication
1-channel, Output Ex ia, Installation in suitable enclosures in Zone 1, Module can be exchanged under voltage (hot swap), Explosion protection: Ex ia, Field device: Proportional Valve, Field device [2]: I/P converters, Field device [3]: on-site display
4-channel, Outputs Ex ia, Installation in suitable enclosures in Zone 1, Module can be exchanged under voltage (hot swap), Explosion protection: Ex ia, Field device: Proportional Valve, Field device [2]: I/P converters, Field device [3]: on-site display
4-channel, Inputs Ex ia, Installation in suitable enclosures in Zone 1, Module can be exchanged under voltage (hot swap), Explosion protection: Ex ia, Field device: resistance thermometer, Field device [2]: slide-wire sensors, Field device [3]: potentiometer, Connection: 2-wire sensor, Connection [2]: 3-wire sensor, Connection [3]: 4-wire sensor
4-channel, Inputs Ex ia, Installation in suitable enclosures in Zone 1, Module can be exchanged under voltage (hot swap), Explosion protection: Ex ia, Field device [2]: Thermocouple, Field device [4]: mV source
2-channel, Outputs Ex ia, Installation in suitable enclosures in Zone 1, Module can be exchanged under voltage (hot swap), Explosion protection: Ex ia, Field device: Solenoid Valve, Field device [2]: audible alarm, Field device [3]: visual alarm
2-channel, Outputs wired to Ex e terminals, Installation in suitable enclosures in Zone 1 or Zone 21, Positive or negative logic selectable
4-channel, Outputs wired to Ex e terminals, Installation in suitable enclosures in Zone 1 or Zone 21, Positive or negative logic selectable
8-channel, Installation in suitable enclosures in Zone 1, Positive or negative logic selectable, Simulation mode for service operations (forcing), Explosion protection: Ex e connection
4-channel, Inputs Ex ia, Outputs Ex ia, Installation in suitable enclosures in Zone 1, Module can be exchanged under voltage (hot swap), Explosion protection: Ex ia, Field device: pressure converter, Field device [2]: flow converter, Field device [3]: level converter, Field device [4]: Temperature Converter, Connection: 2-wire transmitter, HART communication
4-channel, Inputs Ex ia, Outputs Ex ia, Installation in suitable enclosures in Zone 1, Module can be exchanged under voltage (hot swap)
4-channel, Inputs with plug-in Ex e terminals, Installation in suitable enclosures in Zone 1, Module can be exchanged under voltage (hot swap), Explosion protection: Ex e connection, Field device: pressure converter, Field device [2]: flow converter, Field device [3]: level converter, Field device [4]: Temperature Converter, Connection: 2-wire transmitter, HART communication
4-channel, Inputs with plug-in Ex e terminals, Installation in suitable enclosures in Zone 1, Module can be exchanged under voltage (hot swap)
Interface between the I/O modules and the PCS/PLC, Com unit for 80 analog or 184 digital channels, Communication via PROFIBUS DP, Module can be exchanged under voltage (hot swap), Fieldbus type: PROFIBUS DP/DP-V1
Interface between the I/O modules and the PCS/PLC, Com unit for 80 analog or 184 digital channels, Communication via PROFIBUS DP, Installation in suitable enclosures in Zone 1, Fieldbus type: PROFIBUS DP/DP-V1
Interface between the I/O modules and the PCS/PLC, Com unit for 80 analog or 184 digital channels, Communication via MODBUS RTU, Installation in suitable enclosures in Zone 1, Fieldbus type: MODBUS RTU
Interface between the I/O modules and the PCS/PLC, Com unit for 20 analog or 40 digital channels, Communication via FOUNDATION Fieldbus H1, HART communication via service bus, Fieldbus type: FOUNDATION Fieldbus H1
Interface between the I/O modules and the PCS/PLC, Communication via MODBUS TCP, Installation in suitable enclosures in Zone 1, Module can be exchanged under voltage (hot swap), Fieldbus type: MODBUS TCP
Interface between the I/O modules and the PCS/PLC, Com unit for 80 analog or 184 digital channels, Communication via MODBUS TCP, Installation in suitable enclosures in Zone 1, Fieldbus type: MODBUS TCP
Communication via PROFINET, Installation in suitable enclosures in Zone 1, Interface between the I/O modules and the PCS/PLC, Non-volatile memory for configuration and parameter settings, Fieldbus type: PROFINET
Power supply for 100 - 230 V AC, Suitable for the supply of FOL, field products (analyzers, level meters etc.), Installation in suitable enclosures in Zone 1, Module can be exchanged under voltage (hot swap), Voltage: 24 V DC +/- 3% (Connectors 5, 12) , 23 V DC +/- 3% decoupled via diode (Connectors 5, 13)
Power supply for 24 V DC, Installation in suitable enclosures in Zone 1, Module can be exchanged under voltage (hot swap), Voltage: 5.4 V DC +/- 5% , , 12 V DC + 4/- 2%
Preconfigured enclosures for engineered FB systems, Installation in Zone 1 and Zone 21, Installation in Zone 2 and Zone 22, Max. 10 slots for I/O modules, Number of modules: 10, Material: Stainless steel, I/O modules (single width): max. 10, I/O modules (dual width): max. 5, Redundancy: possible
Preconfigured enclosures for engineered FB systems, Installation in Zone 1 and Zone 21, Installation in Zone 2 and Zone 22, Max. 10 slots for I/O modules, Number of modules: 10, Material: Stainless steel, I/O modules (single width): max. 10, I/O modules (dual width): max. 5, Redundancy, Redundancy
Multi range power supply 90 ... 253 V AC, Suitable for the supply of 24 I/O modules and 1 bus coupler, Use two power supplies for redundancy, Installation in suitable enclosures in Zone 1, Voltage: 5.4 V DC +/- 5% , , 12 V DC +/- 3%
Preconfigured enclosures for engineered FB systems, Installation in Zone 1 and Zone 21, Installation in Zone 2 and Zone 22, Max. 20 slots for I/O modules, Number of modules: 20, Material: Stainless steel, I/O modules (single width): max. 20, I/O modules (dual width): max. 10, Redundancy: possible
Preconfigured enclosures for engineered FB systems, Installation in Zone 1 and Zone 21, Installation in Zone 2 and Zone 22, Max. 20 slots for I/O modules, Number of modules: 20, Material: Stainless steel, I/O modules (single width): max. 20, I/O modules (dual width): max. 10, Redundancy, Redundancy
Preconfigured enclosures for engineered FB systems, Installation in Zone 1 and Zone 21, Installation in Zone 2 and Zone 22, Max. 24 slots for I/O modules, Number of modules: 12, Material: Stainless steel, I/O modules (single width): max. 24, I/O modules (dual width): max. 12
Preconfigured enclosures for engineered FB systems, Installation in Zone 1 and Zone 21, Installation in Zone 2 and Zone 22, Max. 40 slots for I/O modules, Number of modules: 40, Material: Stainless steel, I/O modules (single width): max. 40, I/O modules (dual width): max. 20, Redundancy: possible
Preconfigured enclosures for engineered FB systems, Installation in Zone 1 and Zone 21, Installation in Zone 2 and Zone 22, Max. 40 slots for I/O modules, Number of modules: 40, Material: Stainless steel, I/O modules (single width): max. 40, I/O modules (dual width): max. 20, Redundancy, Redundancy
Preconfigured enclosures for engineered FB systems, Installation in Zone 1 and Zone 21, Installation in Zone 2 and Zone 22, Max. 48 slots for I/O modules, Number of modules: 24, Material: Stainless steel, I/O modules (single width): max. 48, I/O modules (dual width): max. 24
Universal backplane, Max. 10 slots for I/O modules, Redundancy (field bus and power supply), Installation in Zone 1
Universal backplane, Max. 20 slots for I/O modules, Redundancy (field bus and power supply), Installation in Zone 1
Base backplane for FB system, Max. 24 slots for I/O modules, Installation in Zone 1, For PROFIBUS, MODBUS RTU or MODBUS TCP
Extension backplane for FB system, Max. 24 slots for I/O modules, Installation in Zone 1, For PROFIBUS, PROFINET, MODBUS RTU or MODBUS TCP
Backplane for FB9205 Power Supply, Slots for 2 power supplies, Powert supplies ca be operated separately or parallel, Redundant supply
49 / 137
¿Busca más información? Puede obtener más información en nuestras páginas relacionadas.
Lea las últimas noticias y aplicaciones sobre los productos seleccionados.