Sélectionnez votre pays
LTC57 Guided Level RadarPulscon
Principaux avantages en un coup d'œil
- Premium device for level measurement in bulk solids
- Measuring range up to 45 m (148 foot)
- Process connection 1-1/2 inch thread or flange
- Temperature range up to 150 °C (302 °F)
- Pressure range up to 16 bar (232 psi)
- Up to SIL 3 acc. to IEC/EN 61508
Afficher plus



Remarque
Tous les documents relatifs aux produits, tels que les certificats, les déclarations de conformité, etc., qui ont été émis avant la conversion sous le nom de Pepperl+Fuchs GmbH ou Pepperl+Fuchs AG, s'appliquent également à Pepperl+Fuchs SE.
EN
- EN
- DE
Données techniques relatives à LTC57
| Measuring method | The device is a measuring system that functions according to the time-of-flight method. The distance from the reference point (process connection of the measuring device) to the product surface is measured. | |
| Construction type | device with rod probe device with rope probe | |
| Series | LTC57 |
| Safety Integrity Level (SIL) | SIL 3 |
| Rated voltage | Ur | 11.5 ... 35 V DC, 2-wire 10.4 ... 48 V DC, 4-wire 90 ... 253 V AC, 50/60 Hz |
| Measured variable | distance between reference point and product surface | |
| Measuring range | rod probe: 4 m (13 ft) rope probe: 45 m (148 ft) |
| Output signal | 4 ... 20 mA 2 x 4 ... 20 mA | |
| Communication | 4 ... 20 mA HART (standard) PROFIBUS PA (option) |
| Electromagnetic compatibility | |||||
| |||||
| Low voltage | |||||
| |||||
| Degree of protection | IEC 60529:2001 |
| Accuracy | digital: - measuring range up to 15 m (49 feet): ±2 mm (0.08 inch) - measuring range > 15 m (49 feet): ±10 mm (0.39 inch) analog: 0.02 % sum of non-linearity, non-repeatability and hysteresis included in the maximum measured error |
| Process conditions | |||||||||||
| |||||||||||
| Ambient temperature | -40 ... 80 °C (-40 ... 176 °F) |
| Degree of protection | IP68, NEMA 6P (24 hours in water 1.83 m (6 ft) deep) IP66, NEMA 4X | |
| Connection | gland M20 thread M20, G1/2, NPT1/2 device plug M12, 7/8 in | |
| Material | materials in contact with process : rod probe: 1.4404/316L rope probe: 1.4401/316 (optional PA coated) process connections: 1.4301/304, 1.4401/316, 1.4404/316L process membran, seal: Viton, EPDM | |
| Dimensions | see technical information (TI) | |
| Process connection | threads: G1-1/2, NPT1-1/2 flanges: DIN EN from DN40, ANSI from 1-1/2", JIS from DN40 |
| EU-type examination certificate | see instruction manuals | ||||
| Directive conformity | |||||
| |||||
| IECEx approval | see instruction manuals |
| Display elements | without display display SD02 4-line , optional | |
| Use | via communicator via pushbuttons |
| Overspill protection | see approval (ZE) | |
| Telecommunications | radio license FCC |
| Supplementary documentation | technical information (TI) manuals, brief instructions (BA, KA) instruction manuals approval (ZE) | |
| Supplementary information | Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com. |
| Designation | see technical information (TI) |