8-channel, Inputs Ex ia, Installation in suitable enclosures in Zone 1, Module can be exchanged under voltage (hot swap), Explosion protection: Ex ia, Connection: NAMUR sensor, Connection [2]: volt-free contact
4-channel, Inputs Ex ia, Installation in suitable enclosures in Zone 1, Module can be exchanged under voltage (hot swap), Explosion protection: Ex ia, Field device: pressure converter, Field device [2]: flow converter, Field device [3]: level converter, Field device [4]: Temperature Converter, Connection: 2-wire transmitter, Connection [2]: 3-wire transmitter, Connection [3]: 4-wire transmitter, HART communication
4-channel, Inputs Ex ia, Installation in suitable enclosures in Zone 1, Module can be exchanged under voltage (hot swap), Explosion protection: Ex ia, Field device: resistance thermometer, Field device [2]: slide-wire sensors, Field device [3]: potentiometer, Connection: 2-wire sensor, Connection [2]: 3-wire sensor, Connection [3]: 4-wire sensor
4-channel, Inputs Ex ia, Outputs Ex ia, Installation in suitable enclosures in Zone 1, Module can be exchanged under voltage (hot swap), Explosion protection: Ex ia, Field device: pressure converter, Field device [2]: flow converter, Field device [3]: level converter, Field device [4]: Temperature Converter, Connection: 2-wire transmitter, HART communication
Interface between the I/O modules and the PCS/PLC, Com unit for 80 analog or 184 digital channels, Communication via PROFIBUS DP, Installation in suitable enclosures in Zone 1, Fieldbus type: PROFIBUS DP/DP-V1
Power supply for 24 V DC, Installation in suitable enclosures in Zone 1, Module can be exchanged under voltage (hot swap), Voltage: 5.4 V DC +/- 5% , , 12 V DC + 4/- 2%
Active termination of the fieldbus and passive termination of the service bus, Installation in suitable enclosures in Zone 1, Module can be exchanged under voltage in Zone 1 (hot swap; be aware bus operation may be affected)
1-channel, Input Ex ia, Mounting in Zone 2, Class I/Div.2 or in the safe area, Input for frequency, counter, direction of rotation, Explosion protection: Ex ia, Function: Counter , Function [2]: frequency, Function [3]: direction of rotation, Connection: NAMUR sensor, Connection [2]: volt-free contact
8-channel, Inputs Ex ia, Mounting in Zone 2, Class I/Div.2 or in the safe area, Dry contact or NAMUR inputs, Explosion protection: Ex ia, Connection: NAMUR sensor, Connection [2]: volt-free contact
1-channel, Input Ex ia, Mounting in Zone 2, Class I/Div.2 or in the safe area, Power supply for 2- or 3-wire transmitters with 4 mA ... 20 mA, Explosion protection: Ex ia, Field device: pressure converter, Field device [2]: flow converter, Field device [3]: level converter, Field device [4]: Temperature Converter, Connection: 2-wire transmitter, Connection [2]: 3-wire transmitter, Connection [3]: 4-wire transmitter, HART communication
4-channel, Inputs Ex ia, Mounting in Zone 2, Class I/Div.2 or in the safe area, Power supply for 2-wire transmitters with 4 mA ... 20 mA, Explosion protection: Ex ia, Field device: pressure converter, Field device [2]: flow converter, Field device [3]: level converter, Field device [4]: Temperature Converter, Connection: 2-wire transmitter, Connection [2]: 3-wire transmitter, Connection [3]: 4-wire transmitter, HART communication
4 channels, Inputs Ex ia, Mounting in Zone 2, Class I/Div.2 or in the safe area, Converter for 2-, 3- and 4-wire RTDs (Pt100 ... Pt1000), slide wire sensors etc., Explosion protection: Ex ia, Field device: resistance thermometer, Field device [2]: slide-wire sensors, Field device [3]: potentiometer, Connection: 2-wire sensor, Connection [2]: 3-wire sensor, Connection [3]: 4-wire sensor
4 channels, Inputs Ex ia, Mounting in Zone 2, Class I/Div.2 or in the safe area, Converter for thermocouples and mV-signals, Explosion protection: Ex ia, Compensation (reference junction CJC): internal cold junction compensation or external cold junction, Field device [2]: Thermocouple, Field device [4]: mV source, Compensation (reference junction CJC): internal cold junction compensation or external cold junction
2-channel, Outputs Ex ia, Mounting in Zone 2, Class I/Div.2 or in the safe area, Line fault detection switched on and off, Explosion protection: Ex ia
4-channel, Inputs Ex ia, Outputs Ex ia, Analog input, digital input,, analog output, digital output, Mounting in Zone 2, Class I/Div.2 or in the safe area
Interface between the I/O modules and the PCS/PLC, Com unit for 80 analog or 184 digital channels, Communication via PROFIBUS DP, Mounting in Zone 2, Class I/Div.2 or in the safe area, Fieldbus type: PROFIBUS DP/DP-V1
Interface between the I/O modules and the PCS/PLC, Com unit for 80 analog or 184 digital channels, Communication via MODBUS RTU, Mounting in Zone 2, Class I/Div.2 or in the safe area, Fieldbus type: MODBUS RTU
Interface between the I/O modules and the PCS/PLC, Com unit for 80 analog or 184 digital channels, Communication via MODBUS TCP, Mounting in Zone 2, Class I/Div.2 or in the safe area, Fieldbus type: MODBUS TCP
Power supply for 24 V, Permits vertical or horizontal mounting in Zone 2, Use three power supplies for redundancy, Galvanic isolation to mains, Voltage: 5.4 V DC +/- 5% , , 12 V DC + 4/- 2%
Borne à ressort, Pour boîtiers de raccordement LB et FB, 6 broches, Étiquetage 1…6, Couleur bleue, Pour des applications Ex ia ou Ex ib, Forme constructive: borne à ressort
Borne à ressort, Pour boîtiers de raccordement LB et FB, 8 broches, Étiquetage 1…8, Couleur bleue, Pour des applications Ex ia ou Ex ib, Forme constructive: borne à ressort
Borne à ressort, Pour boîtiers de raccordement LB et FB, 2 x 8 bornes, Étiquetage 1…8 et 9…16, Couleur bleue, Pour des applications Ex ia ou Ex ib, Forme constructive: borne à ressort
Borne à vis frontale, Pour boîtiers de raccordement LB et FB, 6 broches, Étiquetage 1…6, Couleur bleue, Pour des applications Ex ia ou Ex ib, Forme constructive: borne à vis frontale
Borne à vis frontale, Pour boîtiers de raccordement LB et FB, 8 broches, Étiquetage 1…8, Couleur bleue, Pour des applications Ex ia ou Ex ib, Forme constructive: borne à vis frontale
Borne à vis frontale, Pour boîtiers de raccordement LB et FB, 2 x 8 bornes, Étiquetage 1…8 et 9…16, Couleur bleue, Pour des applications Ex ia ou Ex ib, Forme constructive: borne à vis frontale
Borne à ressort, Pour boîtiers de raccordement LB, 8 broches, Couleur bleue, Pour des applications Ex ia ou Ex ib, Pour embouts de câble sans manchon en plastique uniquement, Forme constructive: borne à ressort
1-channel, Input Ex ia, Installation in suitable enclosures in Zone 1, Module can be exchanged under voltage (hot swap), Explosion protection: Ex ia, Function: Counter , Function [2]: frequency, Function [3]: direction of rotation, Connection: NAMUR sensor, Connection [2]: volt-free contact
8-channel, Inputs with plug-in Ex e terminals, Installation in suitable enclosures in Zone 1, Module can be exchanged under voltage (hot swap), Explosion protection: Ex e connection, Connection: NAMUR sensor, Connection [2]: volt-free contact, Connection [3]: active binary signal 24 V DC
1-channel, 1 digital output, 2 digital inputs, Inputs and output Ex ia, Installation in suitable enclosures in Zone 1, Explosion protection: Ex ia, Field device: Solenoid Valve, Field device [2]: audible alarm, Field device [3]: visual alarm
1-channel, Input Ex ia, Installation in suitable enclosures in Zone 1, Module can be exchanged under voltage (hot swap), Explosion protection: Ex ia, Field device: pressure converter, Field device [2]: flow converter, Field device [3]: level converter, Field device [4]: Temperature Converter, Connection: 2-wire transmitter, Connection [2]: 3-wire transmitter, Connection [3]: 4-wire transmitter, HART communication
1-channel, Output Ex ia, Installation in suitable enclosures in Zone 1, Module can be exchanged under voltage (hot swap), Explosion protection: Ex ia, Field device: Proportional Valve, Field device [2]: I/P converters, Field device [3]: on-site display
4-channel, Outputs Ex ia, Installation in suitable enclosures in Zone 1, Module can be exchanged under voltage (hot swap), Explosion protection: Ex ia, Field device: Proportional Valve, Field device [2]: I/P converters, Field device [3]: on-site display
4-channel, Inputs Ex ia, Installation in suitable enclosures in Zone 1, Module can be exchanged under voltage (hot swap), Explosion protection: Ex ia, Field device [2]: Thermocouple, Field device [4]: mV source
2-channel, Outputs Ex ia, Installation in suitable enclosures in Zone 1, Module can be exchanged under voltage (hot swap), Explosion protection: Ex ia, Field device: Solenoid Valve, Field device [2]: audible alarm, Field device [3]: visual alarm
2-channel, Outputs wired to Ex e terminals, Installation in suitable enclosures in Zone 1 or Zone 21, Positive or negative logic selectable
4-channel, Outputs wired to Ex e terminals, Installation in suitable enclosures in Zone 1 or Zone 21, Positive or negative logic selectable
8-channel, Installation in suitable enclosures in Zone 1, Positive or negative logic selectable, Simulation mode for service operations (forcing), Explosion protection: Ex e connection
4-channel, Inputs Ex ia, Outputs Ex ia, Installation in suitable enclosures in Zone 1, Module can be exchanged under voltage (hot swap)
4-channel, Inputs with plug-in Ex e terminals, Installation in suitable enclosures in Zone 1, Module can be exchanged under voltage (hot swap), Explosion protection: Ex e connection, Field device: pressure converter, Field device [2]: flow converter, Field device [3]: level converter, Field device [4]: Temperature Converter, Connection: 2-wire transmitter, HART communication
4-channel, Inputs with plug-in Ex e terminals, Installation in suitable enclosures in Zone 1, Module can be exchanged under voltage (hot swap)
Interface between the I/O modules and the PCS/PLC, Com unit for 80 analog or 184 digital channels, Communication via PROFIBUS DP, Module can be exchanged under voltage (hot swap), Fieldbus type: PROFIBUS DP/DP-V1
Interface between the I/O modules and the PCS/PLC, Com unit for 80 analog or 184 digital channels, Communication via MODBUS RTU, Installation in suitable enclosures in Zone 1, Fieldbus type: MODBUS RTU