Thin Client Firmware for VisuNet Remote Monitors and Box Thin Clients, Innovative firmware to support easy integration and management of remote monitors and thin clients, Supports installation of third-party applications, such as Citrix Receiver and Java Runtime, Based on Microsoft® Windows 10 IoT Enterprise LTSB 2016, Microsoft Universal Write Filter, firewall, USB lock-down, and virus scanner support for maximum system security, Auto connect to host systems after RM startuppa
VisuNet RM Shell 5 2019 LTSC Upgrade-Package for VisuNet Remote Monitors and Box Thin Clients, Upgrade HMI devices from RM Shell 4 or 5 (based on Windows® 10 IoT 2016 LTSB) to RM Shell 5 (based on Windows® 10 IoT 2019 LTSC), Easy download of new images, Contains COA label that licenses the thin client for the new operating systempa
VisuNet RM Shell 6 Upgrade-Package for VisuNet Remote Monitors and Box Thin Clients, Upgrade HMI devices from RM Shell 5 to RM Shell 6 (based on Windows® 10 IoT LTSC 2021), Easy download of new images, Contains COA label that licenses the thin client for the new operating systempa
Significant time savings when replacing worn washer gaskets, Easy installation, Degree of protection IP66 / IP68, Available for various thread sizes, UV resistant, Ozone resistant, Packaging unit: 10 piecespa
Reading head, RS-485 interface, without RS-485 termination resistor, RS-485 interface, Non-contact, absolute position encoder, Automatic detection of dirt accumulation, Output of position and speedfa
Read head, RS-485 interface, with RS-485 termination resistor, RS-485 interface, Non-contact, absolute position encoder, Automatic detection of dirt accumulation, Output of position and speedfa
Reading head, RS-485 interface, without RS-485 termination resistor, RS-485 interface, Non-contact, absolute position encoder, Automatic detection of dirt accumulation, Output of position and speedfa
Read head, RS-485 interface, with RS-485 termination resistor, RS-485 interface, Non-contact, absolute position encoder, Automatic detection of dirt accumulation, Output of position and speedfa
306 mm x 306 mm x 200 mm, 316L Stainless Steel, Ex e, Ex ia and Ex tb certified, Installation in Zone 1, Zone 2, Zone 21 and Zone 22, Straight Edge Sealing, No Gland Plate, Customizable configuration of terminals, cable entries and cable gland types as per specification, Explosion protection: Ex e, Enclosure: 1.5 mm AISI 316L, (1.4404) stainless steelpa
380 mm x 260 mm x 200 mm, 316L Stainless Steel, Ex e, Ex ia and Ex tb certified, Installation in Zone 1, Zone 2, Zone 21 and Zone 22, Straight Edge Sealing, No Gland Plate, Customizable configuration of terminals, cable entries and cable gland types as per specification, Explosion protection: Ex e, Enclosure: 1.5 mm AISI 316L, (1.4404) stainless steelpa
Ej tillgänglig för köp: For 8 modules, 24 V DC supply, Supported signal types: DI/DO/AI/TI/AO, Hazardous area: screw terminals, blue, Non-hazardous area: screw terminals, black, Number of modules: 8, Number of channels per module: 2 , 4, Signal type: Universal, Manufacturer: Universal, Control system type: Universalpa
Ej tillgänglig för köp: 1-channel isolated barrier, 230 V AC supply, Dry contact or NAMUR inputs, Relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC/EN 61508 / IEC/EN 61511, Housing width: 20 mm, Number of channels: 1-channel, Safety Integrity Level (SIL): SIL 2, Rated voltage: 207 ... 253 V AC, 45 ... 65 Hz, Field device: NAMUR sensor, Field device [2]: volt-free contact, Line fault detection, Type: 1 x relay (change-over contact), Reversible mode of operationpa
Ej tillgänglig för köp: 1-channel isolated barrier, 24 V DC supply (Power Rail), Thermocouple, RTD, potentiometer or voltage input, Voltage output 0/1 V ... 5 V, Configurable by PACTware, Line fault (LFD) and sensor burnout detection, Up to SIL 2 acc. to IEC/EN 61508 / IEC/EN 61511, Housing width: 20 mm, Number of channels: 1-channel, Safety Integrity Level (SIL): SIL 2, Rated voltage: 20 ... 30 V DC, Type: 2-wire connection, Type [2]: 3-wire connection, Type [3]: 4-wire connection, Field device: resistance thermometerpa
Ej tillgänglig för köp: 1-channel isolated barrier, 115 V AC supply, Dry contact or NAMUR inputs, Relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC/EN 61508 / IEC/EN 61511, Housing width: 20 mm, Number of channels: 1-channel, Safety Integrity Level (SIL): SIL 2, Rated voltage: 103.5 ... 126 V AC , 45 ... 65 Hz, Field device: NAMUR sensor, Field device [2]: volt-free contact, Line fault detection, Type: 1 x relay (change-over contact), Reversible mode of operationpa
Ej tillgänglig för köp: 1-channel isolated barrier, 115 V AC supply, Dry contact or NAMUR inputs, Relay contact output, Fault relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC/EN 61508 / IEC/EN 61511, Housing width: 20 mm, Number of channels: 1-channel, Safety Integrity Level (SIL): SIL 2, Rated voltage: 103.5 ... 126 V AC , 45 ... 65 Hz, Field device: NAMUR sensor, Field device [2]: volt-free contact, Line fault detection, Type: 2 x relay (change-over contact)pa
Ej tillgänglig för köp: 1-channel isolated barrier, 230 V AC supply, Dry contact or NAMUR inputs, Relay contact output, Fault relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC/EN 61508 / IEC/EN 61511, Housing width: 20 mm, Number of channels: 1-channel, Safety Integrity Level (SIL): SIL 2, Rated voltage: 207 ... 253 V AC, 45 ... 65 Hz, Field device: NAMUR sensor, Field device [2]: volt-free contact, Line fault detection, Type: 2 x relay (change-over contact)pa
Ej tillgänglig för köp: 2-channel isolated barrier, 230 V AC supply, Dry contact or NAMUR inputs, Relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC/EN 61508 / IEC/EN 61511, Housing width: 20 mm, Number of channels: 2-channel, Safety Integrity Level (SIL): SIL 2, Rated voltage: 207 ... 253 V AC, 45 ... 65 Hz, Field device: NAMUR sensor, Field device [2]: volt-free contact, Line fault detection, Type: 2 x relay (change-over contact), Reversible mode of operationpa
Ej tillgänglig för köp: 2-channel isolated barrier, 24 V DC supply (loop powered), Output 45 mA at 15 V DC, Test pulse immunity, Up to SIL 3 acc. to IEC/EN 61508, Housing width: 20 mm, Number of channels: 2-channel, Safety Integrity Level (SIL): SIL 3, Systematic capability (SC): SC 3, Rated voltage: 18 ... 30 V DC , loop powered, Type: field device supply, Test pulse immunity, Field device: 2 x Valve, Field device [2]: 2 x audible alarm, Field device [3]: 2 x visual alarm, Voltage: ≥ 15 Vpa
Ej tillgänglig för köp: 2-channel isolated barrier, 24 V DC supply (bus or loop powered), Output 45 mA at 10 V DC, Line fault transparency (LFT), Test pulse immunity, Up to SIL 3 acc. to IEC/EN 61508, Housing width: 20 mm, Number of channels: 2-channel, Line fault transparency, Safety Integrity Level (SIL): SIL 3, Systematic capability (SC): SC 3, Rated voltage: 18 ... 30 V DC, Type: logic input, Type [2]: field device supply, Test pulse immunity, Field device: 2 x Valve, Field device [2]: 2 x audible alarmpa
Ej tillgänglig för köp: 2-channel isolated barrier, 24 V DC supply (bus or loop powered), Output 45 mA at 12 V DC, Line fault transparency (LFT), Test pulse immunity, Up to SIL 3 acc. to IEC/EN 61508, Housing width: 20 mm, Number of channels: 2-channel, Line fault transparency, Safety Integrity Level (SIL): SIL 3, Systematic capability (SC): SC 3, Rated voltage: 18 ... 30 V DC, Type: logic input, Type [2]: field device supply, Test pulse immunity, Field device: 2 x Valve, Field device [2]: 2 x audible alarmpa
InterfacetechnologyfromPepperl+Fuchsoffersawiderangeofcomponentsandsolutionsforhazardousareaapplications in processíndustries ... amplifiersKFU8-SR-Ex* featureseveralhighlightsatonce: supplywith19to30VDCor90to253VAC, use in intrinsicallysafeapplications, andclassificationforsafetyapplicationsuptoSIL2. IntelligentSafetyRelayswithDiagnosticsandLFTToensure ...
Pepperl+FuchsLoRaWAN-baseradeultraljudssensorWILSEN är en robustlösning för mätning av fyllnadsnivå och avstånd ... avloppsvattenmodeller. Läs mer (endast på tyska) LoRaPark i Ulm Med ”LoRaPark” har stadenUlmskapat en plats där sensorbaseradelösningar för InternetofThings kan upplevas och görastillgängliga för alla medborgare. Med hjälp av WILSENdemonstrerasdetektion ...
Läs mer om säkra, absolutalinjärapositioneringssystem från Pepperl+Fuchs med säkerhetstillämpningar på upp till SIL3 och PLe ... kontrollsystemet. Förutomsäkrapositions- och hastighetsvärdensamt icke-säkradata, matar den även ut diagnostiskadata. Eftersom kodtejpen kan vara upp till 10000mlång är safePXV/PUSsärskiltlämplig för långaavstånd som kräversäkerabsolutpositionering ...
Automatiskadörrar, hissar, rulltrappor, barriärer eller kollektivtrafik; sensorerna från Pepperl+Fuchssortimentlämpar sig för en mängd olika tillämpningar inom entréautomation ... människor. MotionScan är en kombineradsensor med ett radardetekteringsfält på 4x4m som i ett tidigt skedekänner av personer som närmar sig så att dörren kan öppnas i tid. En inbyggdaktivinfrarödskannergerytterligareskydd mot kollisioner med dörren ...
Gå till ”funktionssäkerhetsnavet” hosPepperl+Fuchs, där du kan hittasäkerhetsbedömdaenheter för tillämpningar inom fabriksautomation och dessutom få åtkomst till praktiskaverktyg och broschyrer ... styrdafordon upp till SIL3/PLe med en endasensor. Denna säkerhetsversion är baserad på en kombination av ett 2D-läshuvud och ett flerfärgatband med DataMatrix-kod . Den inbyggdaprogramvarankontrollerarrimligheten för X-positionsvärdena med hjälp ...
1-5/916Items Per Page:
No results found?
Hint: Use wildcard character * before your search term, modify your search, check your search terms for misspellings, or contact us with your specific request.