Go to global website
2 adjustable trip values, 2 relay outputs, Operation via keypad, Characteristic programmable via 12 interpolation points, Resetting the outputs, automatic, manual or with external signal, Operating voltage: 10 ... 30 V DC, Relay: changeover contact, Dimensions: 96 mm x 48 mm x 102 mm
2 adjustable trip values, 2 relay outputs, Operation via keypad, Characteristic programmable via 12 interpolation points, Resetting the outputs, automatic, manual or with external signal, Operating voltage: 90 ... 260 V AC, Relay: changeover contact, Dimensions: 96 mm x 48 mm x 102 mm
8-channel, Inputs Ex ia, Installation in suitable enclosures in Zone 1, Module can be exchanged under voltage (hot swap), Explosion protection: Ex ia, Connection: NAMUR sensor, Connection [2]: volt-free contact
4-channel, Inputs Ex ia, Installation in suitable enclosures in Zone 1, Module can be exchanged under voltage (hot swap), Explosion protection: Ex ia, Field device: pressure converter, Field device [2]: flow converter, Field device [3]: level converter, Field device [4]: Temperature Converter, Connection: 2-wire transmitter, Connection [2]: 3-wire transmitter, Connection [3]: 4-wire transmitter, HART communication
4-channel, Inputs Ex ia, Installation in suitable enclosures in Zone 1, Module can be exchanged under voltage (hot swap), Explosion protection: Ex ia, Field device: resistance thermometer, Field device [2]: slide-wire sensors, Field device [3]: potentiometer, Connection: 2-wire sensor, Connection [2]: 3-wire sensor, Connection [3]: 4-wire sensor
4-channel, Inputs Ex ia, Outputs Ex ia, Installation in suitable enclosures in Zone 1, Module can be exchanged under voltage (hot swap), Explosion protection: Ex ia, Field device: pressure converter, Field device [2]: flow converter, Field device [3]: level converter, Field device [4]: Temperature Converter, Connection: 2-wire transmitter, HART communication
Interface between the I/O modules and the PCS/PLC, Com unit for 80 analog or 184 digital channels, Communication via PROFIBUS DP, Installation in suitable enclosures in Zone 1, Fieldbus type: PROFIBUS DP/DP-V1
Power supply for 24 V DC, Installation in suitable enclosures in Zone 1, Module can be exchanged under voltage (hot swap), Voltage: 5.4 V DC +/- 5% , , 12 V DC + 4/- 2%
Active termination of the fieldbus and passive termination of the service bus, Installation in suitable enclosures in Zone 1, Module can be exchanged under voltage in Zone 1 (hot swap; be aware bus operation may be affected)
Fieldbus diagnostic handheld for comprehensive diagnostics of the fieldbus physical layer, Comprehensive diagnostics for the fieldbus physical layer, Handheld with display and integrated expert system, Fieldbus interface Ex ia, FISCO, Entity, and DART, For commissioning, online monitoring and troubleshooting, For FOUNDATION Fieldbus H1 and PROFIBUS PA, IECEx approval, Dust protection, Europe
Connection board for K-System HART Multiplexer, 16-channel, Interface for series connection or parallel connection, Integrated, switchable 220 Ω resistor, Connection via screw terminals
Fieldbus power supply, module for fieldbus power hub, Output: 21 ... 23 V/500 mA, Voltage limitation for Entity ic and Ex nL, With galvanic isolation, Installation in Zone 2/Class I, Div. 2, For FOUNDATION Fieldbus H1 and PROFIBUS PA, IECEx approval, International, Europe, USA, Canada, Device coupler location: Zone 2 - high-power trunk, Instrument location / spur protection: Zone 2 - all relevant types of protection, Function: Fieldbus Power Supply
Fieldbus power supply, module for fieldbus power hub, Output: 28 ... 30 V/500 mA, High-power trunk for high device count and long cable lengths, With galvanic isolation, Installation in Zone 2/Class I, Div. 2, For FOUNDATION Fieldbus H1 and PROFIBUS PA, IECEx approval, International, Europe, USA, Canada, Device coupler location: non-explosion hazardous area, Zone 2 - high-power trunk, Zone 1 - high-power trunk, Division 2 - high-power trunk, Division 1 - high-power trunk
Advanced diagnostic module, plug-in module for the fieldbus power hub, Comprehensive diagnostics for fieldbus physical layer and power supply, Plug-in Module for the FieldConnex Power Hub, Precise measurements through passive circuits, For commissioning, online monitoring and troubleshooting, For FOUNDATION Fieldbus H1 and PROFIBUS PA, IECEx approval, International, Europe, USA, Canada
Basic diagnostic module, base module for fieldbus power hub physical layer diagnostics, Basic monitoring for power supply output and health, Plug-in Module for the FieldConnex Power Hub, Plug and play - no engineering required, For online monitoring, For FOUNDATION Fieldbus H1 and PROFIBUS PA, IECEx approval, International, Europe, USA, Canada
2 x 16-channel, 24 V DC supply, Suitable for HART communication, Dual RS 485 connections, Used with HiC Termination Boards, LED indicator for supply status, Splitting: 2 x 16
4 x 8-channel, 24 V DC supply, Suitable for HART communication, Dual RS 485 connections, Used with HiC Termination Boards, LED indicator for supply status, Splitting: 4 x 8
32-channel, 24 V DC supply, HART field device input (revision 5 to 7), RS-485 interface, Up to SIL 3 acc. to IEC/EN 61508
32-channel, 24 V DC supply, Interface for serial or parallel wiring options, Dual RS 485 connections, Slot for HART Multiplexer, Number of channels: 32 unbalanced signal loops
IDENTControl Compact RFID evaluation unit with EtherCAT interface
IDENTControl RFID control interface with multiprotocol Ethernet interface
Modbus Gateway 4-port DIN Rail DB9
Modbus Gateway 1-port DIN Rail DB9
Modbus Gateway 1-port DIN Rail Screw Terminal
PROFINET IO Gateway 4-port DIN Rail DB9
PROFINET IO Gateway 1-port DIN Rail DB9
PROFINET IO Gateway 1-port DIN Rail Screw Terminal
Device Server 32-port rack mount RJ45
Device Server 4-port DIN Rail DB9
Device Server 4-port panel mount DB9
Serial Device Server 1-port DIN Rail DB9
Serial Device Server 1-port Panel Mount DB9
Ethernet IO-Link module with eight IO-Link ports
EtherNet/IP IO-Link master with 8 inputs/outputs
PROFINET IO IO-Link master with 8 inputs/outputs
Ethernet unmanaged switch with 4 RJ45 gigabit ports, one gigabit SFP slot and fault alarm
UHF RFID read/write device with IO-Link interface
Counter/Timer/Tachometer, Adding/subtracting via 2 separate inputs, Batch controller with 2 pre-selections, Easy-to-read backlit 2-line LCD display with icons for the displayed preselection and the status of both outputs, Multicolor display, Operating voltage: 90 ... 260 V AC, Relay: changeover contact , Make contact, Output I: Relay with make contact, NC or NO progr., Output II: Relay with changeover contact, Dimensions: 48 mm x 48 mm x 109.8 mm
Counter/Timer/Tachometer, Adding/subtracting via 2 separate inputs, Batch controller with 2 pre-selections, Easy-to-read backlit 2-line LCD display with icons for the displayed preselection and the status of both outputs, Multicolor display, Operating voltage: 10 ... 30 V DC, Relay: changeover contact , Make contact, Output I: Relay with make contact, NC or NO progr., Output II: Relay with changeover contact, Dimensions: 48 mm x 48 mm x 109.8 mm
Counter/Timer/Tachometer, Adding/subtracting via 2 separate inputs, Batch controller with 2 pre-selections, 2 potential-free optocoupler outputs, Easy-to-read 2-line LCD display, color, with icons for the displayed preselection and the status of both outputs, Operating voltage: 90 ... 260 V AC, Optocoupler: Schaltleistung 30 V DC / 10 mA, Dimensions: 48 mm x 48 mm x 109.8 mm
Counter/Timer/Tachometer, Adding/subtracting via 2 separate inputs, Batch controller with 2 pre-selections, 2 potential-free optocoupler outputs, Easy-to-read 2-line LCD display, color, with icons for the displayed preselection and the status of both outputs, Operating voltage: 10 ... 30 V DC, Optocoupler: Schaltleistung 30 V DC / 10 mA, Dimensions: 48 mm x 48 mm x 109.8 mm
Single-channel terminal amplifier with line breakage detection, input for NAMUR sensors, DC 24 V supply voltage, standardized interface to prevent signal transmission errors, switching state display, LED yellow
Relay output with 1 pole, yellow LED indicates switching state, Free-wheeling diode, Compact terminal housing, Clips onto standard 35 mm rail to DIN EN 50 022, Degree of protection IP20, Operating voltage: 24 V DC ± 15 %, Connectable sensor types: PNP or NPN 3-wire sensors, Relay: 1 changeover contact
1-channel signal conditioner, 24 V DC supply (Power Rail), Dry contact or NAMUR input, 2 passive transistor outputs, Usable as signal splitter (1 input and 2 outputs), Reversible mode of operation, Line fault detection (LFD), Housing width 12.5 mm, Up to SIL 2 (SC 3) acc. to IEC/EN 61508, Housing width: 12.5 mm, Number of channels: 1-channel, Safety Integrity Level (SIL): SIL 2, Systematic capability (SC): SC 3, Rated voltage: 19 ... 30 V DC, Field device: NAMUR sensor, Field device [2]: volt-free contact
2-channel signal conditioner, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, 2 passive transistor outputs, Reversible mode of operation, Line fault detection (LFD), Housing width 12.5 mm, Up to SIL 2 (SC 3) acc. to IEC/EN 61508, Housing width: 12.5 mm, Number of channels: 2-channel, Safety Integrity Level (SIL): SIL 2, Systematic capability (SC): SC 3, Rated voltage: 19 ... 30 V DC, Field device: NAMUR sensor, Field device [2]: volt-free contact, Line fault detection
1-channel signal conditioner, 24 V DC supply (Power Rail), Input for 2-wire SMART transmitters and current sources, Signal splitter (1 input and 2 outputs), Dual output 0/4 mA ... 20 mA or 0/1 V ... 5 V, Terminal blocks with test sockets, Up to SIL 2 (SC 3) acc. to IEC/EN 61508, Housing width: 12.5 mm, Number of channels: 1-channel, HART communication, Test sockets, Safety Integrity Level (SIL): SIL 2, Systematic capability (SC): SC 3, Rated voltage: 19 ... 30 V DC
1-channel signal conditioner, 24 V DC supply (Power Rail), Thermocouple, RTD, potentiometer or voltage input, Current output 0/4 mA ... 20 mA, Sink or source mode, Configurable by PACTware, Line fault (LFD) and sensor burnout detection, Up to SIL 2 acc. to IEC/EN 61508 / IEC/EN 61511, Housing width: 12.5 mm, Number of channels: 1-channel, Safety Integrity Level (SIL): SIL 2, Rated voltage: 19 ... 30 V DC, Field device: resistance thermometer, Field device [2]: Thermocouple
1-channel signal conditioner, 230 V AC supply, Level sensing input, Adjustable range 5 kΩ ... 150 kΩ, Relay contact output, Minimum/maximum control, Housing width: 20 mm, Number of channels: 1-channel, Conductivity measurement, Min./max. control, Rated voltage: 207 ... 253 V AC, 45 ... 65 Hz, Signal: Resistance, Type: 1 x relay (change-over contact)
1-channel signal conditioner, 230 V AC supply, Level sensing input, Adjustable range 1 kΩ ... 150 kΩ, Relay contact output, Fault relay contact output, Adjustable time delay up to 10 s, Minimum/maximum control, Line fault detection (LFD), Housing width: 20 mm, Number of channels: 1-channel, Conductivity measurement, Min./max. control, Time delay, Rated voltage: 207 ... 253 V AC, 45 ... 65 Hz, Signal: Resistance, Line fault detection, Type: 2 x relay (change-over contact)
49 / 2731
Are you looking for more information? Feel free to learn more on our related pages.
Get a read of latest news and applications on your selected products.