Segment protector, junction box for fieldbus with short-circuit protection, Field junction box, module for DIN rail mounting, 12 increased safety outputs (Ex e), Short circuit current limitation per output, Segment Protector in Zone 1/Div. 2, Instruments in Zone 1/Div. 1, For FOUNDATION Fieldbus H1 and PROFIBUS PA, IECEx approval, Europe, Device coupler location: Zone 1 - high-power trunk, Instrument location / spur protection: Zone 1 - increased safety, Function: Device coupler
Segment protector, junction box for fieldbus with short-circuit and fault protection, field junction box, stand-alone device in aluminum housing for field installation, 4 ... 10 outputs Ex ic (FISCO or Entity), Advanced fault isolation at the spur, Segment Protector in Zone 2, Instruments in Zone 2 or Zone 1, For FOUNDATION Fieldbus H1 and PROFIBUS PA, IECEx approval, Dust protection, International, Europe, USA, Canada, Device coupler location: Zone 2 - high-power trunk
4 ... 12 outputs Ex ic (FISCO or Entity), Glass fiber reinforced polyester, impact resistant, IP66, Configurable cable entries for trunk and spurs, International approvals, For FOUNDATION Fieldbus H1 and PROFIBUS PA, Device coupler location: non-explosion hazardous area, Zone 2 - high-power trunk, Device coupler location [2]: Zone 2 - high-power trunk, Instrument location / spur protection: non-explosion hazardous area, Zone 2 - all relevant types of protection, Zone 1 - increased safety
Segment Protector Junction Box, Brushed Stainless Steel, 4 ... 12 outputs Ex ic (FISCO or Entity), Brushed enclosure, IP66, Configurable cable entries for trunk and spurs, International approvals, For FOUNDATION Fieldbus H1 and PROFIBUS PA, Device coupler location: non-explosion hazardous area, Zone 2 - high-power trunk, Device coupler location [2]: Zone 2 - high-power trunk
Connection of Ex d certified devices, Glass fiber reinforced polyester, impact resistant, IP66, Configurable cable entries for trunk and spurs, International approvals, For FOUNDATION Fieldbus H1 and PROFIBUS PA, Device coupler location: Zone 1 - high-power trunk, Instrument location / spur protection: Zone 1 - increased safety, Function: Device coupler, Design / Mounting: Outside installation
Segment Protector Junction Box, Brushed Stainless Steel, Connection of Ex d certified devices, Brushed enclosure, IP66, Configurable cable entries for trunk and spurs, International approvals, For FOUNDATION Fieldbus H1 and PROFIBUS PA, Device coupler location: Zone 1 - high-power trunk, Instrument location / spur protection: Zone 1 - increased safety, Function: Device coupler, Design / Mounting: Outside installation
Segment protector, junction box for fieldbus with short-circuit and fault protection, field junction box, electronic component for control cabinet installation, 4 ... 12 outputs Ex ic (FISCO or Entity) or non-incendive (Div 2), Advanced fault isolation at the spur, Segment Protector in Zone 2/Div. 2, Instruments in Zone 2/Div. 2 or Zone 1/Div. 1, For FOUNDATION Fieldbus H1 and PROFIBUS PA, IECEx approval, International, Europe, USA, Canada
Intrinsically safe (Ex ic)/non-incendive outputs, Anodized aluminum, IP67, Configurable cable entries for trunk and spurs, Packaged solution, For FOUNDATION Fieldbus H1 and PROFIBUS PA, USA, Canada, Device coupler location: Division 2 - high-power trunk, Instrument location / spur protection: Division 2 - all relevant types of protection, Function: Device coupler, Design / Mounting: Outside installation
Intrinsically safe (Ex ic)/non-incendive outputs, Carbon steel, NEMA 4, Configurable cable entries for trunk and spurs, Packaged solution, For FOUNDATION Fieldbus H1 and PROFIBUS PA, USA, Canada, Device coupler location: Division 2 - high-power trunk, Instrument location / spur protection: Division 2 - all relevant types of protection, Function: Device coupler, Design / Mounting: Outside installation
Intrinsically safe (Ex ic)/non-incendive outputs, Glass fiber reinforced polyester, NEMA 4x, Configurable cable entries for trunk and spurs, Packaged solution, For FOUNDATION Fieldbus H1 and PROFIBUS PA, USA, Canada, Device coupler location: Division 2 - high-power trunk, Instrument location / spur protection: Division 2 - all relevant types of protection, Function: Device coupler, Design / Mounting: Outside installation
Intrinsically safe (Ex ic)/non-incendive outputs, Impact resistant polycarbonate, NEMA 4x, Configurable cable entries for trunk and spurs, Packaged solution, For FOUNDATION Fieldbus H1 and PROFIBUS PA, USA, Canada, Device coupler location: Division 2 - high-power trunk, Instrument location / spur protection: Division 2 - all relevant types of protection, Function: Device coupler, Design / Mounting: Outside installation
Intrinsically safe (Ex ic)/non-incendive outputs, Stainless steel, brushed NEMA 4x, Configurable cable entries for trunk and spurs, Packaged solution, For FOUNDATION Fieldbus H1 and PROFIBUS PA, USA, Canada, Device coupler location: Division 2 - high-power trunk, Instrument location / spur protection: Division 2 - all relevant types of protection, Function: Device coupler, Design / Mounting: Outside installation