轉至全球網站
Surge protection for 3 signal lines, Nominal voltage 1 V DC, Surge protection barrier for non-grounded signal lines, Max. surge current (8/20 µs) 20 kA, Connection via screw terminals, DIN rail mountable, Up to SIL 3 acc. to IEC/EN 61508, Modularity: one-piece, Number of protected signal lines: 3, Topology: non-grounded, Safety Integrity Level (SIL): SIL 3, Nominal voltage: 1 V DC, Nominal discharge current (8/20 µs): 5 kA per line (10x)
Surge protection for 3 signal lines, Nominal voltage 1 V DC, Surge protection barrier for grounded signal lines, Max. surge current (8/20 µs) 20 kA, Connection via screw terminals, DIN rail mountable, Up to SIL 3 acc. to IEC/EN 61508, Modularity: one-piece, Number of protected signal lines: 3, Topology: grounded, Safety Integrity Level (SIL): SIL 3, Nominal voltage: 1 V DC, Nominal discharge current (8/20 µs): 5 kA per line (10x)
Surge protection for 3 signal lines, Nominal voltage 24 V DC, Surge protection barrier for non-grounded signal lines, Max. surge current (8/20 µs) 20 kA, Connection via screw terminals, DIN rail mountable, Up to SIL 3 acc. to IEC/EN 61508, Modularity: one-piece, Number of protected signal lines: 3, Topology: non-grounded, Safety Integrity Level (SIL): SIL 3, Nominal voltage: 24 V DC, Nominal discharge current (8/20 µs): 5 kA per line (10x)
Surge protection for 3 signal lines, Nominal voltage 24 V DC, Surge protection barrier for grounded signal lines, Max. surge current (8/20 µs) 20 kA, Connection via screw terminals, DIN rail mountable, Up to SIL 3 acc. to IEC/EN 61508, Modularity: one-piece, Number of protected signal lines: 3, Topology: grounded, Safety Integrity Level (SIL): SIL 3, Nominal voltage: 24 V DC, Nominal discharge current (8/20 µs): 5 kA per line (10x)
Surge protection barrier for 2 signal lines, Nominal voltage 24 V DC, Surge protection barrier for non-grounded signal lines, Max. surge current (8/20 µs) 20 kA, Connection via screw terminals, DIN rail mountable, Up to SIL 3 acc. to IEC/EN 61508, Modularity: one-piece, Number of protected signal lines: 2, Topology: non-grounded, Safety Integrity Level (SIL): SIL 3, Nominal voltage: 24 V DC, Nominal discharge current (8/20 µs): 5 kA per line (10x)
Surge protection barrier for 2 signal lines, Nominal voltage 24 V DC, Surge protection barrier for grounded signal lines, Max. surge current (8/20 µs) 20 kA, Connection via screw terminals, DIN rail mountable, Up to SIL 3 acc. to IEC/EN 61508, Modularity: one-piece, Number of protected signal lines: 2, Topology: grounded, Safety Integrity Level (SIL): SIL 3, Nominal voltage: 24 V DC, Nominal discharge current (8/20 µs): 5 kA per line (10x)
Surge protection barrier for 2 signal lines, Nominal voltage 1 V DC, Surge protection barrier for non-grounded signal lines, Max. surge current (8/20 µs) 20 kA, Connection via screw terminals, DIN rail mountable, Up to SIL 3 acc. to IEC/EN 61508, Modularity: one-piece, Number of protected signal lines: 2, Topology: non-grounded, Safety Integrity Level (SIL): SIL 3, Nominal voltage: 1 V DC, Nominal discharge current (8/20 µs): 5 kA per line (10x)
Surge protection barrier for 2 signal lines, Nominal voltage 1 V DC, Surge protection barrier for non-grounded signal lines, Max. surge current (8/20 µs) 20 kA, Connection via spring terminals with push-in connection technology, DIN rail mountable, Up to SIL 3 acc. to IEC/EN 61508, Modularity: one-piece, Number of protected signal lines: 2, Topology: non-grounded, Safety Integrity Level (SIL): SIL 3, Nominal voltage: 1 V DC, Nominal discharge current (8/20 µs): 5 kA per line (10x)
Surge protection barrier for 2 signal lines, Nominal voltage 1 V DC, Surge protection barrier for grounded signal lines, Max. surge current (8/20 µs) 20 kA, Connection via screw terminals, DIN rail mountable, Up to SIL 3 acc. to IEC/EN 61508, Modularity: one-piece, Number of protected signal lines: 2, Topology: grounded, Safety Integrity Level (SIL): SIL 3, Nominal voltage: 1 V DC, Nominal discharge current (8/20 µs): 5 kA per line (10x)
Surge protection barrier for 2 signal lines, Nominal voltage 1 V DC, Surge protection barrier for grounded signal lines, Max. surge current (8/20 µs) 20 kA, Connection via spring terminals with push-in connection technology, DIN rail mountable, Up to SIL 3 acc. to IEC/EN 61508, Modularity: one-piece, Number of protected signal lines: 2, Topology: grounded, Safety Integrity Level (SIL): SIL 3, Nominal voltage: 1 V DC, Nominal discharge current (8/20 µs): 5 kA per line (10x)
Surge protection barrier for 2 signal lines, Nominal voltage 24 V DC, Surge protection barrier for non-grounded signal lines, Max. surge current (8/20 µs) 20 kA, Connection via spring terminals with push-in connection technology, DIN rail mountable, Up to SIL 3 acc. to IEC/EN 61508, Modularity: one-piece, Number of protected signal lines: 2, Topology: non-grounded, Safety Integrity Level (SIL): SIL 3, Nominal voltage: 24 V DC, Nominal discharge current (8/20 µs): 5 kA per line (10x)
Surge protection barrier for 2 signal lines, Nominal voltage 24 V DC, Surge protection barrier for grounded signal lines, Max. surge current (8/20 µs) 20 kA, Connection via spring terminals with push-in connection technology, DIN rail mountable, Up to SIL 3 acc. to IEC/EN 61508, Modularity: one-piece, Number of protected signal lines: 2, Topology: grounded, Safety Integrity Level (SIL): SIL 3, Nominal voltage: 24 V DC, Nominal discharge current (8/20 µs): 5 kA per line (10x)
For surge protection system M-LB-2000, Color black, DIN rail mountable
Surge protection for 2 signal lines, Nominal voltage 5 V, Surge protection barrier for non-grounded signal lines, Max. surge current (8/20 µs) 20 kA, Uninterruptable operation (auto reset), Status indication, Modular design, pluggable, Up to SIL 3 acc. to IEC/EN 61508, Modularity: two-piece, Number of protected signal lines: 2, Topology: non-grounded, Safety Integrity Level (SIL): SIL 3, Nominal discharge current (8/20 µs): 5 kA per line
Surge protection for 2 signal lines, Nominal voltage 5 V, Surge protection barrier for grounded signal lines, Max. surge current (8/20 µs) 20 kA, Uninterruptable operation (auto reset), Status indication, Modular design, pluggable, Up to SIL 3 acc. to IEC/EN 61508, Modularity: two-piece, Number of protected signal lines: 2, Topology: grounded, Safety Integrity Level (SIL): SIL 3, Nominal discharge current (8/20 µs): 5 kA per line
Surge protection for 2 signal lines, Nominal voltage 12 V, Surge protection barrier for non-grounded signal lines, Max. surge current (8/20 µs) 20 kA, Uninterruptable operation (auto reset), Status indication, Modular design, pluggable, Up to SIL 3 acc. to IEC/EN 61508, Modularity: two-piece, Number of protected signal lines: 2, Topology: non-grounded, Safety Integrity Level (SIL): SIL 3, Nominal discharge current (8/20 µs): 5 kA per line
Protection module for 2 signal lines, Nominal voltage 12 V, Protection module for non-grounded signal lines, Max. surge current (8/20 µs) 20 kA, Uninterruptable operation (auto reset), Status indication, Mounting on base module, pluggable, Up to SIL 3 acc. to IEC/EN 61508, Number of protected signal lines: 2, Topology: non-grounded, Safety Integrity Level (SIL): SIL 3, Nominal discharge current (8/20 µs): 5 kA per line
Surge protection for 2 signal lines, Nominal voltage 12 V, Surge protection barrier for grounded signal lines, Max. surge current (8/20 µs) 20 kA, Uninterruptable operation (auto reset), Status indication, Modular design, pluggable, Up to SIL 3 acc. to IEC/EN 61508, Modularity: two-piece, Number of protected signal lines: 2, Topology: grounded, Safety Integrity Level (SIL): SIL 3, Nominal discharge current (8/20 µs): 5 kA per line
Surge protection for 2 signal lines, Nominal voltage 24 V, Surge protection barrier for non-grounded signal lines, Max. surge current (8/20 µs) 20 kA, Uninterruptable operation (auto reset), Status indication, Modular design, pluggable, Up to SIL 3 acc. to IEC/EN 61508, Modularity: two-piece, Number of protected signal lines: 2, Topology: non-grounded, Safety Integrity Level (SIL): SIL 3, Nominal discharge current (8/20 µs): 5 kA per line
Protection module for 2 signal lines, Nominal voltage 24 V, Protection module for non-grounded signal lines, Max. surge current (8/20 µs) 20 kA, Uninterruptable operation (auto reset), Status indication, Mounting on base module, pluggable, Up to SIL 3 acc. to IEC/EN 61508, Number of protected signal lines: 2, Topology: non-grounded, Safety Integrity Level (SIL): SIL 3, Nominal discharge current (8/20 µs): 5 kA per line
Surge protection for 2 signal lines, Nominal voltage 24 V, Surge protection barrier for grounded signal lines, Max. surge current (8/20 µs) 20 kA, Uninterruptable operation (auto reset), Status indication, Modular design, pluggable, Up to SIL 3 acc. to IEC/EN 61508, Modularity: two-piece, Number of protected signal lines: 2, Topology: grounded, Safety Integrity Level (SIL): SIL 3, Nominal discharge current (8/20 µs): 5 kA per line
Protection module for 2 signal lines, Nominal voltage 24 V, Protection module for grounded signal lines, Max. surge current (8/20 µs) 20 kA, Uninterruptable operation (auto reset), Status indication, Mounting on base module, pluggable, Up to SIL 3 acc. to IEC/EN 61508, Number of protected signal lines: 2, Topology: grounded, Safety Integrity Level (SIL): SIL 3, Nominal discharge current (8/20 µs): 5 kA per line
Surge protection for 2 signal lines, Nominal voltage 48 V, Surge protection barrier for non-grounded signal lines, Max. surge current (8/20 µs) 20 kA, Uninterruptable operation (auto reset), Status indication, Modular design, pluggable, Up to SIL 3 acc. to IEC/EN 61508, Modularity: two-piece, Number of protected signal lines: 2, Topology: non-grounded, Safety Integrity Level (SIL): SIL 3, Nominal discharge current (8/20 µs): 5 kA per line
Surge protection for 2 signal lines, Nominal voltage 48 V, Surge protection barrier for grounded signal lines, Max. surge current (8/20 µs) 20 kA, Uninterruptable operation (auto reset), Status indication, Modular design, pluggable, Up to SIL 3 acc. to IEC/EN 61508, Modularity: two-piece, Number of protected signal lines: 2, Topology: grounded, Safety Integrity Level (SIL): SIL 3, Nominal discharge current (8/20 µs): 5 kA per line
Protection module for 2 signal lines, Nominal voltage 48 V, Protection module for grounded signal lines, Max. surge current (8/20 µs) 20 kA, Uninterruptable operation (auto reset), Status indication, Mounting on base module, pluggable, Up to SIL 3 acc. to IEC/EN 61508, Number of protected signal lines: 2, Topology: grounded, Safety Integrity Level (SIL): SIL 3, Nominal discharge current (8/20 µs): 5 kA per line
Surge protection for 2 signal lines, Nominal voltage 180 V, Surge protection barrier for non-grounded signal lines, Max. surge current (8/20 µs) 12.5 kA, Uninterruptable operation (auto reset), Status indication, Modular design, pluggable, Up to SIL 3 acc. to IEC/EN 61508, Modularity: two-piece, Number of protected signal lines: 2, Topology: non-grounded, Safety Integrity Level (SIL): SIL 3, Nominal discharge current (8/20 µs): 5 kA per line
Protection module for 2 signal lines, Nominal voltage 180 V, Protection module for non-grounded signal lines, Max. surge current (8/20 µs) 12.5 kA, Uninterruptable operation (auto reset), Status indication, Mounting on base module, pluggable, Up to SIL 3 acc. to IEC/EN 61508, Number of protected signal lines: 2, Topology: non-grounded, Safety Integrity Level (SIL): SIL 3, Nominal discharge current (8/20 µs): 5 kA per line
Surge protection for 2 signal lines, Nominal voltage 230 V, Surge protection barrier for non-grounded signal lines, Max. surge current (8/20 µs) 6 kA, Uninterruptable operation (auto reset), Status indication, Modular design, pluggable, Up to SIL 3 acc. to IEC/EN 61508, Modularity: two-piece, Number of protected signal lines: 2, Topology: non-grounded, Safety Integrity Level (SIL): SIL 3, Nominal discharge current (8/20 µs): 3 kA per line
Monitoring of up to 50 surge protection barriers, Two-part monitoring device, Device set with transmitter/receiver and reverse unit, Fault indication via LED, Status indication output, Modularity: two-piece, Display elements: status display , operating state (green), fault indication (red), Device suitable for mounting in equipment protection level: Gc
For surge protection system M-LB-4000, Isolation acc. to IEC 60079-11, Color blue, DIN rail mountable
Protection module for 2 signal lines, Nominal voltage 5 V, Protection module for non-grounded signal lines, Max. surge current (8/20 µs) 20 kA, Uninterruptable operation (auto reset), Status indication, Mounting on base module, pluggable, Up to SIL 3 acc. to IEC/EN 61508, Number of protected signal lines: 2, Topology: non-grounded, Safety Integrity Level (SIL): SIL 3, Nominal discharge current (8/20 µs): 5 kA per line
Protection module for 2 signal lines, Nominal voltage 5 V, Protection module for grounded signal lines, Max. surge current (8/20 µs) 20 kA, Uninterruptable operation (auto reset), Status indication, Mounting on base module, pluggable, Up to SIL 3 acc. to IEC/EN 61508, Number of protected signal lines: 2, Topology: grounded, Safety Integrity Level (SIL): SIL 3, Nominal discharge current (8/20 µs): 5 kA per line
Protection module for 2 signal lines, Nominal voltage 12 V, Protection module for grounded signal lines, Max. surge current (8/20 µs) 20 kA, Uninterruptable operation (auto reset), Status indication, Mounting on base module, pluggable, Up to SIL 3 acc. to IEC/EN 61508, Number of protected signal lines: 2, Topology: grounded, Safety Integrity Level (SIL): SIL 3, Nominal discharge current (8/20 µs): 5 kA per line
Surge protection for 2 signal lines, Nominal voltage 24 V, Surge protection barrier for non-grounded signal lines, Max. surge current (8/20 µs) 20 kA, High current version, Uninterruptable operation (auto reset), Status indication, Modular design, pluggable, Up to SIL 3 acc. to IEC/EN 61508, Modularity: two-piece, Number of protected signal lines: 2, Topology: non-grounded, Safety Integrity Level (SIL): SIL 3, Nominal discharge current (8/20 µs): 5 kA per line
Protection module for 2 signal lines, Nominal voltage 24 V, Protection module for non-grounded signal lines, Max. surge current (8/20 µs) 20 kA, High current version, Uninterruptable operation (auto reset), Status indication, Mounting on base module, pluggable, Up to SIL 3 acc. to IEC/EN 61508, Number of protected signal lines: 2, Topology: non-grounded, Safety Integrity Level (SIL): SIL 3, Nominal discharge current (8/20 µs): 5 kA per line
Protection module for 2 signal lines, Nominal voltage 48 V, Protection module for non-grounded signal lines, Max. surge current (8/20 µs) 20 kA, Uninterruptable operation (auto reset), Status indication, Mounting on base module, pluggable, Up to SIL 3 acc. to IEC/EN 61508, Number of protected signal lines: 2, Topology: non-grounded, Safety Integrity Level (SIL): SIL 3, Nominal discharge current (8/20 µs): 5 kA per line
Protection module for 2 signal lines, Nominal voltage 230 V, Protection module for non-grounded signal lines, Max. surge current (8/20 µs) 6 kA, Uninterruptable operation (auto reset), Status indication, Mounting on base module, pluggable, Up to SIL 3 acc. to IEC/EN 61508, Number of protected signal lines: 2, Topology: non-grounded, Safety Integrity Level (SIL): SIL 3, Nominal discharge current (8/20 µs): 3 kA per line
Surge protection for 4 communication lines, Surge protection for Ethernet infrastructure, Conductor connection via RJ45 sockets, Fully shielded design, Status indication, Housing width 19 mm, DIN rail mountable, Modularity: one-piece, Topology: non-grounded, Device suitable for mounting in equipment protection level: Gc
Mounting accessory for M-LB-4710 surge protection barrier, Enables the use of M-LB-4400 fault status module, Used for monitoring and remote messaging of the operating state
Surge protection for 4 communication lines, Surge protection for Ethernet infrastructure, Conductor connection via RJ45 sockets, Fully shielded design, Housing width 19 mm, DIN rail mountable, Modularity: one-piece, Topology: non-grounded
40 / 40