Seleccione su país
ICA-4IO-2M4-G20-B22A-P18 Motor Roller System Module
G20 MDR system module with 4 digital inputs/outputs and 2 connections for MDRs
Ventajas clave de un vistazo
- Connections for 24 V or 48 V DC roller motors
- Inputs for 2- and 3-wire sensors
- Electronic PNP outputs
- Function indicator for motors, inputs and outputs
- Mounting directly in the support profile
Mostrar más









Nota
Todos los documentos relacionados con los productos, como certificados, declaraciones de conformidad, etc., que se emitieron antes de la conversión con el nombre de Pepperl+Fuchs GmbH o Pepperl+Fuchs AG también se aplican a Pepperl+Fuchs SE.
EN
- EN
- DE
- FR
Datos técnicos de ICA-4IO-2M4-G20-B22A-P18
| Compatible roller motors | Interroll EC310 Interroll EC5000 24 V AI (20 W / 35 W / 50 W) Interroll EC5000 48 V AI (20 W / 35 W / 50 W) Rulmeca BL3 Itoh Denki PM500XK Itoh Denki PM500XC PULSEROLLER Senergy-IDC MTA MRD50 (A interface, 24 V to 40 W) MTA MRD50 (A interface, 48 V to 44 W) WWL R-*-H + CE23XX Conveline RM50 Mambaroll Built-In Drive Roller 50 UniDrive ONE |
| LED indication | Zone 1: MOT, IO1, IO2, X Zone 2: MOT, IO1, IO2, X L-A, L-B, PWR |
| Auxiliary voltage | UPWR | 18 ... 56 V DC PELV Max. 10 A Current limitation of the supply max. 30 A For UL: Z-type miniature circuit breaker in accordance with UL 1077, max. 20 A, required |
| Operating voltage | UB | 15 ... 30 V DC, PELV Powered from ICE-EP2-G20-4B22A-P17 |
| No-load supply current | I0 | ≤ 40 mA |
| Operating current | IB | max. 3 A |
| Interface type | proprietary system interface |
| Number/Type | 4 Inputs for 3-wire sensors (PNP), DC (Zone 1: IO1, IO2; Zone 2: IO1, IO2) | |
| Supply | from G20 Motor Roller System Module via L-A | |
| Current loading capacity | 200 mA per connection in Zone 1 (IO1, IO2) and Zone 2 (IO1, IO2) , overload and short-circuit protected | |
| Input current | ≤ 5 mA (limited internally) | |
| Switching point | Type 3 according to IEC 61131-2 |
| Number/Type | 4 electronic outputs, PNP (Zone 1:IO1, IO2; Zone 2: IO1, IO2), overload proof and short-circuit proof | |
| Supply | from G20 Motor Roller System Module via L-A | |
| Current | 200 mA per output |
| Number/Type | 2 outputs for DC roller motors (Zone 1: MOT, Zone 2: MOT) | |
| Supply | via UPWR | |
| Current loading capacity | 3.5 A (continuous), 5 A (< 2 s), max. 7.5 A (< 0.3 s) per motor Total current (continuous) max. 7 A per device | |
| Overload protection | Fuse 4 A, I2t = 122.5 A2s per motor | |
| Signal level | Speed: US = 0.3 … 10 V in no-load operation Ri = 5.6 kΩ, RLOAD ≥ 35 kΩ Direction of rotation: Digital output PNP UD low = high resistance UD high ≥ 12 V Ri = 5.6 kΩ, RLOAD ≥ 15 kΩ | |
| Fault level | Motor fault: Digital input NPN 0 (no error) ≥ 125 µA 1 (error) ≤ 25 µA |
| Electromagnetic compatibility | |||||
| |||||
| Degree of protection | EN 60529:2000 | |
| Input | EN 61131-2:2007 | |
| Emitted interference | EN 61000-6-4:2007 | |
| Noise immunity | EN 61000-6-2:2005 |
| UL approval | |||||
| |||||
| UL File Number | E223772 | ||||
| Ambient temperature | -25 ... 60 °C (-13 ... 140 °F) | |
| Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
| Relative humidity | 85 % non-condensing | |
| Climatic conditions | For indoor use only | |
| Altitude | ≤ 5000 m above MSL | |
| Shock and impact resistance | 30 g, 11 ms in 6 spatial directions, 3 shocks 10 g, 16 ms in 6 spatial directions, 1000 shocks | |
| Vibration resistance | 0.75 mm / 5 g 5 ... 500 Hz | |
| Pollution degree | 3 |
| Degree of protection | IP67 according to EN 60529 | ||||||||||
| Connection | 24 V/48 V power (PWR): Piercing technology, black or gray flat cable L-A; L-B: M12 round plug connector in accordance with EN 61076-2-101, LF type (4-pin, socket contacts, screw-locking, A-coded) Mating connector: LM type or similar Inputs/outputs (IO), motors (MOT): M8 round plug connector in accordance with EN 61076-2-104 IO: LF type (4-pin, bushing contacts, screw-locking, A-coded) Female connector: LM type or similar MOT: NF type (5-pin, bushing contacts, snap-locking, B-coded) Female connector: NM type or similar | ||||||||||
| Mass | 310 g | ||||||||||
| Dimensions | |||||||||||
| |||||||||||
| Mounting | 2 clips with ∅ 8 mm drill hole The module must be secured to a solid, continuous surface using the two lugs | ||||||||||
| Cable length | 1.5 m (L-A, L-B) 0.8 m (Zone 1, Zone 2: IO) 0.4 m (Zone 1, Zone 2: MOT) | ||||||||||
| Note | The flat cable routing is designed for 100 actuation cycles | ||||||||||
Páginas relacionadas